Professional Documents
Culture Documents
PSV Sizing - Two Phase (Two-Points)
PSV Sizing - Two Phase (Two-Points)
PROJ. NO.:
DATE :
BY :
CLIENT :
UNIT :
REV :
DOC NO.:
S.Rahimi
Calculation Results
Relieving Pressure (Po)
Back Pressure (Pb)
c = Pc/Po
Critical Pressure (Pc)
Flow Regime
used Pb
Mass Flux (G)
Required Area for PRV
lb/hr
psig
%
R
psig
lb/ft3
lb/ft3
-------------
220000.0
217.50
10.0
771.00
15.00
7.59
6.12
0.85
1.00
1.00
1.00
psia
psia
------psia
---psia
lb/s ft2
in2
253.95
29.70
2.161
0.702
178.16
Critical
178.16
1426.6
7.3
Notes
www.chemwork.org
PROJECT :
PROJ. NO.:
DATE :
BY :
CLIENT :
UNIT :
REV :
DOC NO.:
Calculation Results
Relieving Pressure (Po)
Back Pressure (Pb)
s
st
Subcooling Region
s = Ps/Po
c
Critical Pressure (Pc)
Flow Regime
used as per type of flow regime
used P as per type of flow regime
Mass Flux
Required Area for PRV
gal/min
psig
%
R
psig
psia
lb/ft3
lb/ft3
-------------
100.0000
260.00
10.00
600.00
10.00
107.60
31.92
16.40
0.65
1.00
1.00
1.00
psia
psia
300.70
24.70
8.51
0.945
High
0.358
0.358
107.60
Critical
0.36
107.60
7560.5
0.21
psia
---psia
lb/s ft2
in2
General Notes
www.chemwork.org
S.Rahimi