Professional Documents
Culture Documents
with architecture
Brings elegance and sophistication to your building
flexibility to blend with any building decor. Our years of to select from
Enables customization for uniqueness
experience in safety-oriented production, based on a
strong belief in the importance of safety, have led to a
Automatic Operation / 11
variety of safety features, as well as a wide range of Variable-Speed Operation
value-added functions that help you customize your own
escalators, creating uniqueness in and incomparable Standard specifications 12
GLASS
PANEL ZS
Lighting under the Moving
Handrails creates an effect
of warm, glowing elegance.
STAINLESS
PANEL ZP
Dimensions
Rise
30° : max 7000mm*1
35° : max 6000mm
Step width
Type S600 : 604mm
Type S800 : 804mm
Type S1000: 1004mm Inclination Stainless steel panel that
30° or 35° exudes strength and durability.
*1: Please refer to the enclosed leaflet for rises exceeding 7000mm.
Z
*2: Please consult our local agents for 1000mm-high Moving Handrails.
ESCALATOR
Escalators in the graphics are based on the Japan Code, with SERIES
optional Fluoropolymer Coating on Skirt Guard.
3 4
Moving
Handrail
Colors available for Moving Handrails (rubber) Only "No. 0001 Black" is standard. Other colors are optional.
Floor Plate
Handrail colors for outdoor use are different from these shown on this page. Please consult our local agents for details.
Handrail colors shown in photos may differ slightly from the actual colors on products.
Escalators in the graphics are based on the Japan Code, with
optional Fluoropolymer Coating on Skirt Guard.
ESCALATOR
SERIES Z
5 6
Step
Warning System*3
Outer Deck Sensor*4 Inlet Sensor
When a sensor on the Outer This sensor keeps any passengers
Deck detects a passenger leaning or foreign objects away from the
outside the Moving Handrail, a Handrail Inlet, a warning buzzer and
buzzer and voice sound to alert voice sounding when a person or
the passenger to the potential object comes close to the Inlet.
danger of bumping against an
adjacent escalator or wall.
Clean Solutions
Antibacterial Polyurethane Moving Handrail*3 *6 *7 Handrail Sterilizer*6
No.9001 No.9002 No.9003 No.9004 No.9005 No.9006 No.9007 No.9008 No.9009 No.9010 The sterilizer continuously emits
Our antibacterial handrails Black Vermilion Red Yellow Green Blue Light gray Brown Mild black Warm gray
made of polyurethane UV light to remove bacteria from
suppress the growth of the handrails while the escalator
bacteria by mixing antibacterial is running.
agents into the polyurethane
layer. The handrails are highly
resistant to dirt and create a
shiny, brighter look.
Handrail colors shown in photos may differ slightly from the actual colors on products.
ESCALATOR
SERIES Z
9 10
A utomatic Operation
O / V ariable-Speed Operation PTIONAL S tandard specifications
Inverter-controlled Automatic and Variable-Speed Operations Basic Please refer to the enclosed leaflet for EN115 code or Japan code.
specifications
Item S600 S800 S1000
VVVF Control (Variable Voltage, Variable Frequency) Models ZS / ZL / ZP
Codes EN115 *1 code / Japan code
Our newly-developed, innovative escalator inverter enables a unique way of controlling the Power supply AC 3-phase, 50 or 60Hz
escalator speed in Automatic and Variable-Speed Operations. In Variable-Speed Operation, the Lighting power supply AC single-phase, 50 or 60Hz
Rated speed 0.5m/sec
escalator speed can be selected according to the frequency of use, number of passengers, and Standard: AC1 Option: VVVF *2
Control system
more. Please consult our local agents for VVVF control. Theoretical transport capacity *3 (persons/hr) 4500 6750 9000
Inclination 30° / 35°
Post-Free Automatic Operation Environment Standard: Indoor Option *4 : Semi-outdoor / Outdoor
Automatic oiler Standard: None Option: Available
Sensor Posts are no longer needed, as the sensors Min. rise (mm) 30°: 2203 35°: 2527
embedded in the Handrail Inlet Cap detect passengers Max. rise (mm) 30°: 7000 *5 35°: 6000
and control Automatic Operation. The escalator Step width (mm) 604 804 1004
operates at a low speed in stand-by, and gradually Escalator width (mm) 1150 1350 1550
increases speed to the rated speed after detecting a
Between Moving Handrails (mm) 840 1040 1240
passenger approaching the boarding area.
Between Skirt Guards (mm) 610 810 1010
Truss width (mm) 1100 1300 1500
Escalators operate at a low speed in stand-by. Floor opening (mm) 1250 1450 1650
*1: The specifications differ depending on the publication year of the code. Please consult our local agents for details.
Landing Rated speed *2: Please consult our local agents for VVVF control.
(in operation)
Boarding *3: Transport capacity varies depending on actual traffic conditions, so some dimensions and the motor capacity may have
Handrail Inlet Cap LED Indicator*1
Speed
to be changed. Please consult our local agents for details if the number of passengers during peak time may equal or
Low speed
exceed the following numbers:
(in stand-by)
S600: 525 persons per 10 minutes
0m/sec S800: 785 persons or more per 10 minutes
(Stop) S1000: 1050 persons per 10 minutes
Detection of passengers Time *4: Please consult our local agents for semi-outdoor and outdoor use. For outdoor use, please refer to “Cautions for
Boarding area Landing area outdoor use” on page 13.
Variable-Speed Operation
ZS ZL ZP
Two more speeds*3, not exceeding the rated speed, can be added
to your escalator to make it possible to operate at three different
speeds. The speeds are selected using a key switch, set at Low or
Middle for the added speeds and High for the rated speed, thereby
allowing you to select the best speed for each set of traffic
conditions.
*3: For an escalator with a rated speed of 0.6m/sec, for example, additional speeds of 0.5m/sec and 0.3m/sec
can be set. For more information, consult our local agents.
ESCALATOR
SERIES Z
11 12
Cautions for outdoor use / Remote monitoring
Cautions for outdoor use
A roof must be provided over outdoor escalators. In rainy weather without a roof, passengers are in great danger of having their umbrellas
blown away by the wind or falling down on the slippery Steps. In hot weather, the Moving Handrails and Deck Boards can easily heat up
in the sun to a surface temperature exceeding 50°C, causing the unnecessary chance that passengers could get burnt on the
overheated elements. In addition, when not covered by a roof, the life and performance of outdoor escalators seriously deteriorate,
leading to shorter product life and higher cost for maintenance.
IMPORTANT INFORMATION
1. How to define outdoor escalators
Escalators are classified into three categories: outdoor, semi-outdoor and indoor. Outdoor escalators are defined as escalators exposed
to environmental factors such as wind, rain, snow or direct sunlight.
(6) Water in the lower pit will contain lubrication oil, so a grease trap should be provided to separate the
A B C ● Flooring within 300mm or 12” of the escalator Floor Plate must not be finished
lubrication oil from the water. The capacity of the grease trap is determined according to the escalator until the Floor Plates are in place
size and maximum amount of expected rainfall. ● Sprinkler pipes or wiring for soffit lights, or any other electric conduits for items
(7) Water may drip from the exterior panels of the escalator. Take waterproofing measures for equipment 30mm or more
other than escalator, must not be laid inside the truss
or items under the exterior panels if water is likely to cause problems or accidents.
● No walls or other parts of the building structure must be supported on the truss
Please consult our local agents for outdoor use. ● Allowable maximum weight of outer sheathing: 20kg/m2 or 0.028 psi
Remote monitoring
Mitsubishi Electric’s MelEye is a sophisticated Web-based elevator and escalator monitoring and control*1
Ordering information
system that allows authorized personnel to respond rapidly to changing traffic patterns and other operational Please submit the following information when ordering or requesting escalator quotations:
conditions. It improves passenger safety and reliability of your building management.
● Name and address of the building
User-friendly screens ● Escalator model (ZS or ZL or ZP)
● Escalator type (S1000 or S800 or S600)
● Rise (floor height) and number of floors
Interface
box ● Number of escalators
● Voltage and frequency of the power source for escalator’s main drive and lighting
Operational failures and errors ● Optional items required
will be highlighted for easier
recognition on the screen and to ● Whether or not fire-prevention shutters are required
improve rapid troubleshooting.
*1: Please note that MelEye is designed for monitoring of escalator operation, not to control the escalators remotely.
*2: Please consult our local agents for a brochure or further information.
13
Revised publication, effective Aug. 2022.
Superseding publication of L-170-6-C74881-N Nov. 2021.
Specifications are subject to change without notice.
L-170-6-C74881-O IN-2208 Printed in Japan (INADEN) ©2022 Mitsubishi Electric Building Solutions Corporation
For High Rise
Safety devices
The Series Z escalator is equipped with
For Japan Code
various safety devices that provide for
safety and reliability. For Japan Code
Specifications ●…Standard ○…Optional
N/A…Not applicable
Layout For Japan Code
Division Specification
ZS ZL ZP (Unit: mm)
Indoor ●
Environment Semi-outdoor ○
Outdoor ○ N/A ○
AC1 ●
Inverter (VVVF) ○ *1 Manhole cover Manhole cover
Control Automatic Operation with Posts (Stationary in stand-by, AC1) ○
Floor opening
RC, SRC structure Min. 270
system ○
120±10
Automatic Operation with Posts (Slow operation in stand-by, Inverter) Steel structure Min. 250 Comb Comb
W1+100
○
Finished floor level
Post-Free Automatic Operation (Slow operation in stand-by, Inverter) NK-865 NJ-865
Stop-Buzzer Key Switch ●
Anti-Slip Floor Plate ●
Step with Anti-Slip Grooves ● Anchor
Lower floor opening Wiring inlet (R.H.)
Max. LF Upper floor opening Max. UF
●
Support beam end
Demarcation Line
Truss end
Tiered Demarcation Line ●
Safety Support beam section detail (by owner)
Step Demarcation Lighting ○
features
Comb Light ○
Three Horizontal Steps ○
Warning System on Moving Handrail Inlet (Inlet Sensor) ○ *2
Warning System on Outer Deck (Outer Deck Sensor) ○ *2 N/A
○ *2 *3
LL=TG+250
Directional Indicator on Handrail Inlet Cap (Handrail Inlet Cap LED Indicator) 75
+40
75
Distance between support beams MM 0
Balustrade Transparent tempered glass panel ● N/A 50
+30
Truss length TG 50
+30
0
0
(See page 12 for Under-Handrail Lighting N/A ● N/A
TK HE/tan30° TJ
sections.) Stainless steel hairline panel N/A ●
●
LA Max. 11000 for S1000 LB Max. 11000 for S1000
Skirt Guard Stainless steel hairline Max. 11700 for S600 Max. 11700 for S600 Clearance
Fluoropolymer Coating ○ W1
Safety fence
NJ Min.2000
950
R2100
Step Aluminum alloy Step Tread ● RB
250
Aluminum alloy Cleat Riser ● F.L. F.L.
Wedge guard W.P.
Yellow Demarcation Line ● (by owner)
1030
Finish and NJ-385
Floor Plate Decorative Panel (Embossed stainless steel) ● 440 440
20
79
decorative Ceiling
Max. ZS / ZP : 13000
○ Recommended
0
Recommended
ZL : 9000
Min. 2120
Overhead
Floor Name Clearance
components Min. 2000 NK Wiring inlet (R.H.)
●
HE Rise
125
Comb
91
TJ-140
○
5
Extension of Floor Plate R1500
Truss
Connection of adjacent Floor Plates ○
Moving Handrail Rubber No. 0001 (Black) ● Outer sheathing
panel (by owner)
○
950
RC
30°
No. 0502 to 0508 (See page 5 for colors.) RA
SA
F.L.
Antibacterial Polyurethane *2 No. 9001 to 9010 (See page 9 for colors.) W.P. Intermediate support beam is
Moving ○ Floor opening
required when TG exceeds
1030
1100
13250mm for Type S1000
Handrail *5*6 NK-385 Min. 2000 Height of intermediate 13900mm for Type S600
support beams,180~1000.
Handrail Inlet Cap Plastic ●
Handrail Sterilizer *5 ○
Others MelEye ○
Automatic oiler ○
*1: Please consult our local agents for VVVF control.
*2: Not applicable to outdoor use.
*3: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas).
*4: Not applicable to semi-outdoor and outdoor use.
*5: Please consult our local agents if you require Handrail Sterilizer or Antibacterial Moving Handrail.
*6: Not applicable in some countries. Please consult our local agents for details. Please consult our local agents for:
- VVVF control (Please note that TJ may increase from that shown.)
- Reaction force, RA, RB, RC etc.
Escalators in the graphics are based on the Japan Code, with optional Fluoropolymer Coating on Skirt Guard.
jh2 jh3
For High Rise
Safety devices
The Series Z escalator is equipped with
For EN115 Code
various safety devices that provide for
safety and reliability. For EN115 Code
Division Specification
ZS ZL ZP (Unit: mm)
Indoor ●
Environment Semi-outdoor ○
Outdoor ○ N/A ○
AC1 ●
Inverter (VVVF) ○ *1 Manhole cover Manhole cover
Control
Automatic Operation with Posts (Stationary in stand-by, AC1) ○
Floor opening
system Comb
○
Comb
W1+100
Automatic Operation with Posts (Slow operation in stand-by, Inverter)
Post-Free Automatic Operation (Slow operation in stand-by, Inverter) ○ NK-865 NJ-865
120±10
Steel structure Min. 250
Anti-Slip Floor Plate ● Finished floor level
950
R2100
●
RB
Aluminum alloy Step Tread
250
Step F.L. F.L.
Aluminum alloy Cleat Riser ● Wedge guard W.P.
1030
(by owner) NJ-385
Yellow Demarcation Line
440 440
Finish and ● 20
79
Floor Plate Decorative Panel (Embossed stainless steel)
Max. ZS / ZP : 13000
Recommended Recommended Ceiling
0
ZL : 9000
Min. 2320
Overhead
Clearance
decorative Floor Name ○ Min. 2000 NK Wiring inlet (R.H.)
HE Rise
125
●
91
components Comb Truss TJ-140
5
R1500
Extension of Floor Plate ○
Connection of adjacent Floor Plates ○ Outer sheathing
panel (by owner)
Moving Handrail Rubber No. 0001 (Black) ●
950
RA RC
30°
○ F.L.
SA
No. 0502 to 0508 (See page 5 for colors.)
W.P. Intermediate support beam is
Antibacterial Polyurethane *2 No. 9001 to 9010 (See page 9 for colors.) required when TG exceeds
○
Floor opening
1030
1100
Moving Height of intermediate 13250mm for Type S1000
NK-385 Min. 2000
support beams,180~1000. 13900mm for Type S600
Handrail *5*6
Handrail Inlet Cap Plastic ●
Handrail Sterilizer *5 ○
Others MelEye ○
Automatic oiler ○
*1: Please consult our local agents for VVVF control.
*2: Not applicable to outdoor use.
*3: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas).
*4: Not applicable to semi-outdoor and outdoor use.
*5: Please consult our local agents if you require Handrail Sterilizer or Antibacterial Moving Handrail.
*6: Not applicable in some countries. Please consult our local agents for details.
Balustrade
Step ■Standard dimensions
Type S600 S1000
Skirt Guard
W1 (Escalator Width) 1150 1550
W2 (Between Moving Handrails) 840 1240
Floor Plate W3 (Between Skirt Guards) 610 1010
Horizontal Steps LF UF NK NJ
3 Steps 1440 1725 1975 2260
Operating Panel
Escalators in the graphics are based on the Japan Code, with optional Fluoropolymer Coating on Skirt Guard.
eh2 eh3