APPLICATION NOTE ON
BASE PROCESSOR
TERMINAL COMMANDS
System
Practices

Section No. 400-658-0920
Draft 03, June 2005
C-DOT DSS MAX
APPLICATION NOTE ON
BASE PROCESSOR
TERMINAL COMMANDS

2005, C-DOT
Printed in India








C-DOT DSS MAX
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS
DRAFT 03
JUNE 2005
ASADHA 2062
SERIES 600 : SOFTWARE
CSP SECTION NO. 400-658-0920
THIS CDOT SYSTEM PRACTICE REFERS TO THE CDOT DIGITAL SWITCHING SYSTEM
MAIN AUTOMATIC EXCHANGE (ABBREVIATED AS CDOT DSS MAX IN THE REST OF THIS
PUBLICATION).

THE INFORMATION IN THIS SYSTEM PRACTICE IS FOR INFORMATION PURPOSES AND IS
SUBJECT TO CHANGE WITHOUT NOTICE.

A COMMENT FORM HAS BEEN INCLUDED AT THE END OF THIS PUBLICATION FOR
READER'S COMMENTS. IF THE FORM HAS BEEN USED, COMMENTS MAY BE
ADDRESSED TO THE DIRECTOR (C&S), CENTRE FOR DEVELOPMENT OF TELEMATICS,
C-DOT CAMPUS, MEHRAULI, NEWDELHI - 110 030

2005 BY CDOT, NEW DELHI.
Table of Contents
Chapter 1. Introduction ..............................................................................................................................5
Chapter 2. BP Cable Details.......................................................................................................................9
Chapter 3. Base Module............................................................................................................................14
Chapter 4. Remote Base Module Monitoring Through BP Terminal ....................................................29
Chapter 5. Central Module & Administrative Module ...........................................................................34
Chapter 6. Signaling Unit Module (CCS7 Module).................................................................................45
Chapter 7. V5.X Unit.................................................................................................................................51
Chapter 8. Input Output Module (IOP) ...................................................................................................56
Chapter 9. Health Log & Field Debugging Tool......................................................................................60
Annexure I Symbols and Addresses for Various Function ......................................................................66

H:\HOME\MAX\WORD\MXAPBPTCM.DOC June 21, 2005


APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 5
Chapter 1.
Introduction
1.1. GENERAL
During Installation and maintenance of C-DOT SBM/MAX-L/MAX-XL, some times,
it is necessary to use a VT100 terminal connected directly to the processor in the
module to give commands directly to processor in the module. Terminal can be
connected to processor in BM/RBM/SUM/CM/AM using a RS232 cable. From this
terminal, commands can be issued to perform following tasks.
To view the switch unit status in the module
To modify the switch unit status in the module
To initialize the module, when module does not respond to commands from
crp terminal connected to IOP.
To increase SRF counter value.
1.2. SRF COUNTER OVERFLOW PROBLEM
Due to problem in Hardware, data inconsistency, call failures in trunk groups etc.,
system generates recoveries and this can be seen on BP terminal connected to the
respective module. Whenever recoveries exceed default value of 0064 (Hex), system
initializes on its own, going for stable clear. Before problem is identified and
recoveries are stopped, counter value can be increased to FFFF (Hex) to avoid
frequent initialisation of system to stable clear level.
1.3. For Accessing Processor in any module the following things have to be done.
RS232 cable should be prepared as given in the Chapter 2 of this document
for BM-L/BM-XL/SUM.
RS232 cable meant for BM-L (with CPUS04/S05 processor card can be used
in BM-L, CM-L, AM in MAX-L.
RS232 cable meant for BM-XL (with BPC processor card) can be used in BM-
XL, CM-XL & AM in MAX-XL.
Connect the VT100 terminal (VDU) to required module
(BM/RBM/SUM/CM/AM) using RS232 cable. Details of connectors used for
Chapter 1.
6 C-DOT DSS MAX
terminating RS232 cable in each module is given in respective chapters of
this document.
Set the baud rate of terminal to 4800/9600 bps depending on processor in the
module as given below :
CPU S04 - 4800 bps
CPU S05 - 4800 bps
BPC/HPC - 9600 bps
Switch unit identity in HEX for all units is given in Table 1.1
Follow the commands and examples as given for each module in different
chapters.
INTRODUCTION
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 7
1.4. SWITCH UNIT IDS
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 BP1-0 BP1-1 BP2-0 BP2-1 BP3-0 BP3-1 BP4-0 BP4-1 BP5-0 BP5-1 BP6-0 BP6-1 BP7-0 BP7-1 BP8-0 BP8-1
1 BP9-0 BP9-1 BP10-0 BP10-1 BP11-0 BP11-1 BP12-0 BP12-1 BP13-0 BP13-1 BP14-0 BP14-1 BP15-0 BP15-1 BP16-0 BP16-1
2 BP17-0 BP17-1 BP18-0 BP18-1 BP19-0 BP19-1 BP20-0 BP20-1 BP21-0 BP21-1 BP22-0 BP22-1 BP23-0 BP23-1 BP24-0 BP24-1
3 BP25-0 BP25-1 BP26-0 BP26-1 BP27-0 BP27-1 BP28-0 BP28-1 BP29-0 BP29-1 BP30-0 BP30-1 BP31-0 BP31-1 BP32-0 BP32-1
4 SWC1-0 SWC1-1 SWC2-0 SWC2-1 SWC3-0 SWC3-1 SWC4-0 SWC4-1 SWC5-0 SWC5-1 SWC6-0 SWC6-1 SWC7-0 SWC7-1 SWC8-0 SWC8-1
5 AP-0 AP-1 ADC IOP-0 IOP-1 SU7-0 SU7-1
6 SS-0 SS-1 SSC-0 SSC-1 CMS1 CMS2 CMS3 CMS4 IFC1 IFC2 IFC3 IFC4 IFC5 IFC6
7 IFC7 IFC8 IFC9 IFC10 IFC11 IFC12 IFC13 IFC14 IFC15 IFC16 IFC17 IFC18 IFC19 IFC20 IFC21 IFC22
8 IFC23 IFC24 IFC25 IFC26 IFC27 IFC28 IFC29 IFC30 IFC31 IFC32 CLK-0 CLK-1 SSBID-0 SSBID-I
9 MU-0 MU-1 BMS-0 BMS-1 SCIC-0 SCIC-1 TSC-0 TSC-1
A T101-0 T101-1 T102-0 T102-1 T103-0 T103-1 T104-0 T104-1 T105-0 T105-1 T106-0 T106-1 T107-0 T107-1 T108-0 T108-1
B T109-0 T109-1 T110-0 T110-1 T111-0 T111-1 T112-0 T112-1 T113-0 T113-1 T114-0 T114-1 T115-0 T115-1 T116-0 T116-1
C ICCI-0 ICC1-1 ICC2-0 ICC2-1 ICC3-0 ICC3-1 ICC4-0 ICC4-1 VP-0 VP-1 VMU-0 VMU-1
D TTC ANNC
E SWC9-0 SWC9-1 SWC10-
0
SWC10-
1
SWC11-
0
SWC11-
1
SWC12-
0
SWC12-
1
SWC13-
0
SWC13-
1
SWC14-
0
SWC14-
1
SWC15-
0
SWC15-
1
SWC16-
0
SWC16-
1

F MFC1 MFC2 MFC3 MFC4 TOGC-0 TOGC-1
Table 1.1
Note:
1. All CRP Ids used
2. Usage unit id (UID) = Row No. followed by Column No.
3. Example: Say for IFC17 Row No = 7, Column A Hence UID for IFC17 is 7A.
4. BP1-0, BP1-1 represent BP-0, BP-1 for BM1, BP2-0, BP2-1 represent BP-0,BP1 for BM-2.. So on.
Ex : Unit ids for BP_0 & BP_1 of BM 32 are 3E, 3F respectively. Unit ids for BP_0 & BP1 of BM 10 are 12,13
Chapter 1.
8 C-DOT DSS MAX
STATUS OF UNITS
Numbers in HEX representing the status of switch units are given below with
status of switch units.


HEX
ID
STATUS HEX
ID
STATUS
02 INS-ACT (Inservice Active) 04 INS-SBY (Inservice Standby)
08 INS-FRC (Inservice forced) 90 OOS-INI (Out of service
Initialization)
91 OOS-EXT (Out of service
external)
93 OOS-EXT (Out of service
external)
94 OOS-TST (Out of service test) 96 OOS-SUS (Out of service
suspect)
98 OOS-SYS (Out of service
system)
9A OOS-OPR (Out of service
operator)
! CAUTION Working on 'BP' Terminal should be done very carefully
particularly in a working exchange. A careless handling
may cause the module to go for initialization. Some times
corruption of data may also occur. While handling BP
terminal one should be utmost sure about the commands
to be given.

APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 9
Chapter 2.
BP Cable Details
This chapter gives the details of a pictorial view of various BP cables and its
drawing reference ie., C-DOT Assy. No. with the help of which all these cable can be
prepared easily at the site.
These cables are generally supplied with the equipments with the following
description.
Part Code
For MAX-XL
AP/BP Terminal Cable Assy.
(8 pair telephone cable 0.4 mm, 25 Mtrs length)
ACB-MAXXBPTX-000
For SUM
BP Terminal Cable Assy. for SUM
(8 pair telephone cable 0.4 mm, 25 Mtrs length)
ACB-MAXXSUTX-000
For MAX-L
AP/BP Terminal Cable Assy. for
(8 pair telephone cable 0.4 mm, 25 Mtrs length)
ACB-RSUVTEZX-00

Chapter 2.
10 C-DOT DSS MAX
2
5

P
I
N

D
-
T
Y
P
E
W
I
R
E
W
R
A
P

(
F
E
M
A
L
E
)
2
5

M
T
s

(
M
A
X
)
8

P
A
I
R

T
E
L
E
P
H
O
N
E
C
A
B
L
E

(
0
.
4
m
m
)
D
E
S
T
I
N
A
T
I
O
N
B
P

/
B
P
1
S
O
U
R
C
E
V
D
U
M
C
C
-
B
P
C
S
Z
0
1
2
-
4
0
1
M
C
C
-
B
P
C
S
Z
0
1
1
-
4
0
1
M
C
C
-
B
P
C
S
Z
0
2
2
-
4
0
1
M
C
C
-
D
C
F
M
Z
0
0
2
-
3
0
1
T
E
Z
1
X
Z
E
T
B
P

T
E
R
M
I
N
A
L

C
A
B
L
E

F
O
R

B
M
-
L
/
C
M
-
L
F
I
G
.

2
.
1
2
Z
E
T
C
O
N
N
E
C
T
O
R
B
C
O
N
N
E
C
T
O
R
A
( ( (
(
C
)
S
I
N
G
L
E

M
O
D
U
L
E

C
O
V
E
R
(
b
)
C
O
N
T
A
C
T

B
L
O
C
K
7
x
2

P
I
E
R
C
I
N
G

B
L
O
C
K
(
a
)
7
x
2

I
D
C

C
R
I
M
P

C
O
N
N
E
C
T
O
R
C
O
N
S
I
S
T
I
N
G

O
F
1
M L
1
L
2
1
M
S
.

N
o
.
C
D
O
T

A
S
S
Y

N
o
.
F
R
O
M
T
O
C
A
B
L
E
M
A
R
K
E
R
1
A
C
B
-
R
S
U
V
T
E
Z
X
-
0
0
V
T
-
2
2
0

T
E
R
M
I
N
A
L
B
P
T
E
Z
1
V
T
-
2
2
0

T
E
R
M
I
N
A
L
B
P
T
E
Z
2
A
S
S
E
M
B
L
Y

I
N
S
T
R
U
C
T
I
O
N
S
2
5

P
I
N

D

T
Y
P
E
C
O
N
N
E
C
T
O
R
A B
P
I
N

S
I
G
N
A
L
C
A
B
L
E

P
A
I
R
7
x
2
C
O
N
N
E
C
T
O
R

P
A
I
R
2
T
x

(
V
D
U
)
W
H

O
F

B
L
-
W
H
1
c
1
a
B
L

O
F

B
L
-
W
H
R
x

(
V
D
U
)
3 7
G
N
D

(
V
D
U
)
O
R
,

W
H

O
F

O
R
-
W
H
2
a
,

2
c
6
a
,

6
c
B
N
,

W
H

O
F

B
N
-
W
H
G
N

O
F

G
N
-
W
H
5
a
5
c
W
H

O
F

G
N
-
W
H
C
O
N
N
E
C
T
O
R
7 2 3
G
N
D

(
V
D
U
)
R
x

(
V
D
U
)
T
x

(
V
D
U
)
N
O
T
E
:

U
S
E

S
I
L
I
C
O
N

R
U
B
B
E
R

S
L
E
E
V

O
N
L
E
N
G
T
H
S

L
1
,

L
2
\
D
E
S
I
G
N
\
D
S
S
M
A
X
\
M
A
X
-
X
L
\
B
P
T
R
M
N
L
\
B
P
-
B
T
C

BP CABLE DETAILS
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 11
\
D
E
S
I
G
N
\
D
S
S
M
A
X
\
M
A
X
-
X
L
\
B
P
T
R
M
N
L
\
R
S
X
L
I
M
A
S
O
V
E
R

L
E
N
G
T
H

L
1
,

L
2

A
N
D
P
U
T

6
.
0
m
m

B
L
A
C
K

S
I
L
I
C
O
N

R
U
B
B
E
R


S
L
E
E
V
E
(
A
)
A
S
S
E
M
B
L
Y

I
N
S
T
R
U
C
T
I
O
N
M
C
C
-
D
C
F
M
Z
0
0
2
-
3
0
1
W
I
R
E
W
R
A
P

(
F
E
M
A
L
E
)
2
5

P
I
N

D
-
T
Y
P
E
C
O
N
N
E
C
T
O
R
C
O
N
N
E
C
T
O
R
S
O
U
R
C
E A
V
D
U
B
2
5
M

(
M
A
X
)
P
B
1
T
1
M
B
P
T
2
C
A
B
L
E

(
0
.
4
m
m
)
8

P
A
I
R

T
E
L
E
P
H
O
N
E
V
T
-
2
2
0

T
E
R
M
I
N
A
L
V
T
-
2
2
0

T
E
R
M
I
N
A
L
A
C
B
-
M
A
X
X
B
P
T
X
-
0
0
0
C
D
O
T

A
S
S
Y

N
o
.
S
.

N
o
.
1
F
R
O
M
T
O
B
P

B
P
1
C
A
B
L
E
M
A
R
K
E
R
B
P
T
1
B
P
T
2
C
O
N
N
E
C
T
O
R
D

T
Y
P
E
(
B
)
A
P
I
N

N
o
.
3 2
B
7 3 7 2
(
C
)
B
P

D
E
S
T
I
N
A
T
I
O
N
1
P
B
T
2
P
B
T
0
.
2
5
M
3
C
O
N
N
E
C
T
O
R
1 2 4
A
3 1 2
C
O
N
N
E
C
T
O
R
4
B
P
I
N

2
0

T
O

P
I
N

6

A
N
D

P
I
N

8
P
I
N

4

T
O

P
I
N

5
O
N

E
A
C
H

D

T
Y
P
E

C
O
N
N
E
C
T
O
R

S
H
O
R
T

A
S

F
O
L
L
O
W
S
.
C
O
N
S
I
S
T
I
N
G

O
F
7
x
2

I
D
C

C
R
I
M
P

C
O
N
N
E
C
T
O
R
S
I
N
G
L
E

M
O
D
U
L
E

C
O
V
E
R
7
x
2

P
I
E
R
C
I
N
G

B
L
O
C
K
C
O
N
T
A
C
T

B
L
O
C
K
(
a
)
(
C
)
(
b
)
D
E
S
T
I
N
A
T
I
O
N
B
P
1
D
T
R

T
O

D
R
S

D
C
D
R
T
S

T
O

C
T
S
(
1
)
(
2
)
R

X

D

(
V
D
U
)
T

X

D

(
V
D
U
)
S
I
G
N
A
L
S
O
U
R
C
E
B
L
W
H
P
A
I
R
B
L
-
W
H
B
L
-
W
H
M
C
C
-
B
P
C
S
Z
0
2
2
-
4
0
1
)
M
C
C
-
B
P
C
S
Z
0
1
1
-
4
0
1
)
M
C
C
-
B
P
C
S
Z
0
1
2
-
4
0
1
)
( ( (
P
I
N

N
o
.
(
7
x
2

M
O
D
U
L
E
)
D
E
S
T
I
N
A
T
I
O
N
A
4
c
5
a
T

X

D

(
V
D
U
)
R

X

D

(
V
D
U
)
D
I
G
I
T
A
L

G
N
D
D
I
G
I
T
A
L

G
N
D
W
H
O
R
,
W
H
G
R
B
L
-
R
D
G
R
-
W
H
O
R
-
W
H
G
R
-
W
H
B
L
-
R
D
T
I
E

W
I
T
H

C
A
B
L
E
B
5
c
4
c
5
c
5
a
F
I
G
.

2
.
2
B
P

T
E
R
M
I
N
A
L

C
A
B
L
E

F
O
R

B
M
-
X
L
/
C
M
-
X
L

Chapter 2.
12 C-DOT DSS MAX
2
5

P
I
N

D
-
T
Y
P
E
W
I
R
E
W
R
A
P

(
F
E
M
A
L
E
)
2
5

M
T
s

(
M
A
X
)
8

P
A
I
R

T
E
L
E
P
H
O
N
E
C
A
B
L
E

(
0
.
4
m
m
)
S
O
U
R
C
E
S
U
7
-
0
/
S
U
7
-
1
D
E
S
T
I
N
A
T
I
I
O
N
V
D
U
M
C
C
-
B
P
C
S
Z
0
1
2
-
4
0
1
M
C
C
-
B
P
C
S
Z
0
1
1
-
4
0
1
M
C
C
-
B
P
C
S
Z
0
2
2
-
4
0
1
M
C
C
-
D
H
X
X
X
T
2
5
-
1
0
0
S
U
M
1
X
T
U
S
B
P

T
E
R
M
I
N
A
L

C
A
B
L
E

F
O
R

S
U
M
F
I
G
.

2
.
3
2
M
U
S
C
O
N
N
E
C
T
O
R
B
C
O
N
N
E
C
T
O
R
A
( ( (
(
C
)
S
I
N
G
L
E

M
O
D
U
L
E

C
O
V
E
R
(
b
)
C
O
N
T
A
C
T

B
L
O
C
K
7
x
2

P
I
E
R
C
I
N
G

B
L
O
C
K
(
a
)
7
x
2

I
D
C

C
R
I
M
P

C
O
N
N
E
C
T
O
R
C
O
N
S
I
S
T
I
N
G

O
F
1
M L
1
L
2
1
M
S
.

N
o
.
C
D
O
T

A
S
S
Y

N
o
.
F
R
O
M
T
O
C
A
B
L
E
M
A
R
K
E
R
1
A
C
B
-
M
A
X
X
S
U
T
X
-
0
0
0
V
T
-
2
2
0

T
E
R
M
I
N
A
L
S
U
7
-
0
S
U
M
1
V
T
-
2
2
0

T
E
R
M
I
N
A
L
S
U
7
-
1
S
U
M
2
A
S
S
E
M
B
L
Y

I
N
S
T
R
U
C
T
I
O
N
(
A
)
O
N

E
A
C
H

D

T
Y
P
E

C
O
N
N
E
C
T
O
R

S
H
O
R
T

A
S

F
O
L
L
O
W
S
.
(
1
)
R
T
S

T
O

C
T
S
P
I
N

4

T
O

P
I
N

5
(
2
)
D
T
R

T
O

D
R
S

D
C
D
P
I
N

2
0

T
O

P
I
N

6

A
N
D

P
I
N

8
D

T
Y
P
E
C
O
N
N
E
-
A B
P
I
N

N
o
.
S
I
G
N
A
L
D
E
S
T
I
N
A
T
I
O
N
P
A
I
R
S
O
U
R
C
E
(
7
x
2

M
O
D
U
L
E
)
3
T

X

D

(
V
D
U
)
W
H
B
L
-
W
H
1
a
(
B
)
1
C
B
L
-
W
H
B
L
R

X

D

(
V
D
U
)
2 7
D
I
G
I
T
A
L

G
N
D
O
R
,
W
H
O
R
-
W
H
2
a
,

2
c
4
a
,

4
c
B
L
-
R
D
B
L
-
R
D
D
I
G
I
T
A
L

G
N
D
7 2
R

X

D

(
V
D
U
)
G
R
G
R
-
W
H
3
c
3
a
G
R
-
W
H
W
H
T

X

D

(
V
D
U
)
3
(
C
)
P
U
T

6
.
0
m
m

B
L
A
C
K

S
I
L
I
C
O
N

R
U
B
B
E
R


S
L
E
E
V
E
O
V
E
R

L
E
N
G
T
H

L
1
,

L
2

A
N
D
T
I
E

W
I
T
H

C
A
B
L
E
M
C
C
-
D
C
F
M
Z
0
0
2
-
3
0
1
C
T
O
R
\
D
E
S
I
G
N
\
D
S
S
M
A
X
\
M
A
X
-
X
L
\
B
P
T
R
M
N
L
\
M
X
I
-
A
S

BP CABLE DETAILS
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 13
In all the configurations the source is the Base Processor frame with different
connector location. Following table gives details of the exact points of connection.

For BM-L/CM-L/AM-L
Rack BM (BP) CM (SSC) CM (AP)
Frame 5 3 4
Slot 2 2 2
Connector B A A
Tab No. 1 1 1

For BM-XL/CM-XL/AM-XL
Rack BM (BP) CM (SSC) CM (AP)
Copy 0 Copy 1 Copy 0 Copy 1 Copy 0 Copy 1
Frame 5 5 5 5 6 6
Connector J7 J24 J25 J52 J20 J36
Tab No. 4 4 1 1 1 1

For SUM/VU
Connection Position : Slot 5 / connector A / Tab 2

14 C-DOT DSS MAX
Chapter 3.
Base Module
3.1. BASE MODULE
3.1.1. Accessing BP in Base Module
BP of BM can be accessed to view/modify switch unit status, modifying SRF
counter values whenever BM generates recovery messages due to fault in
hardware/software/data problems. BP of BM can be accessed by directly
connected terminal to BPU. However, it is also possible to access BP of BM
from CRP terminal connected to IOP provided module is active and this
procedure also has been described. Connect the BP cable form terminal to
BPU frame as given below to access BP of Base Module.
For BM-L (CPUS04/S05)
Source : RS232 port of VDU
Destination : Frame 5 / slot 1 / B connector / Tab 1
Note : Set baud rate of terminal to 4800 bps for CPU S04
and CPU S05
For BM-XL (BPC)
Source : RS232 port of VDU
Destination : Frame 5 / Slot 11 / B connector / Tab 4 for Copy 0
Frame 5 / Slot 20 / B connector / Tab 4 for Copy 1
Note : Set baud rate of terminal to 9600 bps for BPC/HPC
cards in BPU.
3.1.2. Procedure to View Switch Status on BP Terminal
Switch unit status in BM can be seen from BP terminal, connected directly to
BPU respective of BM or from any IOP terminal.
In the procedure given below, we have used symbol mbc_bm_unit to view
switch unit status map. Alternatively, we can use address also to define and
view the unit status map. Address for required symbol can be derived from
BASE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 15
BP terminal or IOP terminal. However, note that symbols remain same
across different software releases, whereas addresses may be different in
different software releases. While using address, derive address from BP or
IOP terminal as described below.
Deriving address for required symbol from BP terminal
(BM/RBM/AM/CM/SUM/VU)
MDEBXX> sy mbc_bm_unit (XX is bp id of copy 0 processor of that module)
mbc_bm_unit : 0 x cc3202
(Address for symbol mbc_bm_unit is cc3202)
mdebxx> ex
cdos> ex
Note : Procedure to derive address for symbol from IOP terminal is described
in chapter 8 (Input Output module).
For eg: For symbol mbc_bm_unit address is cc3202 in S/W release 2_2_1_6
for MBM.
PROCEDURE TO VI EW UNI T STATUS
Define the address of unit status map (mbc_bm_unit as us) as follows :
Press ctrl-D, you should get CDOS prompt. If terminal continuously prints
62, then change 25 pin connector in terminal end of BP cable for other copy of
CPU. After changing connector, press control D again to get CDOS prompt.
CDOS XX>m
Note : Here XX indicates BP id in Hex corresponding to that BM. BP ids are
given in Table 1.1.
### WELCOME TO DD, MBEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEBXX> def us md @mbc_bm_unit l+100
Logical symbol US defined
Alternatively use address to view unit status as given below :
MDEBXX> def us md cc3202 l + 100
Logical symbol US defined.
MDEBXX>prn e
Chapter 3.
16 C-DOT DSS MAX
Note :
Now type US on MDEB prompt to see unit status and type def on MDEB
prompt to see the defined symbols. XX is BP identity in BM in Hexadecimal.
In this example unit status map is shown for BM-10.
TO SEE THE DEFINED SYMBOLS GIVE THE FOLLOWING COMMAND :
MDEB12 > def
To view the unit status map in that BM.
MDEB12> us

00CC3202 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@
00CC3212 C0 C0 04 02 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@..@@@@@@
00CC3222 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@
@
00CC3232
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@
00CC3242
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@
00CC3252
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@
00CC3262
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@.@@@
00CC3272
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@
00CC3282
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@
00CC3292
C0 C0 C0 C0 C0 C0 02 02 04 02 C0 C0 02 04 02 98 @@@@@@
00CC32A2
02 91 02 91 02 91 02 91 02 91 02 91 02 91 02 91
00CC32B2
02 91 02 91 02 91 02 91 02 91 02 91 02 91 02 91
00CC32C2
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@
00CC32D2
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 02 02 C0 @@@@@@@@
00CC32E2
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@
00CC32F2
02 02 02 02 C0 C0 C0 C0 02 04 C0 C0 C0 C0 C0 C0 .@@@@.

Table 3.1
MDEB12>ex
CDOS12>ex
Note :
Unit-id can be derived from table 1.1 and status of units as displayed in unit
status map shown in table 3.1 are given in Table 3.2.
BASE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 17

Unit_id Unit Status Unit_id Unit Status
12 BP-0 (BM-10) Ins-sby
13 BP-1 (BM-10) Ins-act
A0,A2,A4,A6 TI01-0 to TI04-0 Ins-act
96 MU-0 Ins-act
97 MU-1 Ins-act
A1,A3,A5,A7 TI01-1 to TI04-1 Oos-ext
98 BMS-0 Ins-sby
99 BMS-1 Ins-act
A8,AA,AC,AE TI05-0 to TI08-0 Ins_act
9c SCIC-0 Ins-act
9d SCIC-1 Ins-sby
A9,AB,AD,AF TI05-1 to TI08-1 Ins-act
9e TSC-0 Ins-act
9f TSC-1 Oos-sys
B0,B2,B4,B6 TI09-0 to TI12-0 Ins-act
dd TTC Ins-act
de ANNC Ins-act
B1,B3,B5,B7 TI09-1 to TI12-1 Oos-ext
fo MFC1 Ins-act
f1 MFC2 Ins-act
B8,BA,BC,BE TI13-0 to TI16-0 Ins-act
f2 MFC3 Ins-act
f3 MFC4 Ins-act
B9,BB,BD,BF TI13-1 to TI16-1 OoS-ext
f8 TOGC-0 Ins-act
f9 TOGC-1 Ins-sby

Table 3.2
Here we have used symbol US (any other characters can also be used) see the
unit status map stored in memory. On typing us and then return, unit status
map is displayed as given above. First column of the unit status map
contains the address of the locations. The remaining columns contains the
unit status. This map contains status of unit represented by numbers (i.e. 02
Ins-act, 04 Ins-sby etc.) and numbers representing status units is given
in Table 1.1. We can see from the table that, in 2
nd
row after address, 04, 02
exists in 3
rd
, 4
th
locations. This is status of unit ids BP10-0, BP10-1 and thus
this US map indicates status of units of BM10.
Example :
a) To check the status of both copies of BP in unit status map shown in
Table 3.1
In table 3.1, the first column is address and other columns contain
status of switch units. In US map in Table 2.1 we can see that 04,02
exist in 2
nd
row in locations i.e. unit id row x column works out to 12,
Chapter 3.
18 C-DOT DSS MAX
13 for BP-0 & BP-1 respectively. Thus we can see that BP-0 is in ins-
standby status and BP-1 is in ins-act status.
Note :
To calculate BP id use the procedure given below or refer table 1.1
BP-0 UID = [(BM-NO * 2) 2] } Result of the expression in
decimal may be converted to
BP-1 UID = [(BM-NO * 2) 1] } hexadecimal to get Bp id.
Ex : BP-0 ID of BM-6 is 6*2-2=10 =0A (in HEX)
b) To check the status of TSC-1 in unit status map shown in table 2.1
From Table 1.1, we can derive switch unit identity in the Hex for TSC-
1 and it is 9f. From Table 3.1 we can see that location 9f (start
counting rows from 0 and go to 9
th
row, start counting columns from 0
and go to 15
th
column. (i.e. first column is address and should not be
included while counting row/column). We can see that location 9f has
value 98, which indicates that TSC-1 is in oos-sys status. Thus TSC-1
is in oos-sys status.
Similarly, other unit status also can be checked. Note that both
memories (unit identifies 96,97) are active as it should be.
The table below shows the UNIT and its UID in HEX
SWITCH UNIT UID in HEX
BP-0 (BM-NO * 2) 2 (in HEX)
BP-1 (BM-NO * 2) 1 (in HEX)
MU-0 96
MU-1 97
BMS-0 98
BMS-1 99
SCIC-0 9C
SCIC-1 9D
TSC-0 9E
TSC-1 9F
TIC1-0 to TIC8-1 A0 to AF
TIC9-0 to TIC16-1 B0 to BF
MFC1 to MFC4 F0 to F3
TTC DD
ANNC DE
TOGC-0 F8
TOGC-1 F9
Table 3.2
Note : Except BP-0 and BP-1 all other Unit IDs are common for all BMs
BASE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 19
Status of Units :
02 INS-ACT
04 INS-SBY
9A 00S-OPR
91 00S-EXT
98 00S-SYS
96 00S-SUS
C0 UNEQUIPPED
08 INS-FRC
Note : BP cables are same for BM-CPU, AM-CPU and CM-CPU, but it
is different for MAX-L and MAX-XL, Chapter 2, gives details of
BP cables.
3.1.3. Procedure to Modify Switch Unit Status in BM
From BP terminal we can modify status of switch units. Switch unit status
can be modified from ins_sby to oos-opr, oos-sys to oos-opr, oos-opr to ins-sby
etc. Interchange of active and standby units is also possible.
CDOSXX> m
MDEBXX> def m ml ~mcm (Instead of mcm, pmsp can be used. Then
action code 0 or 1 can be used in put or force options)
MDEBXX> m
Buffer size :
Opcode : mswins OR mstreq OR mswich
Subfield : 1
All other parameters except the two given below take default value.
Action code :1 (when pmsp is used only in place of mcm, 0 or 1 i.e put or
force both options can be used.)
* unit ID : UID [Here type unit id in hex.]
MDEBXX> ex
CDOSXX> ex
Chapter 3.
20 C-DOT DSS MAX
Note : Depending on action to be taken i.e. to make a switch unit,
inservice, out of service or interchange of active/or standby, use
required op code as given below :
Opcode = mswins for changing unit status to ins-act/ins-sby
= mstreq for changing unit status to oos-opr
= mswich for interchanging active and standby
units
Note : Do Not modify status of MU-0 and MU-1.
Ex : To modify the TI01-1 Switch unit status to OOS-OPR in BM-1
from BP terminal. From table 1.1 id for T101-1 is derived as A1.
Press control D.
CDOS>m
### WELCOME TO DD, MDEBUG & RETEST ###
.Type HE for MDEB & HE_P for DD help
MDEB 0 > def m ml ~mcm
Logical symbol M redifined/defined.
MDEB 0 > m
Buffer size = ? (24[1], 256 [2], 512[3], 1024[4]) (def = 128)
Struct {
Opcode = mstreq
Char subfield = 1
Char dummy =
Sender_pid =
Mnt_com_hd {
Unsigned short user_id =
Unsigned char session_id
Unsigned char job_id =
} mci_hdr;
unsigned char action_cod = 1 1 represent type of action i.e. force
unsigned char unit_id = a1 Here a1 is switch unit id for TI01-1
} MSTREQ;
% MDEB-I-INFO, Send ret. Val = 0
MDEB 0 > ex
CDOS_0 > ex STACK DUMP
Note : Now view the switch unit status map by typing US on MDEB
prompt. In US map TI01-1 should be in oos-opr status.
BASE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 21
3.2. PROCEDURE TO MODIFY SRF COUNTER VALUE
When BM goes for STB-CLR due to SRF COUNTER OVER-FLOW, modify the SRF
counter size to FFFF, then isolate the problem. This will avoid BMs going for
frequent STB-CLR due to SRF OVER-FLOW. This can be done from the IOP
terminal or through BP terminal.
a) PROCEDURE TO INCREASE SRF COUNTER VALUE FROM IOP
TERMINAL
I0P5C > conp
Conp > m xx (xx is the BM BP ID for which SRF to be modified.)
MDEBxx>sy mrp_m_ro (To get the SRF address say XXXX)
Note: For S/W release 2_2_1_6 add 600 in Hex to address XXXX.
b) PROCEDURE TO INCREASE SRF COUNTER VALUE FROM BP
TERMINAL
Press control D Note :
CDOSxx> m (xx is the BM BP ID for which SRF to be
modified.
MDEBxx> prn e Prn e stands for print enable. This is to be
done to see recovery or general
MDEBxx> ex messages on BP terminal.
CDOS-XX> ex
Example : To modify SRF counter value
For BM-1
Iop5C > conp
CONP > m 0
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 0>sy mrp_m_ro
mrp_m_ro : 0 x 5b1542 add 600 in Hex to get SRF counter
address
i.e. 5b1542+600 5b1b42 .
MDEB 0> exm.w 5b1b42
Type CR to skip, space to modify, minus to go back (max = 9),
Plus to come back (max = 9), dot to exit
005B1B42 0064? ffff
005B1B44 0030 ? . (press dot and return)
MDEB 0> ex
CONP > ex
Chapter 3.
22 C-DOT DSS MAX
3.3. PROCEDURE FOR MODIFYING UNIT STATUS BY EDITING UNIT
STATUS MAP
Unit status can also be modified by directly editing the unit status in the
unit_status address, instead of mailing through ml~mcm. After modifying unit
status give SOFT-START to the BM, BM comes up with modified to us provided
modified unit cards are in good condition, else it goes back to its original status.
Note : This procedure involves down time and should be used with BP-
CABLE connected to any of the BM-CPU.
Press Control D
CDOSxx>m xx (Where xx is the BP-0 id of the required BM).
MDEBxx> hlt sys (HALT-SYS to prevent BMs updating its original status)
MDEBxx>exm.w yyyy (YYYY is unit address)
After updating the unit status type. In the next address so that it comes back to
MDEB>XX>> prompt.
MDEBxx> init s (To give SOFT START).
Example given below shows how to change TIC1-0 to TIC4-0 of BM-27 oos-opr
The address of the unit status to be changed from unit status map. First locate the
line in which the UNIT is available, note down address of that line for example
TI01-0 is in 11
th
line its address is cc32a2.
Press Control D
CDOS 34_0 >m
### WELCOME TO DD, MDEBUG & RETEST ###
.Type HE for MDEB & HELP for DD help
MDEB34 > US
00CC3202 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC3212 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC3222 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC3232
C0 C0 C0 C0 04 02 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@. . @@@@@@@@@@
00CC3242
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC3252
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC3262
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@. @@@@@@@@@@
00CC3272
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC3282
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC3292
C0 C0 C0 C0 C0 C0 02 02 02 04 C0 C0 02 04 02 04 @@@@@@. @@.
BASE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 23
00CC32A2
02 04 02 04 02 04 02 04 04 02 04 02 04 02 04 02 .
00CC32B2
04 02 04 02 04 02 04 02 02 04 02 04 02 04 C0 C0 . . @@
00CC32C2
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC32D2
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 02 02 C0 @@@@@@@@@@@@@. . @
00CC32E2
C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 @@@@@@@@@@@@@@@@
00CC32F2
02 02 02 02 C0 C0 C0 C0 02 04 C0 C0 C0 C0 C0 C0 . @@@@. . @@@@@.
Table 2.5
MDEB34> hlt sys
MDEB34> exm.w cc32A2
Type CR to skip, space to modify, minus to go back (max = 9),
plus to come back (max = 9), dot to exit
00CC32A2 0204? 9A02
00CC32A4 0204? 9A02
00CC32A6 0204? 9A02
00CC32A8 0204? 9A02
00CC32AA 0204? . (enter dot and press return)
MDEB34> init s
Note : When BM comes up after soft start, view the unit status in US map.
3.4. PROCEDURE TO ENABLE DGN PRINT ON BP TERMINAL
This is required to be done when we want to get DGN failure report on BP terminal
while conducting DGN for Switch-Units.
This can be seen only from BP, Terminal connected to the BM whose switch-unit is
being diagnosed.
Connect BP terminal to BM.
Press Control D
CDOSxx>m
MDEBxx>sy mda_print_flag (To get mda_print address)
mda_print_flag : 0xcc6fa4
MDEBxx>exm.w cc6fa4
Exact procedure is given in example below :
Note : Whenever dgn fails, address value will be restored to 0000. To get
reports again, repeat above procedure.
Chapter 3.
24 C-DOT DSS MAX
Ex :
Press control D
CDOS34 > m
MDEB 34>exm.w cc6fa4
Type CR to skip, space to modify, minus to go back (max = 9),
plus to come back (max=9), dot to exit
00CC6FA4 0000? 0101
00CC6FA6 020C? . (enter dot and press return)
MDEB 34> prn e
MDEB 34>ex
CDOS 34_0>ex
Unit tested A1 Here A1 is unit id i.e. TI01-1
Failed to contact TIC
Failed to contact TIC via alternate path.
3.5. PROCEDURE TO CHECK WHICH SWITCH UNIT IS BEING DIAGNOSED
3.5.1. Procedure to Know Whether Switch Unit is being Diagnosed
This can be seen from IOP terminal OR BP terminal.
IOP5X > conp
CONP> m xx (xx is BP) id for required BM)
MDEBxx>msg ~DAP (DAP = Diagnostic Aid Process)
When switch unit is not being diagnosed you will get message as below
OWNER ADDRESS OPCD SENDER MLEN
6C0 NONE
When SWU-UNIT is being diagnosed you will get message as :
OWNER ADDRESS OPCD SENDER MLEN
6C0 62A400 A7 18A10080 E
3.5.2. PROCEDURE TO FIND OUT THE IDENTITY OF SWITCH UNIT
BEING DIAGNOSED
Press control D in BP terminal.
CDOSXX > m
MDEBXX> def dgn exs mda_working _unit
Logical symbol dgn defined
BASE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 25
MDEBXX>dgn
00B4CB38 B0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Note : The line above is in response to typing dgn on MDEB prompt. First
byte contains unit id in Hex which is being diagnosed. In this example,
B0 is first byte and B0 is unit id for T109-0.
3.6. UNIT STATUS OF CONTROLLERS IN ISTU
ITC-0, ITC-1 are functioning as TIC as ISDN frame and have unit ids similar to
TIC ids.
ICC-0 and ICC)1 UID depends on which frame ISDN is equipped.
ICC1-0 ICC1-1 ISDN Equipped in I frame of BM
ICC2-0 ICC2-1 ISDN Equipped in II frame of BM
ICC3-0 ICC3-1 ISDN Equipped in III frame of BM
ICC4-0 ICC4-1 ISDN Equipped in IV frame of BM
UNIT NAME UID (Unit identify) in BP
ICC1-0 & ICC1-1 C0 & C1
ICC2-0 & ICC2-1 C2 & C3
ICC3-0 & ICC3-1 C4 & C5
ICC4-0 & ICC4-1 C6 & C7
Table 2.6
Note : Unit status for ISTU can be modified as described previously for other BM
units. For ITC to come in service corresponding ICC should be
brought inservice first.
3.7. INITIALISATION FROM BP TERMINAL CONNECTED TO MODULE
Command may be issued for initialising the module to which BP terminal is
connected. AM/CM/BM/SUM may be initialised from terminal connected to
respective module.
PROCEDURE TO INITIALISE FROM TERMINAL CONNECTED TO MODULE
Connect BP terminal to module and set the communication speed to 4800/9600 bps
as required. Suppose we want to module to soft start level.
Press control D
CDOS XX > m
MDEB XX > init
Chapter 3.
26 C-DOT DSS MAX
Init options :
Q : Quit
S : Softstart
P : Part init
I : Patch init
C : Code load
Default - stable clear.
Init option > S
Note : Module will go for soft start & come up.
3.8. TYPICAL MESSAGES COMING ON BP TERMINAL
3.8.1. Normal Messages (Do not require any action)
i) Following are the normal messages appearing on a BP terminal :
OSPM>> CPU IDLE_TIME = 284144ms DURING THE PAST 300340
ms [=94%]
TIME IS 30-MAY-2001 22:46:09
ii) Heal !! WOKEUP AT BOUNDAY HOUR
iii) Whenever a MODULE recovers after initialisation, all its switch units
get initialise and if the initialisation is successful, all the working
`TICs get unblocked at the end with following messages :
% OCP>> INIT CONTROL LEVEL : 5
% OCP>> TIC UNBLOCKED = A03580
% OCP>> INIT CONTROL LEVEL : 5
% OCP>> INIT CONTROL LEVEL : 5
% OCP>> INIT CONTROL LEVEL : 4
% OCP>> INIT CONTROL LEVEL : 3
% OCP>> INIT CONTROL LEVEL : 2
% OCP>> INIT CONTROL LEVEL : 1
% OCP>> INIT CONTROL LEVEL : 0
Note : Above message shown is for TIC `A0 i.e. TIC 01-0. Similar
messages will be repeated for all the TICs.
BASE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 27
3.8.2. Critical Messages Require Appropriate Action
i) In case following messages (Called Recoveries) are coming frequently
on BP Terminal the same should be reported to `CDOT for further
debugging:
Process 180C3783h (code 207) Cmf_Rec_Routine with parameters
1. 39h
2. 0h
3. 1h
EQN : 7044200h
Above recovery indicates that this is related to `DATA and more
specifically due to wrong routing & Trunking data creation on one or
more routes.
Note 1: There can be many such recoveries with different process, code,
rec_routine and parameters Each one of these indicate different
nature of fault. Frequent recoveries may cause the `BM to go for
initialisation with reason SRF counter overflow.
Note 2: However if such recoveries are not frequent then the same can be
ignored.
ii) Whenever some switch unit becomes OOS-SUS, message is flashed on
`BP terminal with its Unit-ID with message MCM_SUS.
These messages are very helpful in debugging switch unit faults.
3.8.3. Message on BP Terminal During Initialization
a) Message : P0-1E
Remarks : Port 0 & port 1 enabled. i.e. both mu-0 & mu-1 are enabled
b) Message : Status 2
Off board out switch over
Remarks : Whichever BP connected to terminal is active and offboard
memory i.e. mu-0/mu-1 not accessible.
c) Message : Change TS 98, 9c, 9e
Remarks : Change Time Switch, path selected is 98,9c,9e i.e., BMS-0,
SCIC-0, TSC-0. Similarly change SCI means SCIC changed,
change MS means BMS changed.
Chapter 3.
28 C-DOT DSS MAX
d) Message : Path 98, 9c, 9e, 66
Path 98, 9c, 9f, 66
Path 98, 9c, 9e, 67
Path 98, 9c, 9f, 67
Remarks : All above are unit ids in Hex. These units are tested for
selecting download path. When any combination of selected
path is ok, down loading starts with message DNLD, ok22K ok
e) Message : LF 98 to 9e
Remarks : LE refers to Link fault. Here it is indicated that, there is link
fault between BMS-0 & TSC-0. Change cards & observe
message again. Similarly link faults will be indicated between
any units with unit ids in Hex.


APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 29
Chapter 4.
Remote Base Module Monitoring
Through BP Terminal
4.1. REMOTE BASE MODULE
Remote Base Module hardware is same as that of a colocated BM except for TSS
card. In RBM TSS card will be replaced by ETS/RTS card. BPU mother jumpers
should be set depending on BM number. ACIO and clock cables, digital trunk cables
should be connected properly as per RSU Installation manual. When RBM is
switched on BP terminal will display messages as follows (No commands need be
given, only communication speed should be 4800/9600 bps depending on type of
processor.)
BP terminal messages given below will be observed with healthy TSC/ETS cards
and if messages are different, change controller cards and observe messages.
Note : For BP cable details refer Fig. 1
Messages on RBM BP Terminal
a) Message : Health log for TSC_0 is 0
Remarks : Health log is 0, TSC card is OK
Message : Health log for TSC_1 is 0
Remarks : Health log is 0, TSC-1 card is OK
b) Message : Health log of RTS_0 is 400
Remarks : Health log is 400. ETS on copy 0 of TSC is OK.
Message : Health log of RTS_1 is 400
Remarks : Health log is 400, ETS copy_1 of TSC is OK.
Chapter 4.
30 C-DOT DSS MAX
c) Message : DTK health log for TSC_0 is 0011111111111111
Remarks : Status of PCMs connected to ETS card in TSU is represented by
16 bits. It is possible to use only maximum of 8 pcms connected
to ETS card in each copy. In the above, 16 bits indicate status of
PCMs.
0 PCM is OK through to main Exchange
1 PCM is down and not through to main Exchange
In the above case 1
st
& 2
nd
PCMs are OK. Remaining 6 are down
or not equipped; last 8 bits can be ignored. RBM digital trunks
counted from 1 to 8 on bus-0 and 17 to 24 on Bus-1 side.
Message : DTK health log for TSC-1 is 1011111111111111
Remarks : In this case RBM dtk 17 is down and dtk18 is OK. Remaining
dtks 19 to 24 are down or not equipped. Ignore last 8 bits.
d) For other messages refer para 3.8.3.
4.2. PROCEDURE TO SEE RBM-DTK (PCM) STATUS
We can see the status of digital trunks (i.e. Dtk or PCM) connected to RBM on BP
terminal. To see the dtk status on BP terminal do the following :
Press Control D
CDOS_02>m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 2> def dtk md @mbc_dtk_link_sta l +20
Logical symbol dtk defined.
MDEB 2>dtk
00CC3086 02 02 02 02 02 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 ..@@@@@
00CC3096 02 02 02 02 02 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 ..@@@@
Table 4.1
Note :
First line shows status of DTK 01 to DTK 08 (BUS-0). (dtks 9 to 16 not used)
Second line shows status of DTK 17 to DTK 24 (BUS-1). (dtks 25 to 32 not used)
In the above example 5 dtks are equipped on Bus0 and 5 dtks are equipped on Bus-
1.
Status of digital trunks of RBM are represented in HEX as given below :
02-> INS-ACT
98-> 00S-SYS
C0-> UNEQUIPPED
REMOTE BASE MODULE MONITORING THROUGH BP TERMINAL
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 31
4.3. PROCEDURE TO SEE RBM-MODE (RBM OR RBMSA)
When all PCMs connected to RBM are down, RBM goes to stand alone mode. On BP
temrinal connected to RBM we can see whether RBM is in RBM mode or RBM
stand alone mode by doing the following :
Press Control D
CDOS 12>m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 2> def mode md @mpi_bm_mode 1+10
Logical symbol MODE defined.
MDEB 2>mode
00CBC6CE 05 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Table 4.2
Note :
1. First byte shows the status of RBM 05RBM mode
06RBMSA mode
2. RBM goes to RBMSA (RBM stand alone) mode when all the dtks (PCMs)
connected to main exchange are down.
4.4. PROCEDURE TO TEST PCM (DTKS) OF RBM USING BP TERMINAL
RBM PCMs (digital trunks) are identified as follows on each copy of TSC.

TSC-COPY dtk id dtk id dtk id dtk id dtk id dtk id dtk id dtk id
TSC-0
(BUS-0)
1 2 3 4 5 6 7 8 9 to 16 not
used
TSC-1
(BUS-1)
17 18 19 20 21 22 23 24 25 to 32 not
used
Table 4.3
TO TEST PCMS DURING INITIAL POWER ON AND BM HAS NOT COME UP:
When RBM is down, BP terminal connected to RBM displays messages as given in
Section 4.1, C. Each PCM can be tested by looping transmit and receive pairs at
different points i.e. RBM site, transmission room DDF, Main Exchange
transmission room DDF, digital trunk cable connector on back plane of CM. Details
of cable termination on connector / DDF are given in RSU installation manual.
Each PCM TX & RX can be looped one by one and fault can be isolated as indicated
in the following section.
Chapter 4.
32 C-DOT DSS MAX
4.5. PROCEDURE TO IDENTIFY PCM FAULTS USING BP TERMINAL BY
LOOPING TX/RX PAIRS AT DIFFERENT POINTS
PCM (dtk) faults connected to RBM may be located by looping TX-a to Rx-a and TX-
b to Rx-b towards RBM from different points in transmission path. This loop
should always be extended towards Remote Base Module and not towards CM.
Status of PCM streams (dtks) may be observed on BP terminal as explained in
section 4.1 or 4.2. Section 4.1 is to be used when RBM is down. Section 4.2 may be
used when RBM is up and few of equipped PCMs (dtks) are down. STatus of PCMs
may be observed by giving loop/break on individual PCMs from different points. By
following steps given below, PCM faults may be localized.

Step TX-RX Loop Point
PCM status after loop on
BP terminal connected to
RBM
Remarks
1 RBM site transmission
room DDF
PCM has come in service Wiring OK upto transmission
room (TX & RX reversal may be
there) GO TO STEP 3
2 RBM site transmission
room DDF
PCM has not come in service Cable Termination fault in
connector, DDF or ulinks in
transmission equipment. Rectify
fault & repeat above step.
3 Main Exchange
Transmission room DDF
PCM has come in service Wiring OK at RBM site & no
interchange of TX-RX at RBM (Tx
& Rx reversal may be there at
Main exchange transmission room
DDF. Go to step 5.
4. Main Exchange
Transmission room DDF
PCM has not come in service Wiring not ok at RBM site
interchange TX & RX at RBM site
DDF only. Interchange TX RX
jumpers at RBM PDF and repeat
the above step.
5. 7 x 3 connector of DTK
cable on back plane of
CM
PCM has come in service Everything OK from transmission
room equipment to RBM site
(Interchange of TX-RX may be
there at Main Exchange
Transmission Room DDF.
Note :
After testing following above steps if PCM is not coming in service after putting
through connector to CM, and comes in service only for Loop from 7 X 3 connector of
DTK cable on backplane of CM, there is interchange of TX-RX pairs at Main
Exchange transmission room DDF. Interchange TX/RX pairs of that particular PCM
and put through the connector to CM. Now verify PCM status on BP terminal and it
should be OK.
REMOTE BASE MODULE MONITORING THROUGH BP TERMINAL
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 33
4.6. PROCEDURE TO IDENTIFY PCM FAULTS WHEN RBM IS ACTIVE
Define the dtk symbol on BP terminal as given in section 3.2 and identify the faulty
PCM id. View the status of the PCM by typing dtk on MDEBxx > prompt. Loop
Tx/Rx of that particular PCM at different points as described in section 4.5 and
view the status of PCM on BP terminal by typing dtk on MDEB xx > prompt, This
process can be repeated until fault is PCM isolated.

34 C-DOT DSS MAX
Chapter 5.
Central Module & Administrative
Module
5.1. CENTRAL MODULE
5.1.1. CM (SSC) Terminal
1. Unit status of CM can be seen from terminal connected to CM CPU.
(i.e. SSC)
2. For BP cable refer Chapter 2
3. (a) For MAX-L connect BP cable to Frame_no:3, slot no: 2A, TAB:1
of CM
(b) For MAX-XL connect BP cable to J25 & J52 (marked as RS-232),
TAB-1 of frame-5 copy-0 and copy-1 of CM.
4. (a) Set baud rate of terminal to 9600 for BPC/HPC
(b) Set baud rate of terminal to 4800 for CPU-S04/CPU-S05.
Numbers in hex representing unit status are given below :
02 INST-ACT 04 INS-SBY 9A-00S-OPR 98-00S-SYS
96 00S-SUS 08 INS-FRC
5.1.2. Procedure to View A Switch Unit Status on SSC Terminal
By defining a symbol on SSC terminal we can see the switch unit status of
CM on SSC terminal. Procedure viewing switch unit status is given below:
Press Control D
CDOS 64_0 >m
### WELCOME TO DD, MDEBUG & RETEST ###
.Type HE for MDEB & HELP for DD help
MDEB 64> def us ca mtdusmap ( )
Logical symbol us defined / redefined .

CENTRAL MODULE & ADMINISTRATIVE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 35
MDEB 64> prn e
MDEB 64> us
Hit Ctrl-C to cancel

CLK/NSC : C0=4 C1=2
SWC_0 : C0 = 2 C1 = 2
SWC_1 : C0 = 2 C1 = 2
SWC_2 : C0 = 2 C1 = 2
SWC_3 : C0 = 2 C1 = 2
SWC_4 : C0 = 2 C1 = 2
SWC_5 : C0 = 2 C1 = 2
SWC_6 : C0 = 2 C1 = 2
SWC_7 : C0 = 2 C1 = 2
SWC_8 : C0 = 2 C1 = 2
SWC_9 : C0 = 2 C1 = 2
SWC_10 : C0 = 2 C1 = 2
SWC_11 : C0 = 2 C1 = 2
SWC_12 : C0 = 2 C1 = 2
SWC_13 : C0 = 2 C1 = 2
SWC_14 : C0 = 2 C1 = 2
SWC_15 : C0 = 2 C1 = 2
SSB/CBX : C0 = 4 C1=2
IFC/CSM_0 : 2
IFC/CSM_1 : 2
IFC/CSM_2 : 2
IFC/CSM_3 : 2
IFC/CSM_4 : 2
IFC/CSM_5 : 2
IFC/CSM_6 : 2
IFC/CSM_7 : 2
IFC/CSM_8 : 2
Chapter 5.
36 C-DOT DSS MAX
IFC/CSM_9 : 2
IFC/CSM_10 : 2
IFC/CSM_11 : 2
IFC/CSM_12 : 2
IFC/CSM_13 : 2
IFC/CSM_14 : 2
IFC/CSM_15 : 2
IFC/CSM_16 : 98
IFC/CSM_17 : 2
IFC/CSM_18 : 2
IFC/CSM_19 : 2
IFC/CSM_20 : 2
IFC/CSM_21 : 2
IFC/CSM_22 : 2
IFC/CSM_23 : 2
IFC/CSM_24 : 2
IFC/CSM_25 : 2
IFC/CSM_26 : 2
IFC/CSM_27 : 2
IFC/CSM_28 : 2
IFC/CSM_29 : 2
IFC/CSM_30 : 2
IFC/CSM_31 : 2
CMS_0 : 2
CMS_1 : 2
CMS_2 : 2
CMS_3 : 2
SSC : C0 = 2 C1 = 4
MEM : C0 = 2 C1 = 2
SWP : C0 = 4 C1 = 2
CENTRAL MODULE & ADMINISTRATIVE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 37
FUNCTION RETURNS ff IN D0
FUNCTION RETURNS 356436 IN A0
Table 5.1
Function call over
MDEB 64 > ex
CDOS 64_0 > ex
Note :
Unit Ids i.e. SWC, IFC, CMS start from zero. Ifc0 in CM terminal is IFC 1 in
Crp terminal. CMS0 in CM terminal is CMS1 in Crp terminal. In the unit
status map CM in Table 4.1, we can see that clk0 is ins-sby, clk1 ins-act, All
switch cards are ins-act.
Copy-0 of the SSBID (CBX) is ins-sby, copy-1 of SSBID (CBX) is ins-active. If
C17 (i.e. Ifc 16 in map is Ifc17 in crp) is oos-sys other Ifcs are ins-act. CMs
1,2,3,4 are active. SSC-0 is ins-act, ssc-1, ins-sby, switch plane (SWP) i.e SS-0
is ins-sby and SS-1 is ins-act.
SWP gives the consolidated status of switch plane. For example if any unit in
SS_0 (SWCX-0, CBX-0, CLK-0) is 00S-SUS, then SWP-0 will also be 00S-
SUS.
5.1.3. Procedure to Modify Switch Unit Status in CM
Press Control D
CDOS 64> m
MDEB 64_1>ca mcm_pus (%UID, %STATUS)
UNIT UID Number in Hex representing Switch unit
Status
SS-0 62 02 INS-ACT 04 INS-SBY
SS-1 63 9A 00S-OPR 98 00S-SYS
SSC-0 64 91 00S-EXT 96 00S-SUS
SSC-1 65
CMS-1 to CMS-4 66 to 69
IFC1 to IFC16 6A to 79
IFC17 to IFC32 7A to 89
CLK-0 8A
CLK-1 8B
SSBID-0 8C
SSBID-1 8D
SWC1-0 SWC16-0
SWC1-1 SWC16-1
Refer to Table 1.1 for Switch Unit ids
Chapter 5.
38 C-DOT DSS MAX

Table 5.2
EX : TO MODIFY IFC-1 STATUS TO 00S-0PR
Derive unit id from table 1.1 for Ifc1.
Press Control D
CDOS 64 > m
MDED 64>ca mcm_pus (%6A, %9A)
MDEB 64>ex
CODS 64> ex
5.1.4. To Modify SRF Counter of CM-CPU
Press control D
CDOS 64> m
MDEB 64> sy mrp_m_ro (To get SRF address)
mrp_m_ro : 0 x 307a78 (SRF address) to this add 600 (in Hex)
307a78 + 600 = 308078 for 2_2_1_6
software.
MDEB 64 > ex
CDOS 64_0 > ex
Press control D
CDOS 64_0 > m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 64 > exm.w 308078
Type CR to skip, space to modify, minus to go back (max = 9)
plus to come back (max = 9), dot to exit
00308078 0064? ffff
0030807A 0030? . (press dot and enter)
MDEB 64>ex
CDOS 64> ex
CENTRAL MODULE & ADMINISTRATIVE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 39
5.1.5. Procedure to See Switch Unit Status in CM By Accessing Processor
(SSC) in CM From IOP Terminal
IOPX > conp
CONP > m 64
### WELCOME TO DD, MDEBUG & RETEST ###
. Type HE for MDEB & HELP for DD help
MDEB 64 > def us md @mcm_usmap l + 50
MDEB 64>def
TAG LOGICAL EQUIVALENCE STRING
0 US md 46a980 l + 50
MDEB 64>us
0044EE0C 04 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 ..
0044EE1C 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 ..
0044EE2C 02 02 04 02 02 02 02 02 02 02 02 02 02 02 02 02 ..
0044EE3C 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 ..
0044EE4C 02 02 02 02 02 02 02 02 02 04 02 02 04 02 00 00 ..
Table 5.3
MDEB 64 > ex
CPM[ > ex
Note : First column of table 5.3 has address. Switch Unit identities to
corresponding position in Table 5.3 from 2
nd
column are given
below in Table 5.4.
Clk-
0
Clk-
1
Swc
1-0
Swc1-1 Swc
2-0
Swc
2-1
Swc
3-0
Swc
3-1
Swc
4-0
Swc
4-1
Swc
5-0
Swc
5-1
Swc
6-0
Swc
6-1
Swc
7-0
Swc
7-1
Swc
8-0
Swc
8-1
Swc
9-0
Swc
9-1
Swc
10-0
Swc
10-1
Swc
11-0
Swc
11-1
Swc
12-0
Swc
12-1
Swc
13-0
Swc
13-1
Swc
14-0
Swc
14-1
Swc
15-0
Swc
15-1
Swc
16-0
Swc
16-1
SSBID
(CBX)
-0
SSBID
(CBX)
-1
Ifc
1
Ifc
2
Ifc
3
Ifc
4
Ifc
5
Ifc
6
Ifc
7
Ifc
8
Ifc
9
Ifc
10
Ifc
11
Ifc
12
Ifc
13
Ifc
14
Ifc
15
Ifc
16
Ifc
17
Ifc
18
Ifc
19
Ifc
20
Ifc
21
Ifc
22
Ifc
23
Ifc
24
Ifc
25
Ifc
26
Ifc
27
Ifc
28
Ifc
29
Ifc
30
Ifc
31
Ifc
32
CMS
1
CMS
2
CMS
3
CMS
4
SSC
-0
SSC
-1
Mu
-0
Mu
-1
SS
-0
SS
-1
-- --
Table 5.3
EX : TO SEE THE SWITCH UNIT STATUS OF SS FROM TABLE 5.3
Referring to Table 5.3 & Table 5.4, we can see that SS-0 is in ins-sby status
and SS-1 is ins-act status.
Chapter 5.
40 C-DOT DSS MAX
5.1.6. To Modify CM Unit Status From IOP Terminal
IOP5X > conp
Conp> m 64
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 64 > m
Buffer size = ? (24 [1], 256[2], 512[3], 1024[4]) (def = 128)
Struct { where
Opcode = mstreq mstreq OOS OPR
Char subfield =1 mswins INS-ACT
Char dummy = mswich INTCHG
Sender_pid =
Mnt_com_hd {
Unsigned short user_id =
Unsigned char session_id =
Unsigned char job_id =
} mci_hdr ;
unsigned char action_cod = 1
unsigned char unit_id = UNIT ID of CM *
} MSTREQ ;
%MDEB-I INFO Send ret. Val=0
MDEB 4>ex
Conp > ex
IOP 5x >
* Ref table 5.2 for CM UNIT ID
** DO NOT MODIFY MU-0, MU-1, SS-0, SS-1
5.1.7. To Check Status of External Clock In CM
After connecting BP Terminal at 'SSC', status of external clocks (RClk0,
Rclk1, Rclk2) can be seen in S/W Release 2_2_1_6.
MDEB_64> md @mcm_clk_status
Alternatively use address to view the status of External Clock in CM
MDEB_64> md 46970a
Byte 0 1 2 3 4 5 6 7 8 9 a b c d e f
Address
DUP
CLK0
RCLK2

RCLK1

RCLK0 USRN -
DUP
CLK1
RCLK2

RCLK1

RCLK0 USRN - - - - -
NSC0 NSC1
CENTRAL MODULE & ADMINISTRATIVE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 41
5.2. ADMINISTRATIVE MODULE
5.2.1. AP Terminal
Switch unit status of AM can be seen from BP terminal connected to CPU of
AM.
For BP cable details, refer fig. No :
a) For MAX-L connect BP cable to Frame No. 4 slot No. 2A, TAB : 1 of
CM CABINET
b) For MAX-XL connect BP cable to BPC-AUX TAB 1 frame 6 of CM of
copy-0 and copy-1. (Refer Chapter 3)
a) Set baud rate of terminal to 9600 for BPC/HPC
b) Set baud rate of terminal to 4800 for CPU-S04/CPU-S05
5.2.2. To View Switch Unit Status in AM
Press Control D
CDOS 56_1 > m
### WELCOME TO DD, MDEBUG & RETEST ###
. Type HE for MDEB & HELP for DD help
MDEB 56>prn e
MDEB 56 > def us ca mtdsmap ()
Logical symbol US redefined
MDEB 56> us
Hit Ctrl-C to cancel
AP : C0 = 4 C1 = 2
MEM : C0 = 2 C1 = 2
IOP : C0 = 2 C1 = 4
ADC : 2
CM : 2
Numbers in Hex representing unit status are given below :
02 INS-ACT 04 INS-SBY 9A-00S-OPR 98-00S-SYS
96 00S-SUS 91-00S-EXT
FUNCTION RETURNS ff IN D0
FUNCTION RETURNS 200148 IN A0
Chapter 5.
42 C-DOT DSS MAX
Function Call over
MDEB 56> ex
CDOS 56> ex
Note : CM : 2 Gives the status of central module.
Status of CM as module 02 Module active
90 Module 00S-INI (out of service under
initialisation)
5.2.3. Procedure to Modify Switch Unit Status in AM
Press control D
CDOS 56 > m
MDEB 56_1>ca mac_pus (% UID % STATUS)

UNIT UID STATUS
AP-0 56 02 INS-ACT
AP-1 57 04 INS-SBY
IOP-0 5C 9A 00S-OPR
IOP-1 5D 91 00S-EXT
ADC 5A 96 00S-SUS
98 00S-SYS
Table 5.1
Ex : To modify status of IOP-0 to 00S-OPR
Press control D
CDOS 56> m
MDEB 56>ca mac_pus (%5C, %9A)
MDEB 56>ex
CDOS 56>ex
Note : DO NOT MODIFY STATUS OF MU-0 & MU-1
5.2.4. Procedure to Modify SRF Counter of AM
Press Control D
CDOS 56>

MDEB 56>sy mrp_m_ro (To get SRF address)
Mrp_m_ro : 0 x 368694 (SRF Address) To this add 600 (in Hex)
If software is 2_2_1_6
368694 + 600 = 368c94
MDEB 56 > exm.w 368c94
CENTRAL MODULE & ADMINISTRATIVE MODULE
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 43
Ex : To modify SRF counter value in AM.
Press Control D
CDOS 56_1 > m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 56> sy mrp_m_ro
Mrp_m_ro : 0 x 368694 Note : To get SRF address add 600 in Hex
to this value ie. 368694 + 600 = 368c94
MDEB 56>exm.w 368c94
TIME IS 31 JAN 2001 12 : 30 : 33
.Type CR to skip, space to modify, minus to go back (max = 9)
.plus to come back (max = 9), dot to exit.
00368C94 0064? ffff
00368C96 0030? . (Press dot and return)
MDEB 56>ex
CDOS 56 > ex .
5.2.5. Procedure to see the ETE of BM with SUM at AP Terminal
With this procedure we can check the ETE of BM with SUM and other details
like BM status, ETE on or off etc from the AP terminal.
Press Control D
CDOS 56_1>m
###WELCOME TO DD, MDEBUG $RETEST###
... Type HE for MDEB &HELP for DD help
MDEB56> def et md @nbm7_data l+c0
Logical symbol et defined
This will give us the map of ETE and other details for all the BMs.

Chapter 5.
44 C-DOT DSS MAX
MDEB56>et


0066E24E 01 00 01 01 01 01 01 01 01 01 01 01 00 00 01 00
0066E25E 00 01 01 00 01 01 01 01 00 00 00 00 00 00 01 00
0066E26E 00 00 01 01 00 00 00 00 00 00 00 00 00 00 00 00
0066E27E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E28E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E29E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2AE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2BE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2CE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2DE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2EE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2FE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

On this MAP six bytes represent one BM, which are explained below with
possible values.
Pos. Value Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 & Byte6
00 BM
Down
Non-
Home BM
CCS#7
Trks
Absent
ETE off
BM Unequipped
01 BM UP Home BM CCS#7
Trks
Present
ETE On BM equipped
With the above MAP we can able to see the details of every BMs like BM is
Active or in OOS-INI, whether the Trunk BM is Home BM or Non Home BM
with CCS#7 trunks available or not. Finally the fourth bite is more helpful to
check the ETE {End-to-End link) of BM with SUM is ON or OFF.
In case of BM is not equipped all the bytes will be shown as 00.
For local and remote line BM bytes 2, 3 and 4 will have a value 00.
5.2.6. Address for SRF Counters in Various Configurations
Please refer Annexure I for the details of symbols and addresses.

BM-01 BM-02 BM-03
BM-32 BM-31 BM-30

APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 45
Chapter 6.
Signaling Unit Module (CCS7 Module)
6.1. INTRODUCTION
The SUM BP cable details are given in Figure 2.3. Set the baud rate for 9600 and
connect bp cable to SLOT No. 5 connector A tab 2 position of SUM frame.
6.1.1. PROCEDURE TO SEE THAT ETE WITH SUM TO OTHER BMS
HAVING #7 TRUNKS.
Sum communicates with other BMs & Home BM (BM in which SUM is
Equipped) on c.85 links. These C.85 links are nailed up through PHC
timeslots (channel). By defining a symbol et, we can find out which PHC time
slot is used by SUM to nail up C.85 links towards BPs of BMs having No. 7
trunks.
Press control D (Note : Each time when not required exit from MDEB5e> &
CHAOS 5e>
Prompt by giving ex
CHAOS : 5E_0>m
### WELCOME TO DD, MDEBUG & RETEST ###
. Type HE for MDEB & HELP for DD help.
MDEB 5e > def et md @nrwdatabase +1d00 l +80
Logical symbol ET defined.
MDEB 5e>et
BM-1 BM-2 BM-3 BM-4
005EE2DA 00 00 FF 00 00 01 FF 00 00 02 49 00 00 03 FF 00
005EE2EA 00 04 FF 00 00 05 FF 00 00 06 6A 00 00 07 FF 00 For BM5 to BM8
005EE2FA 00 08 2A 00 00 09 FF 00 00 0A 5A 00 00 0B FF 00 For BM9 to BM12
005EE30A 00 0C 0D 00 00 0D FF 00 00 0E FF 00 00 0F FF 00 For BM13 to BM16
005EE31A 00 10 0A 00 00 11 FF 00 00 12 FF 00 00 13 FF 00 For BM17 to BM20
005EE32A 00 14 4D 00 00 15 FF 00 00 16 FF 00 00 17 FF 00 For BM21 to BM24
005EE33A 00 18 2E 00 00 19 FF 00 00 1A FF 00 00 1B 6E 00 For BM25 to BM28
005EE34A 00 1C FF 00 00 ID 3A 00 00 1E 09 00 00 1F 5E 00 For BM29 to BM32
Table 6.1
Chapter 6.
46 C-DOT DSS MAX
MDEB 5e > ex
Chaos 5E > ex
Note : In the above example 11 BMs are having ETE with SUM all BM
Nos are logical numbers. BMs having ETE is allotted with phc
channel number otherwise it is marked as FF.
Leaving the first column which has address, other columns can be counted
from 1 to 16. Columns 2,6,10,14 have the BM Nos and columns 3,7,11,15
have PHC channel nos. allocated for that corresponding BM No.
PHC card slot and corresponding channel numbers in hex are indicated in
table 6.2 below.
PHC-CARD (Slot No.) Channel No.
7 08 to 0f
8 18 to 1f
9 28 to 2f
10 38 to 3f
17 48 to 4f
18 58 to 5f
19 68 to 6f
20 78 to 7f
Table 6.2
Ex : In the above table 6.1 BM-03 is having ETE with SUM through 49, BM-9
(Logical No. 08) is having ete with sum through PHC channel 2A so on.
6.1.2. Alternative Procedure to see the ETE of BM with SUM at AP
Terminal
With this procedure we can check the ETE of BM with SUM and other details
like BM status, ETE on or off etc from the AP terminal.
Press Control D
CDOS 56_1>m
###WELCOME TO DD, MDEBUG $RETEST###
... Type HE for MDEB &HELP for DD help
MDEB56> def et md @nbm7_data l+c0
Logical symbol et defined
This will give us the map of ETE and other details for all the BMs.

SIGNALING UNIT MODULE (CCS7 MODULE)
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 47
MDEB56>et !


0066E24E 01 00 01 01 01 01 01 01 01 01 01 01 00 00 01 00
0066E25E 00 01 01 00 01 01 01 01 00 00 00 00 00 00 01 00
0066E26E 00 00 01 01 00 00 00 00 00 00 00 00 00 00 00 00
0066E27E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E28E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E29E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2AE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2BE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2CE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2DE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2EE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0066E2FE 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

On this MAP six bytes represent one BMs, which are explained below with
possible values.
Pos. Value Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 & Byte6
00 BM
Down
Non-
Home BM
CCS#7
Trks
Absent
ETE off BM unequipped
01 BM UP Home BM CCS#7
Trks
Present
ETE On BM equipped
With the above MAP we can able to see the details of every BM like BM is
Active or in OOS-INI, whether the Trunk BM is Home BM or Non Home BM
with CCS#7 trunks available or not. Finally the fourth bite is more helpful to
check the ETE {End-to-End link) of BM with SUM is ON or OFF.
In case of BM is not equipped all the bytes will be shown as 00.
For local and remote line BM bytes 2, 3 and 4 will have a value 00.
6.2. PROCEDURE TO SEE THE TERMINAL TABLE OF SUM
Press control D
CHA0S : 5E>m
BM-01 BM-02 BM-03
BM-32 BM-31 BM-30
Chapter 6.
48 C-DOT DSS MAX
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 5e> def tt md @terminal_table l + 80
Logical symbol TT redefined.
MDEB 5e>TT
005F500E 09 FC 08 FC 0A FC 0B FC 0C FC 0D FC 0E FC 0F FC
005F501E 28 FC 29 FC 2A FC 2B FC 2C FC 2D FD 2E FC 2F FC
005F502E 38 FC 39 FC 3A FC 3B FC 3C FC 3D FC 3E FC 3F FD
005F503E 48 FC 49 FC 4A FD 4B FD 4C FC 4D FC 4E FC 4F FC
005F504E 58 FC 59 FD 5A FC 5B FC 5C FC 5D FC 5E FC 5F FC
005F505E 68 FC 69 FC 6A FC 6B FD 6C FC 6D FC 6E FC 6F FC
005F506E 78 FC 79 FC 7A FC 7B FD 7C FC 7D FC 7E FC 7F FD
005F507E FF FE FF FE FF FE FF FE FF FF FF FF FF FE FF FE
Table 6.3
The above Table shows allocation of phc channels. From this table 6.3 we can
determine how many phc channels are being used.
Status is represented as follows :
FC USED
FD FREE
Ex : To know status of PHC channel in PHC slot 7 in sum channel numbers
for slot 7 is 08 to Of (table 6.2). From table 6.3 we can locate 08 to Of are in
first line and are allocated. Channel 09 has fc against it and hence it is
allocated.
6.3. PROCEDURE TO SEE NUMBER OF FREE PHC CHANNEL AVAILABLE
FOR C.85
CHAOS:5E>m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help.
MDEB 5e>def free md @ int_free_trm l + 10
Logical symbol FREE defined.
MDEB 5e> free
005EEA30 02 00 00 00 00 00 09 00 00 14 00 00 00 00 00 81 ..
MDEB5e > ex
CHAOS5e> ex
Table 6.4
SIGNALING UNIT MODULE (CCS7 MODULE)
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 49
Note: After typing free on MDEB prompt, response will be as given in table 6.4.
First column has address 2
nd
column has value 02 which indicates that no. of
free PHC channels available for C.85 link is 2.
6.4. PROCEDURE TO SEE NUMBER OF FREE PHC CHANNEL AVAILABLE
FOR #7 IN FREE POOL
(not allocated at present)
CHAOS:5E>m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 5e> def n7 md @no7_free_trm l+10
Logical symbol N7 redefined.
MDEB 5e>n7
005EF6EE 06 00 B0 00 40 00 00 00 00 00 00 00 00 00 00 00 ..0.@
MDEB5e > ex
CHAOS5e> ex
Table 6.5
Note :
On typing n7 on MDEB prompt, response will be as given in table 6.5. First
column has address. 2
nd
column has value 06, which indicates that no. of free phc
channels for no.7 links is 6.
6.5. PROCEDURE TO SEE HOME ACTIVE CHANNEL (C.85) FOR HOME BM
Press Control D
CHAOS : 5e>m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 5e> def hc md @ home_i_channel l + 10
Logical symbol HC defined.
MDEB5e> hc
005F09F2 09 00 08 00 00 00 00 00 00 00 00 00 00 00 00 00 .
MDEB5e > ex
CHAOS5e> ex
Table 6.6
Note : In this channel 09 is used for SUM to Home BM ETE.
Chapter 6.
50 C-DOT DSS MAX
6.6. PROCEDURE TO SEE STANDBY CHANNEL (C.85) FOR HOME BM
Press control D
CHAOS : 5E>m
### WELCOME TO DD, MDEBUG & RETEST ###
Type HE for MDEB & HELP for DD help
MDEB 5e> def sb md @sby_i_channel l+10
Logical symbol SB defined.
MDEB 5e>sb
005FBACF 7D 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 }..
MDEB5e > ex
CHAOS5e> ex
Table 6.7
Note :
Standby phc channel for communication on C.85 link with home BM is 7d as in 2
nd

column of table above (6.7).


51 C-DOT DSS MAX
Chapter 7.
V5.X Unit
7.1. INTRODUCTION
The VU BP cable details are given in Figure 2.3. Set the baud rate for 9600 and
connect BP cable to SLOT No.5 connector A tab 2 position of VU frame (same as in
case of SUM).
7.1.1. Procedure to See the ETE of VU with Home BM
Press control D
PERIOS 91_CC_0 >
PERIOS 91_CC_0 > m
### WELCOME TO DD, MDEBUG & RETSET ###
.Type HE for MDEB & HELP for DD help.
MDVU 91 > def et ete 166 s
Logical symbol ET defined
MDVU 91 >et
ENDNO STATUS EDTMR RCR TMR TOC REJ INI ETR EOF
166 1 28 N N N N N N Y
Table 7.1
Note: If there is ETE between BP and VU then all fields will be N except
EOF as shown above in table 7.1 .
Chapter 7.
52 C-DOT DSS MAX
PHC card slot and corresponding channel numbers in hex are indicated in
table 7.2 below
PHC-CARD (Slot No.) Channel No.
7 08 to 0f
8 18 to 1f
9 28 to 2f
10 38 to 3f
11 48 to 4f
12 58 to 5f
13 68 to 6f
14 78 to 7f
Table 7.2
7.2. PROCEDURE TO SEE THE TERMINAL TABLE OF VU
Press control D
PERIOS 91_CC_0 > m
### WELCOME TO DD, MDEBUG & RETSET ###
.Type HE for MDEB & HELP for DD help
MDVU 91 > def tt md @ terminal_table l+80
Logical symbol TT defined
MDVU 91 >TT
0061620E 09 FC 08 FD 0A FD 0B FD 0C FC 0D FC 0E FD 0F FD
0061621E FF FE FF FE FF FE FF FE FF FE FF FE FF FE FF FE
0061622E FF FE FF FE FF FE FF FE FF FE FF FE FF FE FF FE
0061623E FF FE FF FE FF FE FF FE FF FE FF FE FF FE FF FE
0061624E FF FE FF FE FF FE FF FE FF FE FF FE FF FE FF FE
0061625E FF FE FF FE FF FE FF FE FF FE FF FE FF FE FF FE
0061626E FF FE FF FE FF FE FF FE FF FE FF FE FF FE FF FE
0061627E FF FE FF FE FF FE FF FE FF FE FF FE FF FE FF FE
Table 7.3
The above table shows allocation of PHC channels. From this table 7.3 we can
determine how many PHC channels are being used.
V5.X UNIT
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 53
MDVU 91 > ex
PERIOS 91_CC_0 > ex
Status is represented as follows
FC USED
FD FREE
Ex. To know status of PHC channel in PHC slot 7 in VU channel numbers for slot 7
is 08 to 0F (table 7.2). From table 7.3 we can locate 08 to 0F are in first line and are
allocated.
Channel 09 has FC against it and hence it is allocated.
7.3. PROCEDURE TO SEE NUMBER OF FREE PHC CHANNEL AVAILABLE
FOR C.85
Press control D
PERIOS 91_CC_0 > m
### WELCOME TO DD, MDEBUG & RETSET ###
.Type HE for MDEB & HELP for DD help
MDVU 91 > def free md @int_free_trm l+1
Logical symbol FREE defined.
MDVU 91 > free
00615ADE 02
MDVU 91 > ex
PERIOS 91_CC_0 > ex
Note :
After typing free on MDVU prompt, response will show the decimal value, i.e., 02
which indicates that no. of free PHC available for C.85 link is 2
7.4. PROCEDURE TO SEE NUMBER OF FREE PHC CHANNELS AVAILABLE
FOR V5.2 IN FREE POOL
Press control D
PERIOS 91_CC_0 > m
### WELCOME TO DD, MDEBUG & RETSET ###
.Type HE for MDEB & HELP for DD help
MDVU 91 > def v5 md @v5_free_trm l+1
Logical symbol V5 defined.
MDVU 91 >v5
0061A924 03
Chapter 7.
54 C-DOT DSS MAX
MDVU 91 > ex
PERIOS 91_CC_0 > ex
Note :
On typing V5 on MDVU prompt, response will show the decimal value, i.e., 03 which
indicates that no. of free PHC channels available for V5.2 in free pool is 3.
7.5. PROCEDURE TO SEE HOME ACTIVE CHANNELS (C.85) FOR HOME BM
Press control D
PERIOS 91_CC_0 > m
### WELCOME TO DD, MDEBUG & RETSET ###
.Type HE for MDEB & HELP for DD help
MDVU 91 > def hc md @home_i_channel l+1
Logical symbol HC defined.
MDVU 91 >hc
006161F3 09
MDVU 91 > ex
PERIOS 91_CC_0 > ex
Note :
In this, channel 09 is used as active C.85 channel.
7.6. PROCEDURE TO SEE STANDBY CHANNEL (C.85) FOR HOME BM
Press control D
PERIOS 91_CC_0 > m
### WELCOME TO DD, MDEBUG & RETSET ###
.Type HE for MDEB & HELP for DD help
MDVU 91 > def sb md @sby_i_channel l+1
Logical symbol SB defined.
MDVU 91 >sb
0061A937 0D
MDVU 91 > ex
PERIOS 91_CC_0 > ex
Note :
In this, channel 0D is used as standby C.85 channel.
V5.X UNIT
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 55
7.7. PROCEDURE TO SEE STATUS OF VU ON BP-TERMINAL
After connecting BP-cable to the proper position on BM, on MDEB, we define the
following string
MDEBXX > def stat md @mbc_bm_unit+CC l+4
00CC32C2 02 04 02 02
The first 02 stands for VU-0 copy and 04 stands for VU-1 copy.
Similarly the next two 02s stand for VMU-0 and VMU-1 respectively.
MDEBXX> ex
MDEBXX> ex


APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 56
Chapter 8.
Input Output Module (IOP)
8.1. INTRODUCTION
In this chapter, following are discussed.
Procedure to use sbyupd utility to change switch unit status in IOP
Procedure to derive address for required symbols from IOP for BP terminal
operations
8.2. SBYUPD UTILITY
Some time module under initialisation (say BM) may not come up because down
loading path is not available through healthy switch units. For example, when BM
is down, BM may not come up because TSC-0 is in oos-opr status and TSC-1 path
may not be ok. In such situations, it is required to correct the status of TSC. We
may correct status of switch units as TSC-0 as ins-act and TSC-1 as ins-sby. After
correcting the status of switch units, AM and concerned module is to be initialised
to part-init or above.
PROCEDURE TO USE SBYUPD UTILITY
Utility is menu driven and all switch unit identities are to be entered in
Hexadecimal. Switch unit ids in Hex may be derived from table 1.1. Before invoking
utility note down total no. of switch units and their ids in HEX whose status is to be
corrected. Unit status available in file apunit.bin is to be edited by choosing
respective module.
Ex : BM-01 is under initialisation and not recovering. On seeing displ-sys-all in
growth mode in active IOP, TSC-0 is in oos-opr and TSC-1 is ins-act. Now, there
may be problem in TSC-1 and system is not able to select TSC-0 path because TSC-
0 is oos-opr. Now it is desirable to correct TSC-0, TSC-1 status as ins-act, ins-sby
respectively, so that system can recover from alternate path. Now switch off both
BPU power supplies of BM-01. If IOPs are in duplex bring stand by IOP to warm
start and then active IOP to warm start. Edit the switch unit status of TSC-0, TSC-
1 in last active IOP (now in warm start) using sby upd utility as follows :
Iop 5x > cd $ PRCDATAP
Iop 5x > pwd
INPUT OUTPUT MODULE (IOP)
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 57
/data / exdata / prcdata
iop5x > sbyupd
Welcome to RETROFIT UNIT STATUS MANAGEMENT SYSTEM
Input file name of unit status : apunit.bin
What LINK SBM/MBM (S/M) : m
Module to be updated / viewed
(CAM/IOM/BM-01 to BM-32/CM/SUM/ALL) : BM-01
MAIN MENU
Select your option
1. View default units
2. Update default units
3. View certain unit status data
4. Update certain unit status data
5. Do updations for some other module
6. Quit (without write)
7. exit
Option : 4
How many units to be updated : 2
INPUT UNIT TO BE UPDATED : value in hex eg. 96,9e,9f etc. : 9e
INPUT STATUS TO BE UPDATED : (eg. 2, 9a) : 02
INPUT UNIT TO BE UPDATED : 9f
INPUT STATUS TO BE UPDATED (eg. 2, 9a) : 04
Note :
Now main menu appears and choose exit option from main menu.
Option : 7
Iop5x> crp
Now change iop mode from online to growth mode. With displ-sys-all command for
BM-01 we can see that TSC-0 is ins-act and TSC-1 as ins-sby. Now IOP has proper
status and go back to on line mode. Now AM is to be initialized to part init from AP
terminal connected to APU. If AP terminal is not available give reset to both copies
of AP. Now system will be down & MLF appears on ADP. Last active IOP where
unit status is corrected can be brought ins-act by command init-iop : 5,1;
Chapter 8.
58 C-DOT DSS MAX
Now IOP will become active, AM goes for part init or code load (if reset given to
both APs), all BMs go for stable clear & system recovers. Switch on the BM-01 and
BM-01, should come up after code load.
Note :
This procedure involves down time and may be carried out during slack hours.
8.3. PROCEDURE TO DERIVE ADDRESS FOR REQUIRED SYMBOL FROM
IOP TERMINAL FOR USE WITH BP TERMINAL
Procedure to derive address for required symbol for MBM 2_2_1_6 link is given
below.
Address can be obtained from different files in directory / code / abpexe for different
module as given below. Response for grep command will give the address. Please
note that address can be different with different software releases whereas symbols
remain same. It is advisable to derive address from IOP and use it.
For AP/SSC
Iop5x > grep mrp_m_ro / code / abpexe / napxxxsys.map
mrp_m_ro 0 x 368694 - For AP
Note : Address for symbol mrp_m_ro is 368694 for AP

IOP5x> grep mrp_m_ro / code / abpexe / sscxxxsys.map
mrp_m_ro 0 x 307a78 - For SSC
Note : Address for symbol mrp_m_ro is 307a78 for SSC.
iop5x > grep mcm_usmap / code / abpexe / sscxxxsys.map
mcm_usmap 0 x 46a980 For im
iop5x >grep mcm_clk_status /code/apexe/sscxxxsys.map
mcm_clk_status ox46970a
For BM (colocated/RBM)
Iop5x > grep mbc_bm_unit /code/abpexe/nbpxxxsys.map
mbc_bm_unit oxcc3202
iop5X> grep mrp_m_ro / code / abpexe / nbpxxxsys.map
mrp_m_ro o x 5b1542
iop5x> grep mda_print_flag / code / abpexe/nbpxxxsys.map
mda_print_flag 0 x cc6fa4
For RBM
iop5x> grep mbc_dtk_link_sta / code / abpexe / nbpxxxsys.map
mbc_dtk_link_sta 0 x cc3086
INPUT OUTPUT MODULE (IOP)
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 59
iop5x> grep mpi_bm_mode / code / abpexe/nbpxxxsys.map
mpi_bm_mode 0 xcbc6ce
For SUM
Iop5x> grep nrwdatabase / code / abpexe / nnpxxxsys.map
nrwdatabase 0 x 5ec5da
Iop5x> grep terminal _ table / code / abpexe / nnpxxxsys.map
Terminal_table 0 x 5f500e
Iop5x > grep int_free_trm / code /abpexe/nnpxxxsys.map
Int_free_trm 0 x 5eea30
Iop5x>grep no7_free_trm /code/abpexe/nnpxxxsys.map
No7_free_trm 0 x 5ef6ee
Iop5x> grep home_i_channel /code/abpexe/nnpxxxsys.map
Home_i_channel 0 x 5f09f2
Iop5x> grep sby_i_channel / code / abpexe/nnpxxxsys.map
Sby_i_channel 0 x 5fbacf
For VU
IOP5x>grep terminal_table /code/abpexe/nvpxxxsys.map
terminal_table 0x61620e
IOP5x>grep int_free_trm /code/abpexe/nvpxxxsys.map
int_free_terminal 0x615ade
IOP5x>grep v5_free_trm /code/abpexe/nvpxxxsys.map
v5_free_trm 0x61a924
IOP5x>grep home_i_channel /code/abpexe/nvpxxxsys.map
home_i_channel 0x6161f3
IOP5x>grep sys_i_channel /code/abpexe/nvpxxxsys.map
sys_i_channel 0x61a937


APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 60
Chapter 9.
Health Log & Field Debugging Tool
9.1. PROCESSING HEAL LOG FILES
Note :
Processing of Health log is not required during normal maintenance
schedule. It can be done only in consultation with C-DOT.
Heal logs are health log reports of BM, this can be enabled by modifying system-
parameter HEAL-LOG-ENBL to 255 by CRP command. This parameter can be
disabled by modifying HEAL-LOG-ENBL to 0, it is common for all BMs. SUM
heal logs are always enabled.
System generates heal logs for all BMs in separate file.
These files are available in IOP in $FDTDIR directory in healXXmmdd.format
Where XX = BM_ID For SUM it is 2f
mm = current month
dd = current date
Procedure to see recoveries through crp using heal log
System parameter 'Heal-log-enable' should be modified to .255
IOP5X> cd $FDTDIR
IOP5X>ls - ls heal*
Module File Name
AM heal2bddmm
SUM heal2fddmm
BM healXXddmm (where XX is logical BM No.)
CM heal32ddmm
IOP 5X> cd $FDTDIR
IOP5X> hlpp -P <heal file Name>
eg. hlpp .P heal2f2110 (for heal log of SUM of 21-10-02)
HEALTH LOG & FIELD DEBUGGING TOOL
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 61
Choose option for 'Process Recovery' using J&K keys and press '+' to highlight
and 'X' to exit. To select all press 'a' and 'x'.
An o/p file healxxddmm.rep will be generated. This file can be paged to
check for recoveries type.
To enable heal log for CM, do following:
MDEB64>exm.b 2e2a56
Modify from 00 to ff.
Note : Address of heal_log_enable can be taken using "sy
heal_log_enable" on mdeb_64> prompt.
9.2. PROCEDURE TO START AND PROCESS FDT
FDT is FIELD DEBUGGING TOOL this is used to find out the reasons for
recoveries and other failures.
Note : FDT is used for specific problems only and is not required during normal
maintenance.
1. Copy of the required FDT file in $FDTDIR directory
2. Compile the file fdtl file_name this generates object file filename.O
3. If there is no compilation error proceed further
4. From IOP terminal go to CONP
Ex : iop5C > fdtl filename
Iop5c > filename.O
9.3. PROCEDURE TO START FDT & VIEW FDT STATUS
IOP5X> cd $FDTDIR
IOP5X> pwd
/u/fdt/test
Copy fdt script file (say abc.fdt) in this directory.
Compile fdt script file 'abc.fdt' by giving
IOP5X>fdtl abc
IOP5X. conp
CONP> fdt xx (when xx is BP ID of module)
FDT XX> start abc
Give 'user name'. Password is default.
Now 'fdt' will be started on the module xx.
FDT xx> exit (To come out of FDT prompt to IOP5X>).
Once observation is taken for required period, one has to stop the fdt session.
Go to FDT xx> prompt again
Chapter 9.
62 C-DOT DSS MAX
FDT xx> quit (To quit FDT session)
Output of 'FDT' will be available in abc.log file, same has to be post processed by
giving
IOP5X>pp -P abc
Output of this post processing will be stored in abc.pri, which can be paged using
'pg' or 'cat'.
In between, if one wants to check whether 'FDT' session is running or not, give
following command
IOP5X> conp
CONP> fdt xx
FDT xx> ses
This will show the name of the 'FDT' script file running at that time.
9.4. PROCEDURE TO COPY FILES FROM BMDC/ED/BD
Many a times fresh files are required to be copied from BMDC or old files to be
restored from ED/BD
Suppose apgpa.dat, apgpa.idx, apgpa.lok files are to be copied from BMDC to Disk
in $GLBDATAP.
IOP5X>cd $GLBDATAP
IOP5X>cp apgpa* /u/admn
IOP5X>rm apgpa*
IOP5X> cd /
Now Insert 'BMDC' cartridge
IOP5X>cpio -icvdu *apgpa* <$TAPE
It must show 3 files (apgpa.dat, apgpa.idx and apgpa.lok) and then total Block size
of BMDC
IOP5X>cd $GLBDATAP
IOP5X>ls -ls apgpa* (To verify the files)
9.5. PROCEDURE TO INSTALL & CHECK PPL
9.5.1. Procedure to Install PPL
Copy PPL files in $HPCHP directory
IOP5X>cd $HPCHP
IOP5X>pwd /to verify/
It shows /code/wpch
Insert 'PPL' cartridge in IOP.
IOP5X>cpio -icv <$TAPE
IOP5X>ls -ls
HEALTH LOG & FIELD DEBUGGING TOOL
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 63
It shows files 'say' hmplatf, pmplatf & its log file (say mbm_altf.log)
Now go to crp & give following command
<instl-ppl
[PCH-LNK] = < >
[PM-NO] = < >
[BM-NO] = < >
and execute to remove all the previous existing PPL (if installed)
Again give the command
[PCH-LNK] = altf
[PM-NO] = < >
[BM-NO] = < >
and execute
Keep giving return to come out to crp prompt,
Caution : In case any BM is down (OOS-INI), then in parameter [BM-NO],
write exact BM Nos e.g. 1&2&3.... etc skipping the 'OOS-INI' BM No.
9.5.2. Procedure to Check Proper Installation of the Patch
Procedure - 1
IOP5X>cd $PRCDATAP
IOP5X>od -cx pplf
or
IOP5X>od -bc pplf
This will show PPL name (e.g. altf in above case) in the first line. This will
confirm that ppl altf has been installed.
Procedure - 2
For this procedure, 'ppl' log files must be available in the 'ppl' cartridge
i) IOP5X>cd $HPCHP
IOP5X>vi mbm_altf.log
Following are the contents:
Patch : mst : file=vpc1pcs_sto7_chk_pndng_msg.c Maptable=cpmap
*********MESSAGE********
Function : clp_sto7ckk_pndng_msg
Process : vp
Old address : 0x48ad50
New address: 0x7a1802
Map_table_index:164
Map_table_address:4638bc
Note down value of index, New address & Maptable (say cpmap).
Chapter 9.
64 C-DOT DSS MAX
ii) On 'BP' terminal, give following:
MDEB>md @cpmap+4*(Index Value)
eg. in above case, give:
MDEB> md @cpmap+4*164
In the memory dump, compare 1st sixe bytes, which should match with
the value of new address. Otherwise the 'ppl' has not been installed
properly.
9.6. PROCEDURE FOR TRANSFERING FILES FROM IOP TO PC AND VICE-
VERSA
Introduction: There are two utilities namely 'rz' and 'sz' present in directory
$TOOLP which are used to transfer the files from IOP to PC/LAPTOP and vice-
versa.
1. 'rz' is the utility to transfer the file from PC/Laptop to IOP
2. 'sz' is the utility to transfer the file from IOP to PC/Laptop.
PROCEDURE : For using the 'rz' and 'sz' utilities follow the procedure given
below.
Copy the 'rz' and 'sz' utilities in $TOOLP directory in IOP.
Connect the com port (say com2) of PC/Laptop to ASIO port of IOP using RS-
232 cable having female connector on both side.
Go to Hyperterminal option on the PC/Laptop available in Accessories.
In the top menu of Hyperterminal, click on 'file' and select the 'properties' to
change the setting of Hyperterminal. Select Port as 'COM2' and click on
'configure'. In the port setting of 'COM2' give the following values for the
given parameters
(a) Bits per second = 9600
(b) Data bits = 8
(c) Parity = None
(d) Flow control = None
Click 'OK' after setting all these parameter. Now click 'Setting' and select
'Emulation' as 'VT100' and click 'OK'.
After connecting the cable and changing the setting the above setting login
prompt will be obtained on the Hyperterminal.
Login as 'admn' and password as 'CDOTadmn'
The file from IOP to PC/LAPTOP can be transferred by using the 'sz' utility.
For this run the following command at IOP prompt:
HEALTH LOG & FIELD DEBUGGING TOOL
APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 65
IOP5x> sz filename
This will transfer the file from IOP to Hyperterminal(PC/Laptop).
The file from PC/LAPTOP to IOP can be transferred by using the 'rz' utility.
For this run the following command at IOP prompt:
IOP5x> rz
In the top menu of Hyperterminal, click on 'transfer' and select the 'send file'.
A browser window will get opened. Select the Protocol as 'Z modem' and the
file name to be transferred to IOP.
Cable Preparation
1. RS-232 cable having female connectors on both sides should be used.
2. Pin connection for cable should be 2-3, 3-2, 5-5.
3. Pin no 1-4-6 should be shorted both sides.


APPLICATION NOTE ON BASE PROCESSOR TERMINAL COMMANDS 66
Annexure I
Symbols and Addresses for Various
Function
Module Function Symbol 2_1_1_1 2_2_1_3 2_2_1_4 2_2_1_6
AP SRF Counter mrp_m_ro+600 348bb2 368c94 398c94 368c94
SRF Counter mrp_m_ro+600 2e8040 308078 308078 308078
Status Map mcm_usmap 44ee0c 46f5b4 46a980 46a980
CM
External Clk Sts. mcm_clk_status 44dcb8 46e33e 46970a 46970a
Status Map mbc_bm_unit 9ec332 ca2948 ca2d58 cc3202
SRF Counter mrp_m_ro+600 4ad260 591928 591928 5b1b42
DGN Print mda_print_flag 9ed228 ca66de ca6aee cc6fa4
DTK Status mbc_dtk_link-st 9ec192 ca27cc ca2bdc cc3086
BM/RBM
RBMSA Mode mpi_bm_mode 9e0422 c9be14 c9c224 cbc6ce
BM ETE Status nrwdatabase 5c64b0 5cc51a 5ec5da 5ec5da
PHC Trml Alloc. terminal_table 5cf840 5d4f4e 5f500e 5f500e
Free C.85 Trml int_free_trm 5c882e 5ce970 5eea30 5eea30
Free Trml no7_free_trm 5c8ef8 5cf62e 5ef6ee 5ef6ee
Home Act C.85 home_i_channel 5c9410 5d0932 5f09f2 5f09f2
Home Sby C.85 sby_i_channel 5d40f4 5dba0f 5fbacf 5fbacf
SUM
Status Map mpi_unit_stat_m 0204a4 023cee 023cee 023cee
PHC Trml Alloc. terminal_table - 5f84ba 5f851e 61620e
Free C.85 Trml int_free_trm - 5f7d8a 5f7dee 615ade
Free Trml v5_free_trm - 5f842e 5fcc34 61a924
Home Act C.85 home_i_channel - 5f849f 5f8503 6161f3
VU
Home Sby C.85 sby_i_channel - 5fcbe3 5fcc47 61a937
Note: The addresses for the various mrp_m_ro (SRF Addresses) here given after adding
600 (in HEX) to the addressed value.

You might also like