Professional Documents
Culture Documents
Hspaoptimizationdochuawei
Hspaoptimizationdochuawei
CE Overbooking
HSDPA Scheduling Based on UE Location
HSDPA Scheduling Based on UE Location
During field test, after activates the new features above, UL throughput slightly degrades, but UL
throughput is more stable than ever before; and DL throughput improves. Two new features are available
starting from RAN 14. Considers the network will upgrade to RAN14 in the near future, we integrate them
into the solution:
Several reserved parameters below are profitable to maintain the KPI[5] hence we integrate them
into the solution as well:
SET UCORRMALGOSWITCH:ReservedSwitch0=RESERVED_SWITCH_0_BIT3-1;
SET UCORRMALGOSWITCH:ReservedSwitch0=RESERVED_SWITCH_0_BIT23-1;
SET URRCTRLSWITCH: RsvdPara1=RsvdBit1_BIT25-0;
SET UCORRMALGOSWITCH: PcSwitch=PC_HSUPA_DATA_CH_PO_ADAPTIVE_ADJ_SWITCH-1;
When transplanting the solution, we can retune the above settings to adapt the requirement and
condition of each network, and not force to strictly follow the settings listed above.
All associated parameters are summarized below
Description
Basic
Requirement
for HS
Radio
resource
allocation
Decrease
RTWP
Traffic
Balance
Assign more
resource for
HS Service to
improve HS
throughput
Maintain KPI
Parameters
SrbChlTy`pe
SrbChlTypeRrcEffectFlag
PRIORITYSERVICEFORR99NRT
PRIORITYSERVICEFORR99RT
PRIORITYSERVICEFORHSDPA
PRIORITYSERVICEFORHSUPA
EDCHRATEADJUSTSET
CQIFbCk
CQIFbCkforSHO
CONSTANTVALUE
PREAMBLERETRANSMAX
NBMLdcAlgoSwitch
UlLdrTrigThd
UlLdrRelThd
UlLdrFirstAction
ULCELLTOTALTHD
EAGCHCODENUM
ERGCHEHICHCODENUM
MAXTARGETULLOADFACTOR
DraSwitch
RetryCapability
ReservedSwitch0:RESERVED_SWITCH_0_BIT5
ReservedSwitch0:RESERVED_SWITCH_0_BIT7
ReservedSwitch0:RESERVED_SWITCH_0_BIT3
ReservedSwitch0:RESERVED_SWITCH_0_BIT23
RsvdPara1
PcSwitch
The detailed configuration of these features are documented in [3] SingleRAN Features Activation
Guideline (V900R013C00_09)(PDF)-EN, [4] SingleRAN Configuration Guideline(V900R013C00_04)(PDF)EN
Unfortunately some cells emerges high UL power congestion appears in hot spot. After compares
the parameter settings, an RNC-level parameter differs from the settings of normal functioned RNC:
BEHSUPA2MSTTIRATETHS.
After unified it (SET UFRC: BEHSUPA2MSTTIRATETHS=D1280), UL power congestion recovers to
normal case. As for the slight UL power congestion, CE congestion and Code congestion in few cells in hot
spot, we can take it for granted considers the HSPA+ throughput improves tremendously. Some other
actions can be applied to relieve the congestion issue such as adding a new micro site, decreasing the
power of PCPICH, CE expansion, etc.