2. When IDUs complete the booting sequence, verify:
All IDUs have the same HW version (same P/N)
All IDUs have the same SW version All IDUs have the same license Every IDU has unique IP address (within the same subnet) Active and STBY have the same SW mode (Pipe / Managed / Metro) All IDUs have the same Management mode (In band or OOB) In case of In-Band, all IDUs have the same In-Band VID
Note: The IDU, which is connected to the ODU fed by the lower attenuation channel of the RF coupler, is the IDU that should be selected as "Active.
Configuring external 1+1 from scratch (2)
3. Install the first link (make sure radio is up) 4. Enable Protection on both IDUs (management will be lost for 60 sec) 5. Lock Protection on both IDUs (to avoid unnecessary switchover when second IDU is enabled) 6. Install second IDU in each site (no need to configure it) 7. Enable protection in second IDU in each site 8. Connect ETH Cross Cable between both protection ports. In case of Nodal Enclosure, turn-off the protection IDU and insert it inside the enclosure . Turn on again the protection IDU. 10. Connect the PC to IDUs via ETH Y-Cable 11. Verify Active IDU shows Mates IP address 12. Verify there are no Configuration Mismatch alarms 13. Verify there are no Mate Communication failures 14. Complete system setup by configuring Active IDU 15. In Active IDU: click Copy to Mate and verify Mate is restarting 16. Unlock protection on Active IDUs 17. Initiate Manual Switchover / Forced Switchover: verify traffic is OK.