You are on page 1of 1

Air consumption calculations for pneumatic valves

Type

Status

Consumption
(Continous SCFM)

Consumption
(Intermittent SCFM)

Pipe Size (NB)

EFFLUENT TRANSFER RECIRCULATION VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

65

10GNK01AA008

FLASH MIXER INLET VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

65

10GNN03AA003

UF CIP INLET VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

65

10GNN03AA004

CIP INLET VALVE (RO VESSEL-I)OPEN FEED BACK

ON/OFF VALVE

NEW

50

10GNN04AA002

CIP OUTLET VALVE (RO VESSEL-III)OPEN FEED BACK

ON/OFF VALVE

NEW

50

10GNN04AA001

UF CIP OUTLET VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

65

10GNK05AA002

UF FEED-1 INLET VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

65

10GNK05AA004

UF PRODUCT WATER TANK INLET VALVE OPEN FEEDBACK

ON/OFF VALVE

NEW

65

10GNK05AA006

UF BACKWASH INLET VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

100

10

10GNK05AA007

UF BACKWASH OUTLET VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

100

11

10GNK05AA009

UF RECIRCULATION VALVE OPEN FEEDBACK

ON/OFF VALVE

NEW

25

12

10GNK06AA009

UF AIR COMPRESSOR VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

15

13

10GNK09AA400

RO DUMP VALVE OPEN FEED BACK

ON/OFF VALVE

NEW

50

SR. NO.

Valve Tag No.

10GNK01AA007X

Service

LEGENDS:
1 SCFM = STANDARD CUBIC FEET / MIN.
2. 1 SCFM = 1.7889 Nm3/hr

Total Consumption Continous

13

20% Spare

2.6

1.6

Total Estimated leakage=[Total + 20% Spare]*20%

3.12

1.92

Calculated Consumption during Normal Operation (Total Consumption Continuous + 20% Spare Capacity)

15.6

SCFM

Calculated Consumption during Peak Operation (Total Consumption Intermittent + 20% Spare Capacity)

9.6

SCFM

Calculated Total Consumption

25.2

SCFM

Remarks