You are on page 1of 1

Production Status: Available for sale to all U.S. customers.

s. Please check with your local Emerson Climate Technologies representative


for international availability.
HCFC, R-22, Mid Point, 60 Hz, 3 - Phase, 200/230 V
CR37KQ-TF5
Power (Watts):
Current (Amps):
EER (Btu/Wh):
Mass Flow (lbs/hr): 535.0
10.4
10.2
3500 2980
9
15.7
600.0
Overall Length (in):
Overall Width (in):
Overall Height (in):
9.25
14.25
7.5
7.5
Mounting Height (in): 14.625*
Mounting Width(in):
Mounting Length (in): 9.25
0.673 Stroke (in):
46700 36400 Capacity (Btu/hr):
Bore Size (in): 1.96 Displ (ft^3/hr): 493.5263
4.061 Displ (in^3/Rev): 2 Number of Cylinders:
65/85 65/115
Mechanical Performance
Sound Power(dBA):
Vibration (mils(peak-peak)):
75 Ave 80 Max
2.2 Ave 3.2 Max 40
38 Oil Recharge (oz):
Initial Oil Charge (oz):
Discharge Size (in):
Suction Size (in):
66.0 Net Weight (lbs):

15.5 MCC (Amps):
RPM:
CSA File No.:
85.0
LRA-Half Winding:
LRA-High*:
LRA-Low*:
UL File Date:
UL File No.:
Electrical
Max Operating Current:
45/100 45/130
3/8 Stub
3/4 Stub
Air Conditioning
Evap(F)/Cond(F)
RG(F)/Liq(F)
375.0 Internal Free Volume (in^3):
*
HorsePower
*Low and High refer to the low and high nominal voltage ranges for which the motor is approved.
Overall compressor height on Copeland Brand Product's specified
mounting grommets.

RLA(=MCC/1.4; use for contactor selection): 11.1
RLA (=MCC/1.56; use for breaker & wire size selection): 9.9

1998-01-30 Record Date:
Alternate Applications
Application Voltage Phase Refrigerant Frequency(Hz)
200/230 3 R-22 HCFC 60
200/230 3 R-22 HCFC 60 High Temperature
200/240 3 R-22 HCFC 50
200/240 3 R-22 HCFC 50 Air Conditioning
200/240 3 R-22 HCFC 50 High Temperature
Paul, Fisco.
Page 1 of 1
7/22/2009
Copyright 2008 Emerson Climate Technologies, Inc. All rights reserved.