Professional Documents
Culture Documents
SERIES Z
www.MitsubishiElectric.com/elevator
with architecture
Brings elegance and sophistication to your building
flexibility to blend with any building decor. Our years of to select from
Enables customization for uniqueness
experience in safety-oriented production, based on a
strong belief in the importance of safety, have led to a
Automatic Operation / 11
variety of safety features, as well as a wide range of Variable-Speed Operation
value-added functions that help you customize your own
escalators, creating uniqueness in and incomparable Standard specifications 12
GLASS
PANEL ZS
Lighting under the Moving
Handrails creates an effect
of warm, glowing elegance.
STAINLESS
PANEL ZP
Dimensions
Rise
30° : max 7000mm*1
35° : max 6000mm
Step width
Type S600 : 604mm
Type S800 : 804mm
Type S1000: 1004mm Inclination Stainless steel panel that
30° or 35° exudes strength and durability.
*1: Please refer to the enclosed leaflet for rises exceeding 7000mm.
Z
*2: Please contact your local Mitsubishi Electric sales agent for 1000mm-high Moving Handrails.
ESCALATOR
Escalators in the graphics are based on the Japan Code, with SERIES
optional Fluoropolymer Coating on Skirt Guard.
3 4
Moving
Handrail
Colors available for Moving Handrails (rubber) Only "No. 0001 Black" is standard. Other colors are optional.
Floor Plate
Handrail colors for outdoor use are different from these shown on this page. Please contact your local Mitsubishi Electric sales agent for details.
Handrail colors shown in photos may differ slightly from the actual colors on products.
Escalators in the graphics are based on the Japan Code, with
optional Fluoropolymer Coating on Skirt Guard.
ESCALATOR
SERIES Z
5 6
Step
Lighting*1
Inlet Sensor
Warning System*3
Outer Deck Sensor*4 Inlet Sensor Handrail Inlet Cap
Floor Name LED Indicator
When a sensor on the Outer This sensor keeps any passengers
Deck detects a passenger leaning or foreign objects away from the
outside the Moving Handrail, a Handrail Inlet, a warning buzzer and
buzzer and voice sound to alert voice sounding when a person or *1: For available combinations of optional features, please refer to the Specifications on the enclosed leaflet.
the passenger to the potential object comes close to the Inlet. *2: Not applicable to semi-outdoor and outdoor use.
danger of bumping against an *3: Not applicable to outdoor use.
*4: Not applicable to model ZP.
adjacent escalator or wall. *5: Standard feature in countries where EN115 applies.
More Options Polyurethane Moving Handrail Available as an option, Moving Handrails made of polyurethane are
highly resistant to dirt on their surface and create a shiny, brighter look.
Floor Name Fluoropolymer Coating on Colors available for polyurethane Moving Handrails
Handrail colors shown in photos may differ slightly from the actual colors on products.
ESCALATOR
SERIES Z
9 10
A utomatic Operation
O / V ariable-Speed Operation PTIONAL S tandard specifications
Inverter-controlled Automatic and Variable-Speed Operations Basic Please refer to the enclosed leaflet for EN115 code or Japan code.
specifications
Item S600 S800 S1000
VVVF Control (Variable Voltage, Variable Frequency) Models ZS / ZL / ZP
Codes EN115 *1 code / Japan code
Our newly-developed, innovative escalator inverter enables a unique way of controlling the Power supply AC 3-phase, 50 or 60Hz
escalator speed in Automatic and Variable-Speed Operations. In Variable-Speed Operation, the Lighting power supply AC single-phase, 50 or 60Hz
Rated speed 0.5m/sec
escalator speed can be selected according to the frequency of use, number of passengers, and Standard: AC1 Option: VVVF *2
Control system
more. Please contact your local Mitsubishi Electric sales agent for VVVF control. Theoretical transport capacity *3 (persons/hr) 4500 6750 9000
Inclination 30° / 35°
Post-Free Automatic Operation Environment Standard: Indoor Option *4 : Semi-outdoor / Outdoor
Automatic oiler Standard: None Option: Available
Sensor Posts are no longer needed, as the sensors Min. rise (mm) 30°: 2203 35°: 2527
embedded in the Handrail Inlet Cap detect passengers Max. rise (mm) 30°: 7000 *5 35°: 6000
and control Automatic Operation. The escalator Step width (mm) 604 804 1004
operates at a low speed in stand-by, and gradually Escalator width (mm) 1150 1350 1550
increases speed to the rated speed after detecting a
Between Moving Handrails (mm) 840 1040 1240
passenger approaching the boarding area.
Between Skirt Guards (mm) 610 810 1010
Truss width (mm) 1100 1300 1500
Escalators operate at a low speed in stand-by. Floor opening (mm) 1250 1450 1650
*1: The specifications differ depending on the publication year of the code. Please contact your local Mitsubishi Electric
Landing Rated speed sales agent for details.
(in operation)
Boarding *2: Please contact your local Mitsubishi Electric sales agent for VVVF control.
Handrail Inlet Cap LED Indicator*1
Speed
*3: Transport capacity varies depending on actual traffic conditions, so some dimensions and the motor capacity may have
Low speed
to be changed. Please contact your local Mitsubishi Electric sales agent for details if the number of passengers during
(in stand-by)
peak time may equal or exceed the following numbers:
0m/sec S600: 525 persons per 10 minutes
(Stop) S800: 785 persons or more per 10 minutes
Detection of passengers Time S1000: 1050 persons per 10 minutes
Boarding area Landing area *4: Please contact your local Mitsubishi Electric sales agent for semi-outdoor and outdoor use. For outdoor use, please
refer to “Cautions for outdoor use” on page 13.
*1: Handrail Inlet Cap LED Indicator:
- Remains the same regardless of the operating speed during Automatic Operation. *5: Please refer to the enclosed leaflet for rises exceeding 7000mm.
- A separate option, and not included in Post-Free Automatic Operation.
Control by AC1, instead of inverter control, can be adopted Deck Board Deck Board
Stainless steel
hairline
Interior Panel Interior Panel Interior Panel
in Automatic Operation with Posts, whereby the escalator (Outer Deck)
Stainless steel
Transparent
(Outer Deck)
Stainless steel
Transparent Stainless steel
tempered glass tempered glass
remains stationary on stand-by. hairline hairline
hairline
Deck Board
(Inner Deck) Deck Board Deck Board
(Inner Deck) (Inner Deck)
Stainless steel
Stainless steel
*2: For escalators stationary in stand-by, Directional Indicators are hairline
hairline
Stainless steel
hairline
required in countries where EN115 applies.
Variable-Speed Operation
ZS ZL ZP
Two more speeds*3, not exceeding the rated speed, can be added
to your escalator to make it possible to operate at three different
speeds. The speeds are selected using a key switch, set at Low or
Middle for the added speeds and High for the rated speed, thereby
allowing you to select the best speed for each set of traffic
conditions.
*3: For an escalator with a rated speed of 0.6m/sec, for example, additional speeds of 0.5m/sec and 0.3m/sec
can be set. For more information, contact your local Mitsubishi Electric sales agent.
ESCALATOR
SERIES Z
11 12
Cautions for outdoor use / Remote monitoring
Cautions for outdoor use
A roof must be provided over outdoor escalators. In rainy weather without a roof, passengers are in great danger of having their umbrellas
blown away by the wind or falling down on the slippery Steps. In hot weather, the Moving Handrails and Deck Boards can easily heat up
LQWKHVXQWRDVXUIDFHWHPSHUDWXUHH[FHHGLQJ&FDXVLQJWKHXQQHFHVVDU\FKDQFHWKDWSDVVHQJHUVFRXOGJHWEXUQWRQWKH
overheated elements. In addition, when not covered by a roof, the life and performance of outdoor escalators seriously deteriorate,
leading to shorter product life and higher cost for maintenance.
IMPORTANT INFORMATION
1. How to define outdoor escalators
Escalators are classified into three categories: outdoor, semi-outdoor and indoor. Outdoor escalators are defined as escalators exposed
to environmental factors such as wind, rain, snow or direct sunlight.
*1: Please note that MelEye is designed for monitoring of escalator operation, not to control the escalators remotely.
*2: Contact your local Mitsubishi Electric sales agent for a brochure or further information.
ESCALATORS
SERIES Z
www.MitsubishiElectric.com/elevator
j4 L - 1 7 0 - 6 - C79 3 9 0 -G j1
L ayout For Japan Code
Floor opening
Floor opening
Comb Comb
Comb Comb
W1+100
W1+100
765 1035
NK-865 NJ-865
RC, SRC structure Min. 270 RC, SRC structure Min. 270
120±10
120±10
Steel structure Min. 250 Steel structure Min. 250
Finished floor level Finished floor level
Lower floor opening Wiring inlet (R.H.) Lower floor opening Wiring inlet (R.H.)
Max. LF Max. UF Max.LF Max.UF
Upper floor opening Upper floor opening
LL=TG+250
+40 LL=TG+250
75 Distance between support beams MM 0 75
Anchor Anchor +40
+30
Truss length TG
+30 75 Distance between support beams MM 0 75
50 0 50 0 Support beam end
Support beam end +30 +30
50 0 Truss length TG 50 0
Truss end TK HE/tan30° TJ Truss end
TK=2260 HE/tan35° TJ=2530
Support beam section detail (by owner) Support beam section detail (by owner)
LA Max. 11000 for S1000, S800 LB Max.11000 for S1000, S800
Max. 11700 for S600 Max.11700 for S600 Clearance LA Max. 11000 for S1000, S800 LB Max. 11000 for S1000, S800
W1 NJ Min.2000 W1 Max. 11700 for S600
Safety fence Max. 11700 for S600 Clearance
Safety fence NJ
W2 (by owner) W2 Min. 2000
(by owner)
W3
W3
950
950
R2100 R2100
RB
250
250
RB
F.L. F.L. F.L. F.L.
Wedge guard W.P.
(by owner) Wedge guard W.P.
1030
NJ-385 (by owner) 1515
1030
79
440 440 440
20 440
0
215
79
Recommended Recommended Ceiling
0
Min. 2120
Ceiling
Overhead
91
HE Rise
Max. 7000
Overhead
Min. 2140
2390
Max. 6000
5
HE Rise
91 Wiring inlet (R.H.)
R1500
5 TJ-140
R1500 50
Truss
Truss
Outer sheathing
panel (by owner) Outer sheathing
950
RC RC
30°
950
RA
35°
RA
SA
F.L.
F.L.
SA
W.P. Intermediate support beam is Intermediate support beam is
required when TG exceeds W.P. required when TG exceeds
1030
Floor opening
1100
15000mm for Type S1000 Floor opening 15000mm for Type S1000
1030
1100
NK-385 Min. 2000 Height of intermediate 15500mm for Type S800 or 1245 Min. 1800 15500mm for Type S800 or
support beams,180~1000. 16000mm for Type S600 Height of intermediate 16000mm for Type S600
support beams,180~1000.
For VVVF control, TJ may increase from that shown. Please contact For VVVF control, TJ may increase from that shown. Please contact
your local Mitsubishi Electric sales agent for details. your local Mitsubishi Electric sales agent for details.
■Standard dimensions ■Reaction force on beam (N) ■Standard dimensions ■Reaction force on beam (N)
Type S600 S800 S1000 Without intermediate support beam With intermediate support beam Type S600 S800 S1000 Without intermediate support beam With intermediate support beam
W1 (Escalator Width) 1150 1350 1550 W1 (Escalator Width) 1150 1350 1550
4220・(LL-TK+X1)+12000・(TJ-X2) 4220・(TK-X1) 4220・(TK-1111)
W2 (Between Moving Handrails) 840 1040 1240 RA α・LL+
LL
α・LA+4220-
LA W2 (Between Moving Handrails) 840 1040 1240 RA α・LL+ 4220・(LL-TK+1111)+12000・(TJ-1370) α・LA+4220-
LL LA
W3 (Between Skirt Panels) 610 810 1010 W3 (Between Skirt Panels) 610 810 1010
α・LL+ 4220・(TK-X1)+12000・(LL-TJ+X2) α・LB+12000- 12000・(TJ-X2)
RB
LL LB
RB α・LL+ 4220・(TK-1111)+12000・(LL-TJ+1370) α・LB+12000- 12000・(TJ-1370)
Horizontal Steps LF UF NK NJ Horizontal Steps LF UF NK NJ LL LB
1.5 Steps(Nominal)* 850 1100 1385 1635 2 Steps 1095 1365 1630 1900
RC α・LL+
4220・(TK-X1)
+
12000・(TJ-X2)
RC α・LL+ 4220・(TK-1111) + 12000・(TJ-1370)
3 Steps 1440 1725 1975 2260 LA LB LA LB
Type TG Environment 1.5 Steps(Nominal)* 2265 2015 866 1105 Type TG Environment
Indoor 3 Steps 2890 2605 1456 1730 Indoor
Semi-outdoor Outdoor Semi-outdoor Outdoor
TG 13500 4.04 TG 13500 4.04
S1000 13500<TG 15000 4.11 4.04 S1000 13500<TG 15000 4.11 4.04
15000<TG 4.04 15000<TG 4.04
TG 13850 3.60 TG 13600 3.60
S800 13850<TG 15500 3.66 S800 13600<TG 15250 3.66
15500<TG 3.60 15250<TG 3.60
TG 14200 3.16 TG 14200 3.16
S600 14200<TG 16000 3.22 3.16 S600 14200<TG 16000 3.22 3.16
16000<TG 3.16 16000<TG 3.16
*Please contact your local Mitsubishi Electric sales agent for the
actual number of steps.
j2 j3
S afety devices S pecifications
The Series Z escalator is equipped with
various safety devices that provide for
safety and reliability. For EN115 Code For EN115 Code
Max rise (mm): 7000 (30°), 6000 (35°)
●…Standard ○…Optional N/A…Not applicable
●…Standard ○…Optional
Division Specification
ZS ZL ZP
○ Step Motion Safety Device (CRS) ● Emergency Stop Button (E-STOP)
Indoor ●
A safety device to stop the escalator when a Step has been A button to immediately stop the escalator in emergency Environment Semi-outdoor *1
dislocated on its riser side due to an object caught between situations. Outdoor *1*1 N/A
the Steps, or between the Skirt Guard and the Step, or if an
AC1 ●
abnormality has been observed in the Step motion. ●* Door Open Switch (DOS) Inverter (VVVF) ○ *2
Control
A safety switch that stops the escalator when the manhole Automatic Operation with Posts (Stationary in stand-by, AC1) ○
system
cover is opened. Automatic Operation with Posts (Slow operation in stand-by, Inverter) ○
* - EN115-1: 2008 + A1: 2010 → Standard
Post-Free Automatic Operation (Slow operation in stand-by, Inverter) ○
- EN115-1/A2: 2004 → Not applicable Stop-Buzzer Key Switch ●
Anti-Slip Floor Plate ●
● Overload Detection Device Step with Anti-Slip Grooves ●
Demarcation Line ●
A safety device that stops the escalator if overload has
been detected by abnormal current or temperature of the
Tiered Demarcation Line ●
drive motor. Safety Step Demarcation Lighting ○
features Comb Light ○
● Drive Chain Safety Device (DCS) Three Horizontal Steps ○/● *3
Warning System on Moving Handrail Inlet (Inlet Sensor) ○ *4
A safety device that stops the escalator if the Drive Chain
Warning System on Outer Deck (Outer Deck Sensor) ○ *4 N/A
breaks or stretches beyond an allowable limit.
Directional Indicator on Handrail Inlet Cap (Handrail Inlet Cap LED Indicator) ○*4 *5
Transparent tempered glass panel ● N/A
● Speed Governor (GOV) Balustrade
(See page 12 for Under-Handrail Lighting N/A ● N/A
A safety device that stops the escalator if the speed sections.) Stainless steel hairline panel N/A ●
significantly decreases or increases to 120% of the rated
Skirt Guard Fluoropolymer Coating ●
speed.
Skirt Guard Lighting ○*6 N/A ○*6
○* Auxiliary brake ● Electromagnetic Brake Deck Board Stainless steel hairline ●
Step Aluminum alloy Step Tread ●
A safety device that stops the escalator if the speed A safety device that stops the escalator in the case of Finish and Aluminum alloy Cleat Riser ●
exceeds the rated speed, or before the Steps’ power failure, or if any safety device or the Emergency
decorative Yellow Demarcation Line ●
traveling direction changes due to an abnormality Stop Button has been activated.
such as breakage of the Drive Chain. components Floor Plate Decorative Panel (Embossed stainless steel) ●
Floor Name ○
* A standard device for public-use escalators or those
exceeding 6m in rise. Comb ●
Extension of Floor Plate ○
Connection of adjacent Floor Plates ○
Moving Handrail Rubber No. 0001 (Black) ●
● Step Level Device (SRS) ●* Handrail Speed Safety Device (HSS) No. 0502 to 0508 (See page 5 for colors.) ○
A safety device that stops the escalator if the horizontal A safety device that stops the escalator if the Moving Polyurethan No. 5001 to 5010 (See page 10 for colors.) ○
level of a Step has dropped. Handrails fail to synchronize with the Steps due to Handrail Inlet Cap Plastic ●
slippage, loosening or breakage of the Moving Handrails. MelEye ○
Others
○ Skirt Guard Safety Device (SSS) * - EN115-1: 2008 + A1: 2010 → Standard
Automatic oiler ○
- EN115-1/A2: 2004 → Optional *1: Please contact your local Mitsubishi Electric sales agent for semi-outdoor and outdoor use.
A safety device to stop the escalator if a shoe or other
item becomes trapped in the gap between the Step and *2: Please contact your local Mitsubishi Electric sales agent for VVVF control.
*3: A standard feature for rises exceeding 6000mm or rated speeds exceeding 0.5m/sec.
Skirt Guard.
*4: Not applicable to outdoor use.
*5: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas).
● Comb-Step Safety Switch (CSS) *6: Not applicable to semi-outdoor and outdoor use.
A safety device that stops the escalator if a foreign object Deck Board
becomes trapped in the gap between the Step and Comb. Moving Handrail
e4 L - 1 7 0 - 6 - C 7 9 4 0 0 -G e1
L ayout For EN115 Code
EN 30° EN 35°
Manhole cover
(Unit: mm) Manhole cover Manhole cover (Unit: mm) Manhole cover
Floor opening
Floor opening
Comb Comb Comb Comb
W1+100
W1+100
NK-865 NJ-865 765 1035
RC, SRC structure Min. 270 RC, SRC structure Min. 270
120±10
120±10
Steel structure Min. 250 Steel structure Min. 250
Finished floor level Finished floor level
Lower floor opening Wiring inlet (R.H.) Max. LF Lower floor opening Wiring inlet (R.H.)
Max. LF Upper floor opening Max. UF Max.UF
Upper floor opening
LL=TG+250
+40
75 LL=TG+250
75 Distance between support beams MM 0
Anchor Anchor +40
+30 +30 75
50 0 Truss length TG 50 0 75 Distance between support beams MM 0
Support beam end Support beam end
+30 +30
Truss end Truss end 50 0 Truss length TG 50 0
TK HE/tan30° TJ
TK=2260 HE/tan35° TJ=2530 (S1000, S800)
Support beam section detail (by owner) Support beam section detail (by owner) TJ=3080 (S600)
LA Max. 11000 for S1000, S800 LB Max.11000 for S1000, S800
Max. 11700 for S600 Max.11700 for S600 Clearance LA Max. 11000 for S1000, S800 LB Max. 11000 for S1000, S800
W1 NJ Min.2000 W1
Safety fence Max. 11700 for S600 Max. 11700 for S600 Clearance
(by owner) Safety fence
W2 NJ Min.2000
W2 (by owner)
W3
950
W3
950
R2100 RB R2100
250
RB
250
F.L. F.L.
F.L. F.L.
Wedge guard W.P.
Wedge guard W.P.
1030
(by owner) NJ-385 (by owner) 1515
1030
79
440 440
20 440 440
0
79
Ceiling 215
Recommended Recommended
0
Ceiling
Min. 2320
Overhead
Clearance Recommended
Wiring inlet (R.H.) Recommended Clearance
Min. 2000 NK
HE Rise
91
Max. 7000
Min. 2340
Overhead
NK 2390 (S1000,S800)
5
Max. 6000
HE Rise
91 Wiring inlet (R.H.)
5 Truss TJ-140 R1500 2940 (S600)
R1500
50
950
RC
RA
35°
F.L.
SA
F.L.
SA
Intermediate support beam is W.P. Intermediate support beam is
W.P.
required when TG exceeds required when TG exceeds
Floor opening
1030
1100
15000mm for Type S1000 Floor opening 15000mm for Type S1000
1030
1100
NK-385 Min. 2000 Height of intermediate
15500mm for Type S800 or 1245 Min. 1800 15500mm for Type S800 or
support beams,180~1000. Height of intermediate
16000mm for Type S600 16000mm for Type S600
support beams,180~1000.
For VVVF control, TJ may increase from that shown. Please contact For VVVF control, TJ may increase from that shown. Please contact
your local Mitsubishi Electric sales agent for details. your local Mitsubishi Electric sales agent for details.
■Standard dimensions ■Reaction force on beam (N) ■Standard dimensions ■Reaction force on beam (N)
Type S600 S800 S1000 Without intermediate support beam With intermediate support beam Type S600 S800 S1000 Without intermediate support beam With intermediate support beam
W1 (Escalator Width) 1150 1350 1550 W1 (Escalator Width) 1150 1350 1550
4220・(TK-X1)
W2 (Between Moving Handrails) 840 1040 1240
RA α・LL+ 4220・(LL-TK+X1)+12000・(TJ-X2) α・LA+4220-
W2 (Between Moving Handrails) 840 1040 1240
RA α・LL+ 4220・(LL-TK+1111)+12000・(TJ-1370) α・LA+4220- 4220・(TK-1111)
LL LA LL LA
W3 (Between Skirt Panels) 610 810 1010 W3 (Between Skirt Panels) 610 810 1010
RB α・LL+ 4220・(TK-X1)+12000・(LL-TJ+X2) α・LB+12000- 12000・(TJ-X2) RB α・LL+ 4220・(TK-1111)+12000・(LL-TJ+1370) α・LB+12000- 12000・(TJ-1370)
Horizontal Steps LF UF NK NJ LL LB Horizontal Steps LF UF NK NJ LL LB
2 Steps 850 1100 1550 1835 2 Steps 1095 1365 1630 1900
RC α・LL+ 4220・(TK-X1) +
12000・(TJ-X2)
RC α・LL+ 4220・(TK-1111) + 12000・(TJ-1370)
3 Steps 1440 1725 1975 2260 LA LB LA LB
e2 e3
For High Rise
Safety devices
The Series Z escalator is equipped with
For Japan Code
various safety devices that provide for
safety and reliability. For Japan Code
Floor opening
system Automatic Operation with Posts (Slow operation in stand-by, Inverter) ○
RC, SRC structure Min. 270
120±10
Steel structure Min. 250 Comb Comb
W1+100
○
Finished floor level
Post-Free Automatic Operation (Slow operation in stand-by, Inverter)
NK-865 NJ-865
Stop-Buzzer Key Switch ●
Anti-Slip Floor Plate ●
Step with Anti-Slip Grooves ● Anchor
Lower floor opening Wiring inlet (R.H.)
Max. LF Max. UF
●
Support beam end Upper floor opening
Demarcation Line
Truss end
Tiered Demarcation Line ●
Support beam section detail (by owner)
Safety Step Demarcation Lighting ○
features Comb Light ○
Three Horizontal Steps ○
Warning System on Moving Handrail Inlet (Inlet Sensor) ○ *2
Warning System on Outer Deck (Outer Deck Sensor) ○ *2 N/A
Directional Indicator on Handrail Inlet Cap (Handrail Inlet Cap LED Indicator) ○ *2 *3 75 Distance between support beams MM
LL=TG+250
+40
75
0
Balustrade Transparent tempered glass panel ● N/A 50
+30
Truss length TG 50
+30
0
0
(See page 12 for Under-Handrail Lighting N/A ● N/A
TK HE/tan30° TJ
sections.) Stainless steel hairline panel N/A ●
●
LA Max. 11000 for S1000 LB Max. 11000 for S1000
Skirt Guard Stainless steel hairline Max. 11700 for S600 Max. 11700 for S600 Clearance
Fluoropolymer Coating ○ W1
Safety fence
NJ Min.2000
950
R2100
Finish and Step Aluminum alloy Step Tread ● RB
250
Aluminum alloy Cleat Riser ● F.L. F.L.
decorative Wedge guard W.P.
Yellow Demarcation Line ● (by owner)
components
1030
NJ-385
Floor Plate Decorative Panel (Embossed stainless steel) ● 440 440
20
79
Ceiling
Max. ZS / ZP : 13000
○
0
Recommended
Floor Name Recommended
ZL : 9000
Min. 2120
Overhead
Clearance
Min. 2000 NK Wiring inlet (R.H.)
●
HE Rise
Comb 125
91
TJ-140
Extension of Floor Plate ○
5
R1500
Truss
Connection of adjacent Floor Plates ○
Moving Handrail Rubber No. 0001 (Black) ● Outer sheathing
panel (by owner)
○
950
No. 0502 to 0508 (See page 5 for colors.) RC
30°
RA
SA
F.L.
Polyurethan No. 5001 to 5010 (See page 10 for colors.) ○ W.P. Intermediate support beam is
●
required when TG exceeds
Handrail Inlet Cap Plastic Floor opening
1030
1100
13250mm for Type S1000
NK-385 Min. 2000 Height of intermediate
MelEye ○
13900mm for Type S600
support beams,180~1000.
Others
Automatic oiler ○
*1: Please contact your local Mitsubishi Electric sales agent for VVVF control.
*2: Not applicable to outdoor use.
*3: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas).
*4: Not applicable to semi-outdoor and outdoor use.
*Please contact your local Mitsubishi Electric sales agent for the
actual number of steps.
Escalators in the graphics are based on the Japan Code, with optional
Fluoropolymer Coating on Skirt Guard.
jh2 jh3
For High Rise
Safety devices
The Series Z escalator is equipped with
For EN115 Code
various safety devices that provide for
safety and reliability. For EN115 Code
Floor opening
Comb
○
Comb
Automatic Operation with Posts (Slow operation in stand-by, Inverter)
W1+100
Post-Free Automatic Operation (Slow operation in stand-by, Inverter) ○ NK-865 NJ-865
120±10
Steel structure Min. 250
Anti-Slip Floor Plate ● Finished floor level
○
Truss end
features Comb Light
Support beam section detail (by owner)
Three Horizontal Steps ●
Warning System on Moving Handrail Inlet (Inlet Sensor) ○ *2
○ *2
LL=TG+250
Warning System on Outer Deck (Outer Deck Sensor) N/A 75 Distance between support beams MM
+40
0 75
Directional Indicator on Handrail Inlet Cap (Handrail Inlet Cap LED Indicator) ○*2 *3 50
+30
0 Truss length TG 50
+30
0
950
R2100
●
RB
Step Aluminum alloy Step Tread
250
F.L. F.L.
Finish and Aluminum alloy Cleat Riser ● Wedge guard W.P.
decorative ●
1030
Yellow Demarcation Line (by owner) NJ-385
440 440
components Floor Plate Decorative Panel (Embossed stainless steel) ● 20
79
Max. ZS / ZP : 13000
Recommended Recommended Ceiling
0
ZL : 9000
Overhead
Min. 2320
Clearance
Floor Name ○ Min. 2000 NK Wiring inlet (R.H.)
HE Rise
125
Comb ●
91
Truss TJ-140
5
○
R1500
Extension of Floor Plate
Connection of adjacent Floor Plates ○ Outer sheathing
panel (by owner)
Moving Handrail Rubber No. 0001 (Black) ●
950
RA RC
30°
No. 0502 to 0508 (See page 5 for colors.) ○ F.L.
SA
○
Intermediate support beam is
Polyurethan No. 5001 to 5010 (See page 10 for colors.) W.P.
required when TG exceeds
Floor opening
1030
1100
Handrail Inlet Cap Plastic ● NK-385 Min. 2000 Height of intermediate 13250mm for Type S1000
13900mm for Type S600
support beams,180~1000.
MelEye ○
Others
Automatic oiler ○
*1: Please contact your local Mitsubishi Electric sales agent for VVVF control.
*2: Not applicable to outdoor use.
*3: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas).
*4: Not applicable to semi-outdoor and outdoor use.
Balustrade Please contact your local Mitsubishi Electric sales agent for:
- VVVF control (Please note that TJ may increase from that shown.)
- Reaction force, RA, RB, RC etc.
Skirt Guard Step
■Standard dimensions
Type S600 S1000
W1 (Escalator Width) 1150 1550
W2 (Between Moving Handrails) 840 1240
Floor Plate W3 (Between Skirt Guards) 610 1010
Horizontal Steps LF UF NK NJ
Operating Panel
3 Steps 1440 1725 1975 2260
Escalators in the graphics are based on the Japan Code, with optional
Fluoropolymer Coating on Skirt Guard.
eh2 eh3