Cat 318C 330C Excavator

Electronic Control System Troubleshooting Chart


Symptoms Probable Causes Next Steps
No Operators Display

Engine and pump controller
internal circuit failure

Check status of the LED for red
If red, replace the
controller
If not red, troubleshoot
power supply to
operators monitor and
data link circuit

Open or short in the data link
circuit

Check communication between
engine and pump controller
and CAT ET

Check status of the LED for
yellow:
If yellow, troubleshoot data
link circuit (pull-up voltage
test)
If not yellow, troubleshoot
operators monitor

No Power supply to engine and
pump controller

Check status of LED for green:
If green, troubleshoot data
link circuit (pull-up voltage
test)
If not green, troubleshoot
power supply circuit
Check fuse
Check battery voltage

No Power supply to operators
monitor

Troubleshoot power supply to
operators monitor
Consider pull-up voltage test
on operators monitor on data
link circuit


Auto travel
does not shift to low

Faulty controller
(open or short in the output
driver transistor
of the engine and pump
controller)

Perform pull-up voltage test

Solenoid Failure

Check for active/logged fault
Perform device test on the
solenoid (amperage)

Faulty input(s)

Validate status of input signal
(status mode):
Pump pressure sensors
Travel pressure sensors

Cat 318C 330C Excavator
Electronic Control System Troubleshooting Chart
Incorrect Configuration setup
values

Validate configuration


1Touch low idle
does not function

Faulty input(s)

Validate status of input signal
(status mode)
1 touch low idle input
switch
Pump pressure sensors
Implement pressure
sensors

Faulty controller (open or short
in the output driver transistor
of the engine and pump
controller)

Perform pull-up voltage test on
input circuit

Incorrect configuration setup
values

Validate configuration