You are on page 1of 4

Xiamen Four-Faith Communication Technology Co., Ltd.

Add 44 3 J1-J2
http//www.fourfaith.com Tel 0592-6300320 Fax0592-5912735
1
Communication between F8114 and F8914
There are three node types in F8914,coordinator, routing and end device. There is one central node
in the ZigBee network. It can be the coordinator. There should be one coordinator in the ZigBee
network. PAN ID should be the same. Each ZigBee has node address, and the coordinator is 0.
Physical channel is suggested to be 15,20,25,26, to avoid interference with WIFI channels.
1. Configuration in F8114(Router)
Data Service Center Settings:
When you use zigbee funciton only, data center number is 0.
Use ZigBee
function only

Xiamen Four-Faith Communication Technology Co., Ltd.

Add 44 3 J1-J2
http//www.fourfaith.com Tel 0592-6300320 Fax0592-5912735
2
Zigbee Setting:
The same as F8914
The same as
F8914
Crossed configuration
with F8914

Xiamen Four-Faith Communication Technology Co., Ltd.

Add 44 3 J1-J2
http//www.fourfaith.com Tel 0592-6300320 Fax0592-5912735
3
2. Configuration in F8914
The debug level can be configure as 1 or 2 when you make the test, and the change to 0 when you
put it into use.
After configuration, repower F8114.
The same as F8114
The same as F8114
Crossed configuration
with F8114
The lower baudrate,
the longer interval

Xiamen Four-Faith Communication Technology Co., Ltd.

Add 44 3 J1-J2
http//www.fourfaith.com Tel 0592-6300320 Fax0592-5912735
4
F8914
F8114
Macy
Skype: tony-hsmshi
Email: macy@four-faith.com