Guardamotores - SIEMENS
Guardamotores - SIEMENS
SIRIUS
Description
Ordering Information
Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only.
Illustration
FLA
Adjustment
Range
Single-Phase
HP Ratings
115V
230V
Three-Phase HP Ratings
200V
230V
460V
575V
Instantaneous
UL Short-circuit
Screw connection
short-circuit release breaking capacity
@ 480 VAC
>
List
cu
A
kA
Catalog No
Price $
1
10
1
8
1
6
1
4
1
3
1
2
1
2
1
1 12
2
2
1
10
1
8
1
6
1
4
1
3
1
2
3
4
1
1 12
2
3
3
3
5
1
2
3
4
3
4
1
1 12
2
3
3
5
5
7 12
7 12
1
2
3
4
1
1
1 12
2
3
3
5
7 12
7 12
7 12
1
2
3
4
3
4
1
1 12
1 12
2
3
5
5
7 12
7 12
10
15
15
15
1
2
1
2
3
4
1
1 12
1 12
2
3
3
5
5
10
10
15
20
20
20
2.1
2.6
3.3
4.2
5.2
6.5
8.2
10
13
16
21
26
33
42
52
65
82
104
130
163
208
260
286
325
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
3RV1021-0AA10
3RV1021-0BA10
3RV1021-0CA10
3RV1021-0DA10
3RV1021-0EA10
3RV1021-0FA10
3RV1021-0GA10
3RV1021-0HA10
3RV1021-0JA10
3RV1021-0KA10
3RV1021-1AA10
3RV1021-1BA10
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1EA10
3RV1021-1FA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4CA10
3RV1021-4DA10
5
5
7 12
10
15
15
15
5
7 12
10
10
15
15
20
10
15
20
25
30
30
40
15
20
25
30
40
40
50
208
260
325
416
520
585
650
65
65
65
65
65
65
65
3RV1031-4AA10
3RV1031-4BA10
3RV1031-4DA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4GA10
3RV1031-4HA10
15
15
20
25
30
40
15
20
25
25
30
40
30
40
50
60
75
75
40
50
60
75
100
100
520
650
819
975
1170
1235
65
65
65
65
65
65
3RV1041-4FA10
3RV1041-4HA10
3RV1041-4JA10
3RV1041-4KA10
3RV1041-4LA10
3RV1041-4MA10
1
1 12
2
3
3
5
5
3
3
5
5
7 12
7 12
10
3
5
5
7 12
10
10
7 12
10
15
15
20
25
Refer to pages 1/20 to 1/22 when using an MSP in a Manual Motor Starter or a Manual Self-Protected Combination Motor Controller.
1/5
SIRIUS
3RV10 Class 20
up to 100A
Description
Ordering Information
The 3RV103 and 3RV104 MSPs can be used as Type E selfprotected manual combination starters per UL508 (3RV104
requires an additional terminal block) or as components in
Group Installation per NEC 430-53(C) to turn motors on and off.
(Note: the 3RV104 requires the line side adapter 3RT19464GA07 to meet the Type E.) Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the 3RV is used as a component in Group Installation, multiple MSPs can be installed
below one circuit breaker to protect its own motor. A contactor
can be mounted to the MSP to provide a remotely operated
starter.
Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only.
Illustration
FLA
Adjustment
Range
Single-Phase
HP Ratings
115V
230V
Three-Phase HP Ratings
200V
230V
460V
575V
Instantaneous
UL Short-circuit
Screw connection
short-circuit release breaking capacity
@ 480 VAC
>
List
cu
A
kA
Catalog No
Price $
1
1 12
2
3
3
5
5
3
3
5
5
7 12
7 12
10
5
5
7 12
10
15
15
15
5
7 12
10
10
15
15
20
10
15
20
25
30
30
40
15
20
25
30
40
40
50
208
260
325
416
520
585
650
65
65
65
65
65
65
65
3RV1031-4AB10
3RV1031-4BB10
3RV1031-4DB10
3RV1031-4EB10
3RV1031-4FB10
3RV1031-4GB10
3RV1031-4HB10
3
5
5
7 12
10
10
7 12
10
15
15
20
25
15
15
20
25
30
40
15
20
25
25
30
40
30
40
50
60
75
75
40
50
60
75
100
100
520
650
819
975
1170
1235
65
65
65
65
65
65
3RV1042-4FB10
3RV1042-4HB10
3RV1042-4JB10
3RV1042-4KB10
3RV1042-4LB10
3RV1042-4MB10
3RV103
1116
1420
1825
2232
2840
3645
4050
3RV104
2840
3650
4563
5775
7090
80100
Refer to pages 1/20 to 1/22 when using an MSP in a Manual Motor Starter or a Manual Self-Protected Combination Motor Controller application.
1/6
SIRIUS
Design
For
SIRIUS MSP
Frame Size
Screw connection
Order No.
List
Price $
Weight
approx.
kg
Transverse auxiliary
switch 2)
SPDT contact
1 NO + 1 NC
2 NO
3RV19 01-1D
3RV19 01-1E
3RV19 01-1F
0.02
Solid-state compatible,
SPDT contact
transverse
auxiliary switch 2)
with screw connection
for use in dusty atmosphere and
in electronic circuits with low operating currents
Covering caps for
transverse auxiliary switches
3RV19 01-1G
0.02
3RV19 01-0H
Signaling switch
(Side Mount)
Auxiliary switches 1)
3RV19 01-1E
3RV1901-1G
3RV1901-0H
3RV1901-1A 3RV1901-1J
Standard
package
quantity=10
3RV19 01-1A
3RV19 01-1B
3RV19 01-1C
3RV19 01-1J
0.03
S0, S2, S3
3RV19 21-1M
0.07
3RV19 02-1AB4
0.12
0.06
Signalling switch 3)
3RV19 21-1M
Auxiliary releases 4)
3RV19 02-1DP0
Undervoltage
release
(Side Mount)
DC
3RV19 12-1CP0
Undervoltage
release with
leading auxiliary
contacts 2 NO
(Side Mount)
Shunt release
(Side Mount)
24 V
AC 50 Hz
AC 60 Hz
20-24 V
90-110 V
210-230 V
400 V
350-415 V
500 V
120 V
208 V
240 V
480 V
3RV19 02-1AB0
3RV19 02-1AF0
3RV19 02-1AM1
3RV19 02-1AP0
3RV19 02-1AV0
3RV19 02-1AV1
3RV19 02-1AS0
0.12
230 V
400 V
415 V
230 V
400 V
415 V
240 V
480 V
240 V
480 V
S00
3RV19 12-1CP0
3RV19 12-1CV0
3RV19 12-1CV1
3RV19 22-1CP0
3RV19 22-1CV0
3RV19 22-1CV1
0.11
AC 50/60 Hz
100% ON 5)
AC 50/60 Hz; DC
5 sec ON 6)
20 24 V
90110 V
200240 V
350415 V
500 V
20 70 V
70190 V
190330 V
330500 V
500 V
3RV19 02-1DB0
3RV19 02-1DF0
3RV19 02-1DP0
3RV19 02-1DV0
3RV19 02-1DS0
0.11
S0, S2, S3
Note: As of July 2001, UL 508 demands for "Combination Motor Controller Type E" 1" air gaps and 2" creepage distances at lineside. The following terminal blocks must be used in S0 and S3 MSPs 3RV10. The S2 MSP 3RV10 conforms with stipulated air gaps
and creepage distances without terminal block.
Terminal blocks are not required for use according to CSA. With size S0 these terminal blocks cannot be used in combination with
3-phase busbars 3RV19.5. This also applies to size S3 in combination with transverse auxiliary switches.
Terminal block type E
3RT19 46-4GA07
1) Each MSP can be fitted with one transverse and one lateral auxiliary
switch. The lateral auxiliary switch with 2 NO + 2 NC is used without
transverse auxiliary switch.
2) Compatible with the following MSPs:
3RV1. 1 (size S00) as of version E01
3RV1. 2 (size S0) as of version E04
3RV1. 3 (size S2) as of version E04
3RV1. 4 (size S3) as of version E04.
S0
3RV19 28-1H
0.12
S3
3RT19 46-4GA07
0.12
1/9
Busbar Accessories
SIRIUS
Incl.
lateral
auxiliary
switch
With
auxiliary trip
unit
mm
Rated
current
In at
690 V
For motor
starter
protectors
Size
Order No.
List
Price $
PU
PS
(UNIT,
SET, M)
Weight
per PU
approx.
kg
3RV19 15-1AB
3RV19 15-1BB
3RV19 15-1CB
3RV19 15-1DB
1)
2
3
4
5
--
--
63
S00, S01)2)
S00, S01)2)
S00, S01)2)
S00, S01)2)
3RV19 15-1AB
3RV19 15-1BB
3RV19 15-1CB
3RV19 15-1DB
1
1
1
1
1 unit
1 unit
1 unit
1 unit
0.044
0.071
0.099
0.124
55
--
2
3
4
5
--
63
S00, S01)2)
S00, S01)2)
S00, S01)2)
S00, S01)2)
3RV19 15-2AB
3RV19 15-2BB
3RV19 15-2CB
3RV19 15-2DB
1
1
1
1
1 unit
1 unit
1 unit
1 unit
0.048
0.079
0.111
0.140
63
--
--
2
4
63
S00, S01)2)
S00, S01)2)
3RV19 15-3AB
3RV19 15-3CB
1
1
1 unit
1 unit
0.052
0.120
55
2
3
4
--
--
108
S2
S2
S2
3RV19 35-1A
3RV19 35-1B
3RV19 35-1C
1
1
1
1 unit
1 unit
1 unit
0.150
0.214
0.295
75
--
2
3
4
2
3
4
108
S23)
S23)
S23)
3RV19 35-3A
3RV19 35-3B
3RV19 35-3C
1
1
1
1 unit
1 unit
1 unit
0.161
0.262
0.369
Not suitable for 3RV11 motor starter protectors with overload relay function. Common clamping of S00 and S0 motor starter protectors is not possible, due to the different modular spacings and terminal heights. The
3RV19 15-DB connecting piece is available for connecting busbars from
size S0 to size S00.
Version
Modular
spacing
For motor
starter
protectors
Size
2)
3)
Auxiliary trip units and lateral auxiliary switches cannot be used in combination.
Order No.
List
Price $
PU
PS*
(UNIT,
SET, M)
Weight
per PU
approx.
kg
mm
3RV19 15-5DB
S00, S0
3RV19 15-5DB
Conductor cross-section
For motor
starter
protectors
Size
Order No.
Solid or Finely
stranded stranded
with end
sleeve
Tightening
torque
AWG
cables,
solid or
stranded
mm
AWG
mm
List
Price $
1 unit
PU
PS*
(UNIT,
SET, M)
Nm
0.042
Weight
per PU
approx.
kg
3RV19 25-5AB
12-4
S00
3RV19 15-5A
1 unit
0.040
S0
3RV19 25-5AB
1 unit
0.041
Input: 4,
Output:
2 ... 2.5
S00, S0
3RV19 15-5B
1 unit
0.110
S2
3RV19 35-5A
1 unit
0.110
3RV19 25-5EB
3RV19 35-5E
1
1
1 unit
1 unit
0.055
0.100
12-4
10-4
8-0
2-4
4.5-6
S0
S2
1/10
SIRIUS
Accessories
Design
Order No.
List
Price $
Weight
approx.
kg
Std.
pkg.
qty
1 NO + 1 NC
3RV19 01-2E
0.02
1 NO + 1 NC
3RV19 01 -2A
0.03
2 NO
3RV19 01 -2B
2 NC
3RV19 01 -2C
Size S00
3RA19 11-2A
0.12
10
Size S00
3RA19 11-2E
0.03
10
45 mm wide
3RA19 22-1L
0.26
60 mm wide
8US12 51-5CM47
0.17
45 mm wide
8US19 98-7CA15
0.09
Length approx.
175 mm
8WA2 8032)
0.012
3RA1911-2E
Link module,
Cage Clamp
for electrical contacting between
MSP and contactor
(busbar adapter not included in the scope of
delivery)
Link module, Cage Clamp, for mechanical
fixing
for mechanical fixing and electrical contacting between MSP and contactor
Adapter for rail mounting
for Cage Clamp with 2 mounting rails,
one adjustable
Busbar adapter
45 mm wide, 182 mm long
adapted for Cage Clamp
MSP. An additional standard mounting rail
must be used if increased protection is
required.
35 mm standard mounting rail,
plastic, includes
fixing screws
10
1/11
Accessories
SIRIUS
Mounting accessories
Selection and ordering data
Type
Design
For
SIRIUS
MSP
size
Push-in lugs
Order No.
List
Price $
Standard Weight
Package approx.
Quantity
kg
Mounting accessories
3RB19 00-0B
3RB19 00-0B
10
0.01
3RV19 18-5A
0.10
3RV19 18-5B
0.19
Isolator module
3RV19 38-1A
with padlock
Isolator module
3RV19 28-1A
0.15
3RV19 38-1A
0.29
3RT19 46-4F
0.10
0.03
0.03
0.04
0.05
0.08
0.04
0.05
0.08
S3
Link modules
3RA19 11-1AA00
Link module
for mechanical fixing and
electrical contacting
between contactor and
MSP
3RA19 31-1AA00
Contactor
MSP
AC and DC
AC and DC
AC
AC
AC
DC
DC
DC
S00
S00
S0
S2
S3
S0
S2
S3
S00
S0
S0
S2
S3
S0
S2
S3
3RA19 11-1AA00
3RA19 21-1DA00
3RA19 21-1AA00
3RA19 31-1AA00
3RA19 41-1AA00
3RA19 21-1BA00
3RA19 31-1BA00
3RA19 41-1BA00
AC/DC
S00
S00
S00
S0
3RA19 11-2FA00
3RA19 21-2FA00
1
1
0.038
0.028
3RA19 11-2FA00
1/12
SIRIUS
Accessories
Design
For
SIRIUS
MSP
size
Order No.
List
Price $
Weight
approx.
kg
The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and an extension shaft of 330 mm length (6 mm
6 mm). The door-coupling rotary operating mechanisms are designed for degree of protection IP 65. The door locking device prevents accidental opening of the cubicle door in the ON position of the MSP. The OFF position can be locked with up to 3 padlocks.
Door-coupling
Extension shaft 130 mm
rotary operating mech- Extension shaft 330 mm
anism, black
with supporting bracket
S0, S2, S3
EMERGENCY STOP
Extension shaft 130 mm
door-coupling
Extension shaft 330 mm
rotary operating mech., with supporting bracket
red/yellow
3RV19 26-0B
3RV19 26-0K
0.1
0.3
3RV19 26-0C
3RV19 26-0L
0.1
0.3
The door-coupling rotary operating mechanisms consist of a knob, a coupling driver, an extension shaft of 300 mm length (8 mm
8 mm), a spacer and two metal brackets, into which the MSP is inserted. The door-coupling rotary operating mechanisms are
designed for degree of protection IP 65. The door locking device reliably prevents accidental opening of the cubicle door in the ON
position of the MSP.
The OFF position can be locked with up to 3 padlocks. Auxiliary releases for lateral mounting and 2-pole auxiliary switches can be
used. The door-coupling rotary operating mechanism thus conforms with isolator characteristics to IEC 60 947-2.
Door-coupling
rotary operating
mechanism, grey
S0
S2
S3
3RV29 26-2B
3RV29 36-2B
3RV29 46-2B
1.2
1.6
1.7
EMERGENCY STOP
door-coupling
rotary operating mech.,
red/yellow
S0
S2
S3
3RV29 26-2C
3RV29 36-2C
3RV29 46-2C
1.2
1.5
1.7
S2
3RV19 36-3AP0
3RV19 36-3AB4
3.5
3.4
S3
3RV19 46-3AP0
3RV19 46-3AB4
3.4
3.4
Remote-controlled
motorized operating
mechanism
Mounting accessories
Selection and ordering data
Type
Design
For
circuitbreaker
size
Order No.
List
Price $
Weight
approx.
kg
Covers
3RV1 (size S3) with
3RT19 46-4EA1
Terminal cover
for box terminals
Terminal cover
for cable lug and
bar connection
3RV19 08-0P
Scale cover
sealable
3RT19 36-4EA2
3RT19 46-4EA2
0.01
3RT19 46-4EA1
0.03
3RV19 08-0P
Standard
package
quantity=10
1/13