Professional Documents
Culture Documents
Name: No: Chemical Injection
Name: No: Chemical Injection
NO:
Chemical injection
12.2 : Make a table and describe where they used and why ?
Sodium Hypoclorite
Poly Electrolyte
Scale Inhibitor
Biocide A
Before filters to
Before filters & well
collect particles for
heads to prevent
smoothening filtration corrosion
Corrosion Inhibitor
At the inlet of
stripping tower to
prevent scale
Biocide B
Oxygen Scavenger
Demulsifir
TEG
In inlet manifold
headers and DH
header for separation
Used to dehydrate
wet gas
of water
12.3 : Calculate the chemical injection rate . How do you convert L/D to PPM and PPM to L/d ?
LPD={Production (bbl) x PPM x 159}/10^6
GPD = {production (bbl) xPPM x42 }/10^6
PPM = {L/D x 10^6 } / {production (bbl) x 159}
12.4: Adjust the chemical injection rate _ is it necessary to have this checked everyday ?
Close chemical tanks discharge valve
Check the rate of sight glass per minute
Multiply the number by 60 then 24 and divide the result to 1000
The result is the chemical injection per day
It is necessary to be checked daily because of any change in the rate could cause an
upset in the process
12.5 : Describe the correct protective clothing to wear when handling chemicals
-Plastic gloves
-Rubber Boats
-goggles/Face shield
-Face mask
-Rubber apron
12.6: What is the purpose of routine checks on chemical injection system and what are you looking
for?
To ensure that the chemical injection is going on with the specified rate
- Check the level in the tank
- Check the shower and eye wash station are available
- Check the pump is pumping
- Check for any leak
- Adjust the rate
12.7 : Receive and unload chemical deliveries taking all the necessary precautions
123456-
12.8 : Identify the chemical injection points in the various location of the fields
Demulsifir : (HP,IP,TEST) headers , DH header , SDH/SRT header
Scale inhibitor : Oxygen Stripping tower , main water injection header
Corrosion inhibitor : Disposal water tanks , wet gas header, some wellheads flow lines
Oxygen scavenger : Stripping tower outlet