You are on page 1of 1

IPLImprovementtoexistingcorrodedrebar

INUVIL PUBLIC LIBRARY


DETAIL TO IMPROVE END ANCHORAGE OF THE COLUMN














LappingwithBeamcompression
reinforcement(30)
Existingbeamcompression
reinforcement
ExistingEmbeddedRebar
ExistingCorrodedRebar
NewRebarMatchto
Existingsize
ExistingBeam
ConstructionSequence
a. Tohackthetopcover(seefig.
portionhatched)oftheexisting
beamandexposethecompression
reinforcementofthebeam
(lappinglengthis30xdiameterof
thenewrebar)
b. Makesurethebeam
reinforcementisexposedandthe
rebariscleanenough
c. Weldthenewcolumnrebartothe
columnreinforcementwhile
maintainingtheprescribedlapping
length(Buttweldfulllength)
d. Afterfinishedtheweldingofall
thecolumnrebar,applyanti
corrosivematerialatleastone
coat
e. Finally,fillupthehackedportion
withnonshrinkgroutmaterial
Note:
Allabovementionedsequencearetobe
ensuredduringconstruction
Thismethodisapplicable,onlyifrebarsize
isless than25mm
Newbuttweldingto
thecolumnrebar