You are on page 1of 4

Page 1 of 4

INPUT
Det. ID
Member No.
Joint No.

COLUMN DATA

UC 254x254x89

Depth of column ( D )
Width of column ( B )
Flange thickness ( T )
Web thickness ( t )
Root Radius ( r )
Cross-sectional area of column ( Acol )

=
=
=
=
=
=
=
=

Grade
Column yield strenght ( pyc )

Fc

260.30
256.30
17.30
10.30
12.70
11300.00
S275
265.00

mm
mm
mm
mm
mm
mm2
N/mm2

r
t

B
Table 9 - BS 5950 - 1:2000

COLUMN REACTIONS ( FACTORED FORCES )


Load Case No.
Max axial compression ( Fc )
Corresponding shear in direction of web ( Q1 )
Corresponding shear in direction of flange ( Q2 )

Q1

ANCHOR BOLTS DATA


Anchors grade
Anchors Diameter ( d )
Shear Strength ( ps )
Tension Strength ( pt )
Bearing strength ( pbb )
No. of rows
No. of Anchors per row
Total No. of Anchors
Tensile Area of Anchor ( As )
Anchors Gage ( G )
Spacing ( S )
Anchorage Length ( L )
Grout Thickness

Q2
FT

Q3

9
= 271.00
= 57.00
= 33.00

KN
KN
KN

Q4
=
=
=
=
=
=
=
=
=
=
=
=
=

8.8
20.00
375.00
560.00
1000.00
2.00
2.00
4.00
245.04
120.00
120.00
600.00
30.00

=
=
=
=
=
=
=

S275
20.00
265.00
410.00
460.00
270.00
270.00

=
=
=
=

70XX
225.50
10.00
4.00

mm
N/mm2
N/mm2
N/mm2

Table 30 - BS 5950 - 1:2000


Table 34 - BS 5950 - 1:2000
Table 31 - BS 5950 - 1:2000

mm2
mm
mm
mm
mm

BASE PLATE DATA


Plate grade
Plate Thickness ( tp )
Plate yield strength ( pyp )
Plate ultimate strength ( Us )
Bearing Strength of Base Plate ( pb )
Plate Width ( Bp )
Plate Length ( Dp )

mm

> T OK

N/mm2
N/mm2
N/mm2
mm
mm

Table 9 - BS 5950 - 1:2000

N/mm2
mm
mm

Table 37 - BS 5950 - 1:2000

Table 32 - BS 5950 - 1:2000

WELDING DATA
Electrode
Design strength of fillet weld ( pw )
Flange Weld Size ( sf )
Web Weld Size ( sw )
CONCRETE DATA
Grade
Characteristic cube Strength at 28 Days ( fcu )
Bearing Strength = 0.6 x fcu

= C35
= 35.00
= 21.00

BCSA - JISC - VOL 2 - P137

N/mm2
N/mm2

File: BP1

Page 2 of 4

CHECK 1 : EFFECTIVE AREA METHOD - BASE PLATE SIZE

BCSA - JISC - VOL 2 - P146

Ap Areq

Basic Requirement:
Where :

Ap = Area of Base Plate = Bp x Dp


= 270 x 270
Areq = Area Required = Fc / ( 0.6 x fcu )
= 271 x 1000 / ( 0.6 x 35 )
Therefore,
Ap

= 72900.00

mm2

= 12904.76

mm2

72900.00 mm2

Areq

>

= 12904.76 mm2

OK SAFE

Effective Area Calculation, Aeff


(i) Assuming no overlap
Aeff = (D+2K)(B+2K) - (D-2K-2T)(B-t)
= (DB + 2BK + 2DK + 4K2) - (DB - 2BK - 2BT - Dt + 2tK + 2Tt)
= 4K2 + (2D + 4B - 2t) K + (2BT + Dt - 2Tt)
4K2 + K ( Per col ) + Acol
Where :
Per col = (2D + 4B -2t) Column perimeter
= ( 2 x 260.3 + 4 x 256.3 - 2 x 10.3 )
Acol = (2BT + Dt - 2Tt) Column Area
= ( 2 x 256.3 x 17.3 + 260.3 x 10.3 - 2 x 17.3 x 10.3 )
Equating the effective area, Aeff to the required area, Areq (from check 1) gives
4 (K)^2 +1525.2 (K) + 11192.69
4 (K)^2 +1525.2 (K) - 1712.07

= 1525.2

mm

= 11192.69

mm2

= 12904.76
= 0

Solving For K ;
aK2 + bK + c
a= 4
b = 1525.20
c = -1712.07
K=

= 0

b b2 + 4ac
2a

(D - 2T ) / 2 = ( 260.3 - 2 x 17.3 ) / 2
hence, overlap doesn't occur & step (ii) is not applicable

= 1.12
Therefore, K = 1.12
= 112.85

OR
mm
mm

K = -382.42

>

1.12

(ii) Assuming overlap

N.A

Recalculate K on the basis of a revised effective area


Aeff = (D + 2K) (B + 2K)
= 4K2 + 2(D + B) K + DB
Equating the effective area, Aeff to the required area, Areq (from check 1) gives

N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A

4 (K)^2 +1033.2 (K) + 66714.89


4 (K)^2 +1033.2 (K) + 53810.13

= 12904.76
= 0.00

Solving For K ;
aK2 + bK + c
a= 4
b = 1033.20
c = 53810.1281
K=

b b2 + 4ac
2a

= 0

= -72.34

OR

K = 0.00

mm

Finaly, Overlap Doesn't occur [ step (i) is applicable ] & K = 1.12

mm

Also check that effective area fits on base plate


D + 2K = 260.3 + 2 x 1.12
B + 2K = 256.3 + 2 x 1.12

= 262.54
= 258.54

mm
mm

K = -185.96

N.A
N.A

<
<

CHECK 2 : EFFECTIVE AREA METHOD - BASE PLATE THICKNESS


Basic Requirement:

mm

Dp
Bp

=
=

270.00
270.00

mm
mm

OK SAFE
OK SAFE

20.00

mm

OK SAFE

BCSA - JISC - VOL 2 - P147

tp K ( 3 x 0.6 x fcu / pyp )

Where :
tp = Base Plate Thickness
pyp = Plate yield strength
fcu = concrete cube strength
Therefore,
tp min= K ( 3 x 0.6 x fcu / pyp )
tp min= 1.12 ( 3 x 0.6 x 35 / 265 )

= 20.00
= 265.00
= 35.00

mm

= 0.55

mm

N/mm2
2
N/mm

<

tp

File: BP1

Page 3 of 4

CHECK 3 : SHEAR CAPACITY OF COULUMN WEB TO BASE PLATE WELD


Basic Requirement:

Pweld = Capacity of fillet weld


= pw x lwew x a
pw = Design strenght of fillet weld
= 225.50
lwew = Effective length of weld to column web ( i.e in direction of Force )
= 2 (D - 2T - 2r - 2sw)
=
a=
=
=
Therefore,
Pweld =

BCSA - JISC - VOL 2 - P 148

Q1 Pweld

N/mm2

2 (260.3 - 2 x 17.3 - 2 x 12.7 - 2 x 4)


Throat Size
0.7 sw

= 384.60

mm

0.7 x 4

= 2.80

mm

pw x lwew x a

= 242.84

KN

CHECK 4 : SHEAR CAPACITY OF COLUMN FLANGE TO BASE PLATE WELD


Basic Requirement:

57.00

KN

OK SAFE

33.00

KN

OK SAFE

BCSA - JISC - VOL 2 - P 148

N/mm2

2 (256.3 - 2 x 10) + 2 (256.3 - 10.3 - 2 x 12.7 - 4 x 10)


Throat Size
0.7 sf

= 833.80

mm

0.7 x 10

= 7.00

mm

pw x lfw x a

= 1316.15

KN

Q2

>

CHECK 5 : SHEAR CAPACITY OF ANCHORS


Basic Requirement:

Q2 Pweld

Pweld = Capacity of fillet weld


= pw x lfw x a
pw = Design strenght of fillet weld
= 225.50
lfw = Effective length of weld to column flange ( i.e in direction of force )
= 2 (B - 2sf) + 2 ( B - t - 2r - 4sf )
=
a=
=
=
Therefore,
Pweld =

Q1

>

BCSA - JISC - MOMENT CONNECTIONS - P 97

H ns Pss + nt Pts

Where :
H=
=
ns =
Pss =
ps As =
d tp p b =
6 d2 fcu =
nt =
Pts =
0.4 ps As =
d tp p b =
6 d2 fcu =

Design horizontal shear force


= 65.86
Q12 + Q22
No. of bolts in non tension zone
= 4.00
Shear capacity of single bolt in the non tension zone which is the lesser of :
375 x 245.04 / 1000
= 91.89
20 x 20 x 460 / 1000
= 184.00
6 x 20^2 x 35 / 1000
= 84.00
Therefore, Pss = 84.00
No. of bolts in the tension zone
= 0.00
Shear capacity of single bolt in the tension zone which is the lesser of :
0.4 x 375 x 245.04 / 1000
= 36.76
20 x 20 x 460 / 1000
= 184.00
6 x 20^2 x 35 / 1000
= 84.00
Therefore, Pts = 36.76

Therefore,
H= Q12 + Q22

= 65.86

KN

KN
KN
KN
KN

KN
KN
KN
KN
KN

<

CHECK 6 : CHECK OF FLANGE WELDING FOR CASE OF COMPRESSION FORCE

ns Pss + nt Pts

336.00

KN

OK SAFE

BCSA - JISC - MOMENT CONNECTIONS - P 98

( Assuming that the contact faces of the column & base plate are not in tight bearing )
Basic Requirement:

FC Pweld

Where ;
FC = Minimum of :
i ) The crushing capacity of the flanges = 2 x B x T x py
= 2 x 256.3 x 17.3 x 265 / 1000
ii ) The flange compression force = 2 x Fc x B x T / Acol

= 2350.01

KN

= 212.67
= 212.67

KN
KN

= 225.50

N/mm2

2 (256.3 - 2 x 10) + 2 (256.3 - 10.3 - 2 x 12.7 - 4 x 10)


Throat Size
0.7 sf

= 833.80

mm

0.7 x 10

= 7.00

mm

pw x lfw x a

= 1316.15

KN

= 2 x 271 x 256.3 x 17.3 / 11300


FC = Minimum of (i) & (ii)
Pweld = Capacity of fillet weld
= pw x lfw x a
pw = Design strength of fillet weld
lfw = Effective length of weld to column flange
= 2 (B - 2sf) + 2 ( B - t - 2r - 4sf )
=
a=
=
=
Therefore,
Pweld =

>

FC

212.67

KN

OK SAFE

File: BP1

Page 4 of 4

CHECK 7 : CHECK OF WEB WELDING FOR COMBINED COMPRESSION & SHEAR


Basic Requirement:

FTOT Pweld

Where ;
FTOT = Q12 + ( Fc x D x t / Acol. )2
= (57)^2 + (271 x 260.3 x 10.3 / 11300) ^2
Pweld = pw x lwew x a
Therefore,
FTOT = Q12 + ( Fc x D x t / Acol. )2

= 85.93
= 242.84

KN
KN

= 85.93

KN

Refer to CHECK 3
<

P weld =

242.84

KN

OK SAFE

P weld =

1316.15

KN

OK SAFE

CHECK 8 : CHECK OF FLANGE WELDING FOR COMBINED COMPRESSION & SHEAR


Basic Requirement:

FTOT Pweld

Where ;
FTOT = Q22 + ( 2 x Fc x B x T / Acol )2
= (33)^2 + (2 x 271 x 256.3 x 17.3 / 11300) ^2
Pweld = pw x lfw x a
Therefore,
FTOT = Q22 + ( 2 x Fc x B x T / Acol )2

= 215.22
= 1316.15

KN
KN

= 215.22

KN

Refer to CHECK 4
<

File: BP1