Professional Documents
Culture Documents
Most Common Plans and Sealing Systems API 682
Most Common Plans and Sealing Systems API 682
Process side
Seal chamber cooling
or heating and neck
bush are necessary,
unless otherwise
specified. Dead
end seal chamber
with no circulation.
Plugged connections
for possible future
circulation and
quench.
Plan 02
Between seals
Used where the
pumped product is
harmful / hazardous
and / or buffer fluid
may not contaminate
the product. External
reservoir at pressure
below seal chamber
pressure providing
buffer liquid forced
circulation.
Applicable with
hydrocarbons,
normally used in
conjunction with
plan 75 or plan 76.
Externally supplied
gas buffer (pressure
lower than seal
pressure). Buffer gas
used to dilute seal
leakage.
Plan 52
Plan 72
Plan 11
Plan 53A
Used in applications
where the product is
harmful/hazardous.
Externally supplied
barrier gas used to
positively prevent
process fluid
from leaking to
atmosphere.
A N2
Plan 13
A connect to plan 75
For general
applications. Product
pumped clean, good
lubricating properties
and heat removal
from the mechanical
seal. Recirculation
from pump discharge
through flow control
orifice to the seal.
B connect to plan 76
C N2
Plan 74
A N2
Plan 53B
Application
when pump fluid
condenses at ambient
temperatures.
Containment seal
chamber drain for
condensing leakage.
to flare
Plan 75
*
A
to drain
Used in applications
with suspended
solids where the SG
of the particles are
2x that of the liquid.
Recirculation from
pump discharge
through a cyclone
separator, clean fluid
to seal chamber,
contaminated fluid to
suction.
Plan 21 (22)
Plan 23
Used in harmful/
hazardous
applications.
Pressurized clean
barrier fluid from
an external system.
Fluid circulation by
an external pump or
pressure system.
Application where
pump fluid does
not condense at
ambient temperature.
Containment seal
chamber drain for
non-condensing
leakage.
Plan 53C
Used to keep
atmospheric side of
seal clean. External
source providing a
flow-through quench
to atmospheric side.
to flare
Plan 54
Media characteristics
Suspended solids
Poor lubrication
High temperature
Hazardous / harmful
Leakage may form solids
Close to vapourisation point
Atmospheric side
Plan 31
Plan 76
Plan 62
Plan 32
Plan 65
A
to drain
1cw-fx H75VN
API 682
Seal Classification
Category
Examples
Category 1
Category 2
Category 3
1cw-fx MFL85N
Contacting Wet - FiXed throttle bushing
Burgmann H75VN (Type A)
1CW-FX
1CW-FX
Configurations
Arrangement 1
1CW-FX
2cw-cw H75VK-PTA
Arrangements
1CW-FL
Contacting Wet - FLoating throttle bushing
Arrangement 2
2CW-CW
1c
Contacting Wet Contacting Wet
Burgmann H75VK-H75P (Type A)
2CW-CW
F
2NC-CS
LBO
Werb-Nr.
2841
Q
LBI
2nc-cs CGS
2cw-cs
H75VK+CGSH
Werb-Nr.
2788
Arrangement 3
1CW-FL
3CW-BB
Contacting Wet - Back-to-Back
3CW-FF
Contacting Wet - Face-to-Face
3NC-BB
2CW-CS
Non-Contacting - Back-to-Back
3NC-FF
CSV CSD
GBI
2NC-CS
Werb-Nr. 2790
Non-Contacting Containment-Seal
Burgmann CGSH-CGSH (Type A)
CSV CSD
GBI
Non-Contacting - Face-to-Face
Werb-N
3NC-FB
3cw-bb H75
Non-Contacting - Face-to-Back
Types
Type A
Pusher seal
Temperature: -40 176 C (-40 350 F), pressure: 41 bar g (600 PSI)
Type B
Metal bellows seal with O-rings
Temperature: -40 176 C (-40 350 F), pressure: 21 bar g (300 PSI)
3CW-FB
F
Type C
Metal bellows seal with flexible graphite
Temperature: -40 400 C (-40 750 F), pressure: 21 bar g (300 PSI)
LBI
3CW-BB
LBO
Werb-Nr. 2789
LBI
3nc-fb HR
3nc-bb CGSH-KD
Type ES
Werb-Nr. 2791
Totally Engineered Sealing system for service conditions outside the operating limits of type A, B and C
Arrangement
A3
Type
A
API plan(s)
1153A
Category 1 = C1
Category 2 = C2
Category 3 = C3
3NC-BB
Arrangement 1 = A1
Arrangement 2 = A2
Arrangement 3 = A3
Non-Contacting Back-to-Back
Burgmann CGSH-KD (Type A)
3NC-FB
GBI
Non-Contacting Face-to-Back
Burgmann HRGS-DD (Type A)
GBI
Werb-Nr. 2792
Type A = A
Type B = B
Type C = C
API plans: 02, 11, 13, 21(22), 23, 31, 32, 52, 53A, 53B, 53C, 54, 62, 65, 72, 74, 75, 76
Explanation
of example
C2A3A1153A
Werb-Nr. 2846
Default configurations
Optional configurations
Werb-Nr.
Example