Using WRC 107/297 in Caesar II

Published by Dave Wolfe in Caesar II on July 6th, 2011


Lately, Ive been trying to track down an error that occurs when trying to run the WRC 107/297
module. Periodically, while running the WRC 107/297 module in Caesar II, the analysis tab will be
blank, and you are unable to proceed with analysis.

We have a temporary workaround in place while we try to troubleshoot the root of the problem.
1. Close Caesar II.
2. Open your registry editor (Start->Run->regedit or Start > and enter regedit in search all
programs and files).
3. Navigate to HKEY_CURRENT_USER\Software\Intergraph CAS\CAESAR II\ 5.30\RunWRC
4. Delete the RunWRC key

When you run Caesar II next and open the WRC module, the
settings will be created all over again, and you should be
able to proceed with analysis.