7.

2 kV IEC Withdrawable Vacuum Contactor-Fuse Combination Truck


W-SLC Medium Voltage
fused contactor truck
A safe, reliable and efcient motor starter
2
Hydraulics
Powering
business
worldwide
Next generation
transportation
Eaton is driving the
development of new
technologies from hybrid
drivetrains and emission control
systems to advanced engine
components that reduce fuel
consumption and emissions in
trucks and cars.
Higher expectations
We continue to expand our
aerospace solutions and
services to meet the needs
of new aviation platforms,
including the high-ying light jet
and very light jet markets.
Building on our strengths
Our hydraulics business
combines localized service
and support with an innovative
portfolio of uid power
solutions to answer the needs
of global infrastructure projects,
including locks, canals and
dams.
Powering Greener Buildings
and Businesses
Eatons Electrical Group is
a leading provider of power
quality, distribution and control
solutions that increase energy
efciency and improve power
quality, safety and reliability.
Our solutions offer a growing
portfolio of green products
and services, such as energy
audits and real-time energy
consumption monitoring.
Eatons Uninterruptible Power
Supplies (UPS), variable-speed
drives and lighting controls help
conserve energy and increase
efciency.
Eaton delivers the power inside hundreds of products
that are answering the demands of todays fast changing
world.
We help our customers worldwide manage the power
they need for buildings, aircraft, trucks, cars, machinery
and entire businesses. And we do it in a way that
consumes fewer resources.
Automotive
Aerospace
Electrical
Truck
Hydraulics
Automotive
Aerospace
Electrical
Truck
Hydraulics
MV Switchgear Technology
is in our DNA
Complete Global Medium Voltage Switchgear Solutions
Eaton, a premier leader in designing and manufacturing power
distribution and protection equipment in the electrical industry,
offers a comprehensive range of medium voltage (MV) solutions
to meet the needs of virtually every application. From products
that feature cutting-edge design that allow for easy access,
maintenance and space savings, to arc-resistant products that
enhance safety, Eatons medium voltage solutions provide a
variety of products for every need. Additionally, Eatons global
service network provides maximum customer support in all
regions of the world.
As one of the few completely vertically integrated and diversied
industrial manufacturers in the world, Eaton designs not only MV
assemblies, but also the key components that comprise the MV
solutions from steel housing and circuit breaker compartments
to vacuum interrupters, circuit breakers, bus systems and fuses.
Eatons MV heritage, strengthened by acquisitions such as
Westinghouse DCBU, Cutler Hammer, MEM and Holec, has
resulted in breakthrough MV technologies and numerous
international patents over the years.
Integral to Eatons complete electrical PowerChain Solutions
which help businesses increase reliability, efciency and
safety Eatons medium voltage equipment meets all applicable
standards and certications such as IEC, NEMA / ANSI, GB, UL,
IEEE, KEMA and CSA.
When it comes to medium voltage solutions, you can trust the
one name with a long history of proven performance: Eaton.
3
Eaton Corporation is a worldwide leader in the
design, manufacture, and sale of safe, reliable
and high-performance medium voltage power
distribution equipment in accordance with IEC,
GB and ANSI standards.
4
Introduction
Developed on cutting-edge technologies, Eatons W-SLC withdrawable type
vacuum contactor-fuse combination units are world leading in terms of performance,
safety and functionality. The W-SLC vacuum contactor-fuse combination units are
applicable in AC systems with voltages up to 7.2 kV and 50/60 Hz. They can
be used in frequently operated heavy loads and harsh environments.
5
Product safety features

The contactor is prevented from closing and a panel
indication is provided when:
Fuse blown and or Fuse not tted
Additional interlock options are available to interface
with the panel if appropriate panel designs are incorporated
such that:
The truck is prevented from being racked in if:
- The front door is open
- The earth switch is ON
The earth switch cannot be switched ON if the truck is
in the Service Position.
The panel door cannot be opened if the truck is in
the Service Position.
Applications
W-SLC vacuum contactor-fuse combination
motor starting applications:
Squirrel-cage induction motors
Synchronous motors
Wound-rotor motors
Suitable for:
Full voltage starting
Reduced voltage starting
The perfect choice
for all applications
HVAC
Mining
Automotive
Petrochemical
Pulp and Paper
Pumps, Fans, Conveyors and Crushers
6
Utilization conditions
Eatons vacuum contactor-fuse combination units
are suitable for use in the following conditions:
Ambient temperatue: -15 C to +40 C
Relative humidity: max. 95%non-condensing
Altitude: up to 1000 m
Please contact Customer service for special requirements.


Design and testing standards

Eatons vacuum contactor-fuse combination
units are fully in line with IEC standards.
IEC 62271-200
IEC 60470
Key technical features
*
The ratings for new vacuum
contactor-fuse combination units:
Voltage: up to 7.2 kV
Current: Contactor continuous current: 400 A
Combination Continuous current: 200 A
Breaking: up to 50 kA with fuse
8500 A interrupting rating without fuse
Control voltages:
110, 220 50 Hz Vac
120, 240 60 Hz Vac
110, 120 Vdc
Service life:
300,000 electrical operations
1,000,000 mechanical operations

* For detailed information, please refer to technical data table
7
Dimensions
Eatons mid-mounted type withdrawable vacuum contactor-fuse combination units
Striker Pin length after fuse blown = 10 - 16mm
Maximum dimensions for fuse
8
Electrical operation
Wiring Diagram
Auxiliary contacts when the trolley is on
Test Position or connected Position
Note: The drawing is shown with the Contactor
Truck in the withdrawn Test Position,
de-energised, with fuses tted and healthy.
+Ve +Ve
-Ve
K1
K1
K1
Y1
-Ve
Q1
+Ve +Ve +Ve
+Ve +Ve
Y1
Q1
Y2
-Ve -Ve -Ve -Ve
Q1
+Ve +Ve
-Ve
K1
K1
K1
Y1
-Ve
Q1
Fuse
status
Indication
Circuit
Closing Circuit Housing
Earthing
Opening
Circuit
Auxiliary Contact Circuits
Electrical operation wiring diagram of W-SLC-400 withdrawable vacuum contactor-fuse combination units
64 Pin Secondary Disconnect
K1: Closing / Holding relay
PC: Operations counter
Q1: Auxiliary contact (switching when the contactor closes or trips)
SC: Closing button
SO: Opening button
S1: Auxiliary contact (switching when fuse is blown or not tted)*
S8: Auxiliary contact (switching when the trolley is on Test Position)
S9: Auxiliary contact (switching when the trolley is on Connected Position)
Ve: Control supply
V1: Bridge rectier (not included for DC applications)
Y1: Closing coil
* When MV fuse is replaced by a link S1 only switches
when Open push button is pressed.
9
Mechanical latching option
Wiring Diagram
Note: The drawing is shown with the Contactor
Truck in the withdrawn Test Position,
de-energised, with fuses tted and healthy.
K1: Closing relay
K2: Trip relay
PC: Operations counter
Q1: Auxiliary contact (switching when the contactor closes or trips)
SC: Closing button
SO: Opening button
S1: Auxiliary contact (switching when the fuse is blown or not tted)*
S8: Auxiliary contact (switching when the trolley is on Test Position)
S9: Auxiliary contact (switching when the trolley is on Connected Position)
Ve: Control supply
V1: Bridge rectier (not included for DC applications)
V2: Bridge rectier
Y1: Closing coil
Y2: Trip coil
* When MV fuse is replaced by a link S1 only switches
when Open push button is pressed.
+Ve +Ve +Ve
+Ve +Ve
Y1
Q1
Y2
-Ve -Ve -Ve -Ve
Q1
+Ve +Ve +Ve
+Ve +Ve
Y1
Q1
Y2
-Ve -Ve -Ve -Ve
Q1
Fuse
status
Indication
Circuit
Closing Circuit Housing
Earthing
Opening Circuit Auxiliary Contact Circuits
Mechanical latching wiring diagram of W-SLC-400 withdrawable vacuum contactor-fuse combination units
64 Pin Secondary Disconnect
Selection and ordering information
Type W-SLC, 400 A, vacuum contactor ratings
Rated
utilization
voltage
Interrupting rating (kA) Application table Transformer
(kVA)
Capacitor
(A)
*
Maximum
insulation
voltage (V)
Unfused Fused Induction
motor (kW)
Synchronous motor (kW)
(0.8 PF) (1.0 PF)
2200 - 2500
3000 - 3600
3800 - 4800
6000 - 6900
8.5
8.5
8.5
8.5
50
50
50
50
1300
1675
2250
3350
1300
1675
2250
3350
1500
1850
2600
4100
1500
2000
2500
4000
295 7200
*
Ratings not applicable for back-to-back switching. Please contact Customer Service for back-to-back switching applications.
Rated current .......................................................400 A enclosed
Max fuse rating .................................................................. 355 A
Fused combination ............................................................. 200 A
IEC make-break capability-AC4
Make ................................................................................ 4000 A
Break ................................................................................ 3200 A
Maximum interrupting current
(3 Operations) ................................................................... 8500 A
Short time withstand current
30 Second ........................................................................ 2400 A
1 Second .......................................................................... 6000 A
8.7 ms (0.5 Cycle) ......................................................63 kA peak
Fuse protected (based on fuse cut-off) .............................. 50 kA
Normal service altitude .......................................... 1000 meters
Mechanical life ................................................................ 1 million
Electrical life
AC3 & AC4 ....................................................300,000 operations
Impulse withstand ..............................................................60 kV
Dielectric strength ...................................... 20 kV rms (1 minute)
Closing time
(Energization to contact touch) .................................... < 120 ms
Opening times (eld selectable) ......................... < 50 330 ms
Arcing time .............................................................12 ms or less
Control voltages
ac/Hz ..................... 110 / 50, 120 / 60, 220 / 50, 240 / 60 Vac/Hz
dc ........................................................................... 110 / 220 Vdc
Pickup voltage ..........................................80% rated coil voltage
Dropout voltage .......................................60% rated coil voltage
Control circuit burden
Closing 100 125 V ........................................................... 1 kVA
200 240 V ........................................................ 1.8 kVA
Holding 100 125 V ........................................................... 40 VA
200 240 V ........................................................... 50 VA
Auxiliary contact rating
Voltage (maximum) ............................................................ 600 V
Continuous current ............................................................... 10 A
Making capacity (ac) ................................................... 7200 VA
(dc) ..................................................... 125 VA
Breaking capacity (ac) ..................................................... 720 VA
(dc) ..................................................... 125 VA
Latch (when specied)
Mechanical life ............................................. 250,000 Operations
Trip voltage (dc) ......................................................... 24 V
(dc) ....................................................... 125 V
(ac) .............................................. 110 / 120 V
Minimum trip voltage .................................... 80% Rated Coil V
Trip burden ....................................................................... 400 VA
Trip time .............................................................................30 ms
Weight (without fuses) .......................................................96 kg
Specications
Order instruction
W-SLC 1 SLC014S 5 Y - 66 5
IEC draw-out contactor IEC SL
contactor
7.2 kV, 400 A
1 = with fuses
0 = fuses replaced
by conductors
Note: fuses are
supplied by user
Contactors auxiliary contact
66 = 6 NO, 6 NC
Coil drop-out time
5 = 30 ms
6 = 50 ms
7 = 130 ms
8 = 250 ms
9 = 330 ms
Coil voltage
A = 120 Vac/60 Hz
B = 240 Vac/60 Hz
U = 110 Vac/50 Hz
W = 220 Vac/50 Hz
X = 110 Vdc
Y= 220 Vdc
Mechanical latch
(Coil voltage)
0 = None
4 = 110/50, 120/60 Hz
5 = 220/50, 240/60 Hz
1874 1886 1911 1998 1893 1990 1962 1999 1983 1908 1906 1899 1963
The power of fusion.
Theres a certain energy at Eaton. Its the power of uniting some
of the worlds most respected names to build a brand you can
trust to meet every power management need. The energy created
supports our commitment to powering business worldwide.
From power distribution to power quality and control, Eaton allows
you to proactively manage your complete power system by
providing electrical solutions that make your applications safer,
more reliable, and highly efcient. Visit www.eaton.com/electrical.
All of the above are trademarks of Eaton Corporation or its affiliates. Eaton has a license
to use the Westinghouse brand name in Asia Pacific. 2009 Eaton Corporation.
Eatons electrical business is a global leader with expertise
in power distribution and circuit protection; backup power
protection; control and automation; lighting and security;
structural solutions and wiring devices; solutions for harsh
and hazardous environments; and engineering services.
Eaton is positioned through its global solutions to answer
todays most critical electrical power management challenges.
Eaton is a diversied power management company providing
energy-efcient solutions that help our customers effectively
manage electrical, hydraulic and mechanical power. The
company is a global technology leader in electrical products,
systems and services for power quality, distribution and
control, power transmission, lighting and wiring products;
hydraulics components, systems and services for industrial
and mobile equipment; aerospace fuel, hydraulics and
pneumatic systems for commercial and military use; and
truck and automotive drivetrain and powertrain systems
for performance, fuel economy and safety. Eaton acquired
Cooper Industries plc in 2012. Eaton has approximately
100,000 employees and sells products to customers in more
than 150 countries. For more information, visit www.eaton.eu.
2012 Eaton Corporation
All rights reserved
BR022002EN / January 2013
Europe, Middle East and Africa
Eaton Industries (Netherlands) B.V.
P.O. Box 23
7550 AA Hengelo
The Netherlands
Tel.: +31 74 246 4012
Fax: +31 74 246 4601
SecretariaatCSsystems@eaton.com
www.eaton.eu
Asia Pacic
Eaton Electrical Sector Asia Pacic
Headquarters
No.3 Lane 280 Linhong Road
Changning District
Shanghai 200335, P.R.China
Tel.: +86 21 5200 0099
Fax: +86 21 5200 0200
www.eatonelectrical.com.cn
South America
Eaton Ltda.
Av. Pierre Simon de Laplace, 751
Cond. Techno Park Via Anhanguera,
Km 104,5
Campinas - SP - 13069-320 - Brasil
Tel.: +55 19 2117 0000
eatonelectricalbrasil@eaton.com
www.eaton.com.br
North America
Eaton Corporation
Electrical Sector
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN-CARE (877-386-2273)
www.eaton.com
The information provided in this document
reects the general characteristics of the
referenced products at the time of issue and
may not reect their future characteristics.
Eaton Corporation reserves the right to
modify the contents of this document
and the characteristics of the referenced
products without prior notication. Eaton
Corporation does not assume liability for
potential errors or omission of information
in this document.