Professional Documents
Culture Documents
LPG/C.ANNAPURNA
DATE
AT SEA
15
NOV
TIME
POSN.
PANEL
52
STARTED
1115Hr
STOPPED
INERT GAS GENERATOR
GENERATION MODE ( IG / DRY AIR )
AIR INLET PRESSURE TO BURNER
1930Hr
IG
0.38
(BAR)
FUEL OIL PRESSURE TO BURNER
(BAR)
FUEL OIL REGULATOR(INJECTION) POSI.
FUEL OIL PUMP PRESSURE
11
8/7
18
PANEL
(BAR)
DECK SUPPLY PRESSURE
160
147
(mBAR)
CONTROL AIR PRESSURE
7.0
145
78
(BAR)
AIR INLET PRESS. TO PILOT BURNER (BAR)
S/W INLET PRES.TO SCRUBBER
1.7
1.47
10
8/9
27
81
304
276
(BAR)
S/W INLET TEMP.TO SCRUBBER
S/W OUTLET TEMP.FROM SCRUBBER
AIR OUTLET TEMP.FROM SCRUBBER.
747
759
748
(BAR)
COMPRESSOR SUCTION TEMP.
COMPRESSOR DISCH. PRESSURE
( 0C)
-14
15.5
758
749
(BAR)
COMPRESSOR DISCH. TEMP.
COMPRESSOR L.O. PRESSURE
( 0C)
42
4.6
755
(BAR)
PRE COOLER PRESSURE
4.5
755
(BAR)
PRE COOLER TEMP.
-4
902
( C)
KNOCK OUT DRUM PRESSURE
(0C)
(0C)
(oC)
30
42
34
3.5
728
DRIER
PANEL
729
901
(BAR)
KNOCK OUT DRUM TEMP.
DRIER IN USE (FWD / AFT)
DRIER OUTLET PRESSURE
(BAR)
DRIER OUTLET TEMPERATURE
( C)
I.G. BLOWER.
PANEL BLOWER IN USE (PORT / STBD)
PANEL CURRENT - AMPERE
0.11
( 0C)
9
FWD
0.04
30
(AMPS)
OXYGEN ANALYSER
OXYGEN PERCENTAGE
%
STBD
96
3.5
DUTY ENGINEER
Signature