An engine start takes place when the after-running of the engine control unit is finished (about 20 minutes after
switching off the ignition).
Background: Background: Background: Background: The pressure in the gas tank drops in relation to the falling outside temperature. Below an outside
temperatures of 5C the evaporator therefore does not have enough gas.
Production change Production change Production change Production change
No change
Measure Measure Measure Measure
Measure the gas rail temperature via the rail pressure sensor GX21 (Euro 5).
Technical product information Technical product information Technical product information Technical product information Transaction No.: 2032905/1 2032905/1 2032905/1 2032905/1
Service info: LPG operation at low temperatures not possible (Euro 5) Release date:07-Feb-2013
At low outside temperatures the LPG operation is not automatically switched on.
At low outside temperatures the LPG operation cannot be manually switched on.
The customer statement can reproduced. At low outside temperatures the gas operation is intermittently not
possible.
The LPG system uses an evaporator to reduce the pressure and to convert liquid gas.
Depending on the LPG quality the pressure in the gas tank drops at low outside temperatures to as low as 0
bar. With this pressure the evaporator does not have sufficient gas. This leads to problems of the engine in
gas operation.
With a measured coolant temperature coolant temperature coolant temperature coolant temperature at the 1st engine start of under under under under - -- -15C 15C 15C 15C (Euro 5) or a gas rail gas rail gas rail gas rail
temperature temperature temperature temperature of under 5C under 5C under 5C under 5C (Euro 5) the engine control unit prevents a switch the engine control unit prevents a switch the engine control unit prevents a switch the engine control unit prevents a switch to the gas operation.
The LPG operation is only possible again, if the gas rail temperature stays for a longer period over 5C.
On the Euro 5 select in the engine control unit (address code 01) engine control unit (address code 01) engine control unit (address code 01) engine control unit (address code 01) in self self self self- -- -diagnosis diagnosis diagnosis diagnosis the measured value block measured value block measured value block measured value block
187 187 187 187.
The gas rail temperature is shown in field 4 field 4 field 4 field 4.
Criteria for the switch to the gas operation:
If the above temperatures are shown, the system works correctly. Explain the background to the customer.
Outside temperature > -15C
Coolant temperature > 5C
Engine speed > 1200 rpm
Gas rail temperature > 5C