R&S Test Engine:

Press a key when MS is displaying 'In Service' ... Done


The SS is going to request to setup a MO call. During the call
setup it will send the AoCC information in CONNECT message in state U4
Please initiate a normal call by dialling 1234 <SEND>
Rx Channel Request
.. 1 1 5890 ok
Tx Immediate Assignment
.. 1 1 5925 ok
SDCCH/4(0)
Rx CM Service Req
.. 1 1 5956 ok
Tx CM Service Accept
.. 1 1 6043 ok
Rx CC Setup
.. 1 1 6109 ok
Dual FR preferred
Speech
Tx CC Call Proceeding
.. 1 1 6196 ok
Bearer Capability Omitted
SS Setting RF Levels .. ok
Tx Power Level for Channel 17 set to -50.0 dBm
Tx Assignment Command
.. 1 1 6247 ok
TCH/F Speech v1
Rx DL-Establish-Ind
.. 1 2 6273 ok
Rx Assignment Complete
.. 1 2 6303 ok
Tx Alerting
.. 1 2 6321 ok
Tx CC Connect
.. 1 2 6412 ok
Rx CC Connect Ack
.. 1 2 6425 ok
Rx CRSS Facility
.. 1 2 6455 ok
Requirement 27.21.3 General : PASS
CONNECT ACK has been received from the MS
Requirement 27.21.3 General : PASS
AoCC information in FACILITY has been acknowledged by the MS
FACILITY message arrived within time (212 ms)
The RETURN RESULT IE is present in the Facility message
Step b) The SS is going to wait for the MS to clear the call with cause
value 68hex
Rx CC Disconnect
.. 1 2 10775 ok
Tx CC Release
.. 1 2 10793 ok
Rx CC Release Complete
.. 1 2 10806 ok
Tx Channel Release
.. 1 2 10823 ok

Rx DL-Release-Ind
.. 1 2 10836 ok
The MS did not clear the call between 29 and 31 seconds
Actual: 20.136Sec
Call should be cleared between 29-30 as per the spec.
FAILURE: CheckTimeToClear(...)
Please switch the Mobile Station Off
Press any key to continue
Final Verdict 27.21.3: FAIL