Wind Load Analysis for 10-Story Building

This document provides an analysis of the wind loads and frame forces on a 10-story residential building located in Panchlaish, Chittagong, Bangladesh. It includes input data such as the wind velocity, height and width of each floor, and number of stories. The wind pressure is calculated to be 2.78 kN at the 10th floor and 0.03 kN at the 1st floor. A portal frame analysis method is used to calculate the horizontal forces at each joint, with the maximum force of 57.34 kN and minimum of -28.71 kN.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
136 views1 page

Wind Load Analysis for 10-Story Building

This document provides an analysis of the wind loads and frame forces on a 10-story residential building located in Panchlaish, Chittagong, Bangladesh. It includes input data such as the wind velocity, height and width of each floor, and number of stories. The wind pressure is calculated to be 2.78 kN at the 10th floor and 0.03 kN at the 1st floor. A portal frame analysis method is used to calculate the horizontal forces at each joint, with the maximum force of 57.34 kN and minimum of -28.71 kN.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

Name of Project: 10-Storied Residential Building

Name of Client: Md. Musa & Gang.


Panchlaish, CTG.

Designed By: Engr. Sudhir Kumar Sharama


harma
ESEC Ltd. Dhaka, 0171932006

FRAME ANALYSIS DUE TO HORIZONTAL LOAD (WIND PRESSURE):10STORIED


1-BAY

INTERIOR BAY

INPUT DATA:
1 Wind Velocity,v

120 mph

2 Height of Floor,h

10 ft

3 width of floor,l

6 ft

4 No. of story,n

10 no.

Wind load pressure,p

2
2/7
= 0.0025V (H/30)

(Ref.page-67, Bungle S.Taranath,SA&DTB)

1.71 k

10 ft

2.78 k

10 ft

2.19 k

10 ft

1.68 k

10 ft

1.23 k

10 ft

0.86 k

10 ft

0.55 k

10 ft

0.31 k

10 ft

0.14 k

10 ft

0.03 k

10 ft
10.42

WIND PRESSURE DISTRIBUTION ON FRAME


FRAME ANALYSIS BY USING PORTAL METHOD:
4.29

4.29
0.82

1.71 -4.29

-4.29

0.86

0.86

-4.29 15.51
2.98

2.78 -11.23

-11.23

2.25

2.25

-11.23 27.94

-16.71

3.34

3.34

-16.71 37.63

-20.91

4.18

4.18

-20.91 44.91

-24.00

4.80

4.80

-24.00 50.14

-26.14

5.23

5.23

-26.14 53.66

-27.51

5.50

5.50

-27.51 55.80

-28.29

5.66

5.66

-28.29 56.91

-28.63

5.73

5.73

-28.63 57.34

-28.71

5.74

5.74

-28.71

-28.71
5.21

10 ft

57.34
11.01

0.03 -28.71

10 ft

56.91
10.92

0.14 -28.63

10 ft

55.80
10.71

0.31 -28.29

10 ft

53.66
10.30

0.55 -27.51

10 ft

50.14
9.62

0.86 -26.14

10 ft

44.91
8.62

1.23 -24.00

10 ft

37.63
7.22

1.68 -20.91

10 ft

27.94
5.36

2.19 -16.71

10 ft

15.51

5.21

10 ft