You are on page 1of 1

Gas Generator Lube System Interfaces

The maximum allowable loads on the lube system connections are listed in the Table below.
The Purchaser should not install any filters or unnecessary flow impediments in the lube supply line
from the oil tank to the engine lube pump inlet. If a manual shutoff valve must be installed in the lube
supply line for maintenance or other reasons, the valve should be equipped with a flag and padlocked
position guard so that a deliberate, planned act is required to close it.
Gas Generator Lube System Connection Loads.
Connection Shear, lbf Axial, lbf Bending, in-lb
Lube Pump
Inlet Discharge
Scavenge
70
25
60
150
50
160
530
110
420
Lube Supply Inlet Port Pressure Tap
70
50
70
50
210
50
Lube Scavenge Pressure Tap 25 50 50