HIGH PERFORMANCE STEEL ANCHORS

fischer Bolt FBN


The flexible anchor for economical performance.

Suitability

Suitable for:
Concrete so B15, natural stone with dense
structure.
For fixing of:
Metal constructions, metal profiles, sole plates, brackets,
railings, windows, gratings, machines, timber constructions
(large washer), beams, purlins, supports etc.

2
3
4

fischer Bolt FBN,


zinc plated and passivated steel
fischer Bolt FBN with large washer,
zinc plated and passivated steel
fischer Bolt FBN, A4 stainless steel*
fischer Bolt FBN fvz (hot dipped galvanized)*
* not included in approval notice.

Description
The fischer FBN bolt is a more advanced development of the
FB and now offers even more scope for application. In
concrete terms, this means that the FBN can be installed
with a variable embedment depth, i.e. the user has the
choice between the standard embedment depth with
maximum permitted load and an extended useful length with
a reduced permitted load. The thread has been extended
with this in mind.

Installation instructions

Advantages

 Before tapping in, place the nut in the best position for
installation (bolt projects approx. 23 mm).

 Through its variable useful length (see description) and the


extended thread, the FBN offers increased scope for use.

 The letter engraved on the head of the anchor is required


for approval reasons and identifies the FBN in its installed
state.

 The expansion clip has been improved, resulting in increased load values, even in low-quality concrete.
 Anchoring with the FBN is now even more economical.
 The FBN can be anchored with only a few turns.
 A special assortment with a large washer to DIN 440 is
available for use with wood.

Approvals

Fire resistance
classification

F 90

Installation diagram

32

HIGH PERFORMANCE STEEL ANCHORS

fischer Bolt FBN


Technical data

FBN zinc plated and passivated steel


do

FBN A4 stainless steel

Type

Imprint Steel
on
gvz
head Art. No.

Steel
A4*
Art. No.

Drill

mm

td
Min.
drill-hole
depth for
through
fixing
mm

FBN 6x40*
FBN 6x55*
FBN 6x70
FBN 6x75*
FBN 6x90
FBN 8x60
FBN 8x75
FBN 8x95
FBN 8x115
FBN 8x165
FBN 10x70
FBN 10x90
FBN 10x110
FBN 10x125
FBN 10x175
FBN 10x215
FBN 10x235
FBN 12x85
FBN 12x115
FBN 12x130
FBN 12x145
FBN 12x200
FBN 16x110
FBN 16x145
FBN 16x170
FBN 16x220
FBN 20x120*
FBN 20x165
FBN 20x205
FBN 20x265
FBN 20x395

B
F
K
P

C
G
K
P
S
T

C
F
I
P

E
K
P

69087

69088

69089
69090
69091

69092

69093
69094

69095

69096
69097
69098
69099
69100

6
6
6
6
6
8
8
8
8
8
10
10
10
10
10
10
10
12
12
12
12
12
16
16
16
16
20
20
20
20
20

45
50
65
70
85
55
73
93
113
163
65
83
103
118
168
208
228
75
105
120
135
190
98
133
158
208
111
151
191
251
381

45130
45136

45137

45131
45138
45139
45140
45141
45132
45142
15399
45143
45144
45145
45146
45133
45147
45148
45149
45150
45134
45151
45152
45153
45135
45154
45155
45156
45157

hef

FBN fvz (hot dipped galvanized)

tfix

do

Min.
anchorage
depth
mm

Overalllength
mm

Max.
fixing
thickness
mm

Thread
 x length

Qty.
per
pack

20
25
40
25
40
35
48/35
48/35
48/35
48/35
42
50/42
50/42
50/42
50/42
50/42
50/42
50
70/50
70/50
70/50
70/50
64
84/64
84/64
84/64
70
100
100
100
100

40
55
70
75
90
60
75
95
115
165
70
90
110
125
175
215
235
85
115
130
145
200
110
145
170
220
120
165
205
265
395

5
10
10
30
30
5
10/23
30/43
50/63
100/113
5
15/23
35/43
50/58
100/108
140/148
160/168
5
15/35
30/50
45/65
100/120
10
25/45
50/70
100/120
10
20
60
120
250

M 6 x 16
M 6 x 30
M 6 x 25
M 6 x 30
M 6 x 30
M 8 x 23
M 8 x 41
M 8 x 61
M 8 x 81
M 8 x 130
M10 x 31
M10 x 51
M10 x 71
M10 x 87
M10 x 134
M10 x 174
M10 x 194
M12 x 41
M12 x 71
M12 x 86
M12 x 103
M12 x 157
M16 x 54
M16 x 89
M16 x 114
M16 x 166
M 20 x 50
M 20 x 50
M 20 x 90
M 20 x 90
M 20 x 90

100
100
100
100
100
100
50
50
50
25
50
50
50
20
20
20
20
20
20
20
20
20
10
10
10
10
10
10
10
10
5

* not included in approval notice.

FBN with large washer according to DIN 440, outside diameter approx. 3.5 x d
do

Type

Imprint
on
head Art. No.

Drill

mm

td
Min.
drill-hole
depth for
through
fixing
mm

FBN 12x180 GS
FBN 12x200 GS
FBN 12x220 GS
FBN 12x240 GS
FBN 12x260 GS
FBN 12x300 GS
FBN 12x350 GS
FBN 16x220 GS
FBN 16x260 GS
FBN 16x280 GS
FBN 16x320 GS
FBN 16x370 GS
FBN 16x420 GS

N
P
R
S
T
V
W
P
S
T
V
W
X

12
12
12
12
12
12
12
16
16
16
16
16
16

170
190
210
230
250
290
340
208
248
268
308
358
408

1)

2)

45160
45161
45162
45163
45164
45165
45166
45167
45168
45169
45170
45171
45172

hef

tfix

Min.
Anchorage
depth
mm

Overall
length
mm

Max.
fixing
thickness
mm

Thread
 x length

70/50
70/50
70/50
70/50
70/50
70/50
70/50
84/64
84/64
84/64
84/64
84/64
84/64

180
200
220
240
260
300
350
220
260
280
320
370
420

80/100
100/120
120/140
140/160
160/180
200/220
250/270
100/120
140/160
160/180
200/220
250/270
300/320

M12 x 137
M12 x 157
M12 x 177
M12 x 100
M12 x 100
M12 x 100
M12 x 100
M16 x 166
M16 x 100
M16 x 100
M16 x 100
M16 x 100
M16 x 100

Qty.
per
pack

20
20
20
10
10
10
10
10
10
10
10
10
10

Min. embedment depth for maximum permitted load/the minimum embedment depth can be
reduced to . . . for the extended effective length and reduced load.
Embedment length for maximum permissible load/embedment length for reduced load.

Type

Steel
fvz*
Art. No.

Drill

mm

td
Min.
drill-hole
depth for
through
fixing
mm

FBN 8x60 HDG*


FBN 8x75 HDG*
FBN 8x115 HDG*
FBN 8x165 HDG*
FBN 10x70 HDG*
FBN 10x90 HDG*
FBN 10x125 HDG*
FBN 10x175 HDG*
FBN 10x215 HDG*
FBN 12x85 HGD*
FBN 12x115 HDG*
FBN 12x130 HDG*
FBN 12x145 HDG*
FBN 12x200 HDG*
FBN 16x110 HDG*
FBN 16x145 HDG*
FBN 16x170 HDG*
FBN 16x220 HDG*

57525
57526
57527
57528
57529
57530
57531
57532
57533
57534
57535
57536
57537
57538
57539
57540
57541
57542

8
8
8
8
10
10
10
10
10
12
12
12
12
12
16
16
16
16

55
73
113
163
65
83
118
168
208
75
105
120
135
190
98
133
158
208

hef

tfix

Min.
Anchorage
depth
mm

Overall
length
mm

Max.
fixing
thickness
mm

Thread
 x length

Qty.
per
pack

60
75
115
165
70
90
125
175
215
85
115
130
145
200
110
145
170
220

5
10
50
100
5
15
50
100
140
5
15
30
45
100
10
25
50
100

M 8 x 23
M 8 x 41
M 8 x 81
M 8 x 130
M10 x 31
M10 x 51
M10 x 87
M10 x 134
M10 x 174
M12 x 41
M12 x 71
M12 x 86
M12 x 103
M12 x 157
M16 x 54
M16 x 89
M16 x 114
M16 x 166

100
50
50
25
50
50
20
20
20
20
20
20
20
20
10
10
10
10

35
48
48
48
42
50
50
50
50
50
70
70
70
70
64
84
84
84

* Not included in approval notice.

Mean ultimate loads and recommended loads for single


anchors of fischer bolt FBN with large axial spacing and
edge distance
Non-cracked concrete
Anchor size

M6

M8

M10

Effective anchorage depth


heff [mm]
40
35
48
42
Drill hole depth
h1  [mm]
55
50
63
60
Drill hole diameter
do [mm]
6
8
8
10
Mean ultimate loads Nu,m and Vu,m [kN]
Tensile
0 Nu,m [kN] gvz

14.3* 19.2
[kN] fvz

15.5*
[kN] A4 10.6* 16.4 20.5
Shear
90 Vu,m [kN] gvz

11.3* 16.6*
[kN] fvz

12.3*
[kN] A4 9.0* 15.1* 24.0*
Recommended loads Nrec and Vrec [kN]
Tensile
0 Nrec [kN] gvz

2.5 4.4 4.7


[kN] fvz

4.8

[kN] A4 3.3

4.4 4.7
Shear
90 Vrec [kN] gvz

3.2 5.3 5.8


[kN] fvz

6.7

[kN] A4 4.3

5.3 5.8
Recommended bending moment Mrec [Nm]
Mrec [Nm] gvz
10.5 10.5 21.4
[Nm] fvz

13.7
[Nm] A4 6.5 14.7 14.7 29.7
Component dimensions, minimum axial spacings and edge distances
Min. axial spacing1)
smin [mm] gvz

35
50
45
fvz

50

A4
40

50
50
Min. edge distance1)
cmin [mm] gvz

35
50
55
fvz

50

A4
35

35
60
Min. structural component
100 100 100 100
hmin [mm]
thickness
7.5 15
15
30
Required torque
Tinst [Nm]

M12

M16

50
68
10

50
70
12

70
90
12

64
88
16

22.4
20.9
30.5
16.6*
19.1*
24.0*

25.6

30.5
27.6

31.6*

35.0
35.2*
39.9*
27.6*
27.6*
31.6*

35.0

38.2
33.4*

56.5*

5.8
5.8
5.8
7.5
7.5
7.5

7.5

7.5
7.5

7.5

84
108
16

M20
100
131
20

47.1 70.1
47.1
52.8
33.4* 71.4*
33.4*
56.5*

10.9 10.9 15.2 20.9


10.0 11.6
10.9 9.2 13.4
12.9 16.9 16.9 36.5
12.9 16.9
12.9 16.9 16.9

21.4 40.5 40.5 96.0 96.0 194.6


29.1 40.5 96.0
29.7 46.9 46.9 114.3 114.3
55
55
60
65
65
55

100

65
100

70

75
130
80
90
100
75

140

90
100

80

90
85
90
105
80
80

170

150

100

100

140

130

170

200

30

50

50

100

100

200

* steel failure
1) For min. axial spacing and min. edge distance the above described loads have to be reduced!
(See Technical Handbook or design software CC-Compufix)
All load values apply for: concrete compressive strength fc,200 = 30 N/mm2
no edge or spacing influences.
Recommended loads:
material safety factors M and safety factor for load L = 1.4 are included.
Material safety factor M depends on type of anchor.
The conditions of application differ from those given in the European Technical Approval.
For further detailed information about European Technical Approvals please contact fischer technical
service department.

33

HIGH PERFORMANCE STEEL ANCHORS

fischer Anchor bolt FA


The economical through bolt thats re-usable ideal for stadium seating

Suitability

fischerbolt FA

Suitable for:
concrete B15 and dense natural stone.

For fixing:
Railings, hand rails, seating, stock pens, gratings, supports,
consoles, machines, metal constructions, metal profiles.

Description
 For through fixing.
 Torque controlled, safe expansion.
 Highest reliability.
 Demountable fixing leaving a flush surface
 Domed nut for neat appearance
 Red knurled collar prevents turning in hole on installation
 The expansion sleeve guarantees an even, calibrated
hold and depth in all compact materials
 The reduced diameter and practical installation make it
ideal for a quick, secure job

FA zinc plated and passivated, with hexagon domed nut


do

Type
pack

Art. No.

Drill

mm

td
Min.
drill-hole
depth for
through
fixing
mm

hv
Min.
anchorage
depth
mm

da

Mc

SW

Fixing
length
mm

Max.
fixing
thickness
mm

Torque
Nm

Width
across
nut

Qty
per

25

FA 8/15

( 8 x 70)

50200

75

50

65

15

10

13

FA 8/25

( 8 x 85)

50207

90

50

80

25

10

13

25

FA 10/15

(10 x 85)

50201

10

90

60

75

15

20

17

25

FA 10/50

(10 x 120)

50208

10

120

60

110

50

20

17

25

FA 12/15

(12 x 100)

50202

12

100

70

85

15

35

19

20

FA 12/50

(12 x 135)

50212

12

135

70

120

50

35

19

20

Ultimate loads Fu, m [kN] (mean values) and recommended loads Frec

FA 14/20

(14 x 115)

50203

14

115

80

100

20

50

22

10

[kN] for a single anchor in non-cracked concrete

FA 14/50

(14 x 145)

50214

14

145

80

130

50

50

22

20

Anchor type/thread
Fu, m

Installation diagram

34

B25

FA 8
1280

FA 10
1540

FA 12
2030

FA 14
2540

Frec

B25

250

350

450

600

Axial spacing

(cm)

16

24

26

40

Edge distance

(cm)

10

13

15

Min. component thickness

(cm)

15

15

20

20

For your notes

35

HIGH PERFORMANCE STEEL ANCHORS

fischer Concrete screw FBS

NEW

Safe form fit through special thread.

Suitability

Suitable for:
Concrete B15 and masonry building materials.
For fixing of:
Installation rails, ventilation ducts, pipework,
suspended ceilings, metal profiles, wood sub-structures,
facade sub-structures, shelf feet. Also suitable for temporary
fastenings such as wall shuttering.

2
3

Panhead (P)
Countersunk head (SK)
Hexagon with
integrated washer (US)

4
5
6

Hexagon (S)
External thread (M8)
Internal thread (M8/M10)

Description

Advantages

fischer concrete screws have a specially hardened thread.


The lower turns of the thread also have teeth. The diameter
of the hole and the thread of the screw are adapted to one
another so that the special thread of the screw cuts into the
concrete. The thread turns creating a fine undercut, thereby
ensuring that the load is safely supported by a perfect form
fit. The teeth allow the thread to cut into the concrete,
thereby reducing the amount of energy required to insert the
screw into its position.

 Fast installation by simply screwing the screw into the


hole in the concrete.

Approvals
Z-21.1-1717
Z-21.1-1716
Z-21.1-1718

Concrete screw FBS 8 + 10


Concrete screw FBS 10 A4
Concrete screw FBS 5 + 6

Installation diagram

36

Fire resistance
classification

F 90/120

 Fully detachable screw attachment.


 High permissible loads through safe form fit.
 Minimum edge and axial distances through absence of
expansion pressure.
 Variable application through different head shapes.

HIGH PERFORMANCE STEEL ANCHORS

fischer Concrete screw FBS


Technical data

Type

Art. No.

Installation example

do

df

ds

Drill 
mm

Drillhole 
in
object
mm

Screw
outer 
mm

td
Min.
drill-hole
depth for
pushthrough
installation
mm

hnom

tfix

L=
hnom + t fix

Min.
Screwin
depth
mm

Max.
fixing
thickness
mm

Screw
length
mm

Drive

Qty.
per
pack

zinc plated
FBS 5/5 P

66774

6.5

65

55

60

T30

100

FBS 6/5 SK

66935

7.6

65

55

60

T30

100

FBS 6/5 P

66939

7.6

65

55

60

T30

100

FBS 6/25 P

66948

7.6

85

55

25

80

T30

100

FBS 6 M8

66949

7.6

60

55

55

SW10

100

FBS 6 M8/M10I 66950

7.6

60

55

55

SW13

100

FBS 8/5 US

66956

12

10.5

90

75

80

T40/SW13 100

FBS 8/25 US

66957

12

10.5

110

75

25

100

T40/SW13 100

FBS 8/15 S

66958

12

10.5

100

75

15

90

SW16

100

FBS 10/5 S

67062

10

14

12.5

100

85

90

SW18

50

FBS 10/15 S

67063

10

14

12.5

110

85

15

100

SW18

50

FBS 10/25 S

67168

10

14

12.5

120

85

25

110

SW18

50

10

14

12.5

105

85

10

95

SW17

50

A4 stainless steel
FBS 10/10 S A4 67169

Mean ultimate loads and recommended loads for single anchors of fischer concrete screw FBS
with large axial spacing and edge distance
Non-cracked concrete
Anchor size

Cracked concrete

FBS 8

FBS 10

FBS 5*

FBS 6*

FBS 8

FBS 10

Effective anchorage depth

heff

[mm]

50

60

55

55

50

60

Drill hole depth

ho 

[mm]

85

95

60

60

85

95

Screw-in depth

hnom 

[mm]

75

85

75

85

do

[mm]

10

10

Drill hole diameter


Mean ultimate loads Nu,m and Vu,m [kN]
Tensile

Nu,m

[kN]
[kN]

gvz
A4

21.2

26.4
26.4

1.2

3.2

10.0

16.0
16.0

Shear

90

Vu,m

[kN]
[kN]

gvz
A4

29.6

48.4
54.4

29.6

48.4
54.4

Tensile

Nrec

[kN]
[kN]

gvz
A4

5.3

6.6
6.6

0.3

0.8

2.5

4.0
4.0

Shear

90

Vrec

[kN]
[kN]

gvz
A4

7.4

12.1
13.6

7.4

12.1
13.3

Mrec

[Nm]

gvz

19.0

40.0

8.0

19.0

40.0

[Nm]

A4

36.8

36.8
60

Recommended loads Nrec and Vrec [kN]

Recommended bending moment Mrec [Nm]

Component dimensions, minimum axial spacings and edge distances


Min. axial spacing1)

smin

[mm]

50

60

50

50

50

Min. edge distance1)

cmin

[mm]

60

65

100

100

60

65

Min. structural component thickness

hmin

[mm]

120

130

110

110

120

130

* For the fixing of lightweight suspended ceiling constructions only.


1) For min. axial spacing and min. edge distance the above described loads have to be reduced! (See Technical Handbook or design software CC-Compufix)
All load values apply for: concrete compressive strength fc,200 = 30 N/mm2
no edge or spacing influences.
Recommended loads:
material safety factors M and safety factor for load L = 1.4 are included. Material safety factor M depends on type of anchor.
The conditions of application differ from those given in the German approval.
For further detailed information about German approval please contact fischer technical service department.

37

HIGH PERFORMANCE STEEL ANCHORS

fischer Sleeve anchor FSA


The economical through bolt for all applications not requiring Approvals.

Suitability
Suitable for:
Concrete B15 and natural stone with dense
structure.

1
2

Sleeve anchor FSA-S


Sleeve anchor FSA

Material: zinc plated and passivated steel.

For fixing of:


Railings, handrails, gratings, supports, consoles, machines,
metal constructions, metal profiles etc.
1

Description
The fischer Sleeve anchor FSA is a torque controlled expanding steel anchor for all through fixings for light and medium
loads.
Unlike ordinary sleeve anchors, the geometry of the expansion sleeve and the cone has been improved and the combined effect of these two functional elements optimised.
This guarantees full expansion in all cases, thus providing
optimum safety and reliability at the high level you expect of
fischer.

2
Picture for illustration purposes only

The FSA is available in 2 versions:


 FSA-S with hexagon screw and cone nut

Advantages
 The simple design and construction result in an excellent
cost-performance ratio.
 The computer optimised anchor cone and the suitably
adjusted expansion sleeve result in a safe expansion.
 The crescent-shaped punch-outs enable the sleeve to
neatly slide together on the axis when bridging hollow
layers. The assembly object braces tightly against the
building material.
 The setting depth mark allows verification of the correct
installation any time.

td
hv

da

MD
do

 The setting head at the runout of the conical bolt prevent


damage to the thread. In the case of de-mounting, an easy
thread travel is always ensured.
l

Installation diagram

38

HIGH PERFORMANCE STEEL ANCHORS

fischer Sleeve anchor FSA


Technical data
Picture for illustration purposes only

FSA zinc-plated and passivated steel, with conical bolt and hexagon nut

FSA-S zinc-plated and passivated steel, with hexagon screw and cone nut
do

td
Min.
drill-hole
depth for
through
fixing
mm

hv
Min.
anchorage
depth
mm

do

da

SW

Fixing
length
mm

Max.
fixing
thickness
mm

Thread

Width
across
nut

Qty.
per
pack

Type

Art. No.

Drill

mm

td
Min.
drill-hole
depth for
through
fixing
mm

hv
Min.
anchorage
depth
mm

da

SW

Fixing
length
mm

Max.
fixing
thickness
mm

Thread

Width
across
nut

Qty.
per
pack

Type

Art. No.

Drill

mm

FSA 8/15 S

68520

65

35

69

15

M 6

10

50

FSA 6/5

60168

35

20

25

M 4.5

100

FSA 8/40 S

68521

90

35

94

40

M 6

10

50

FSA 6/8

60156

48

30

38

M 4.5

100

FSA 8/65 S

68522

115

35

119

65

M 6

10

50

FSA 6/25

60157

68

33

58

25

M 4.5

100

FSA 10/10 S

68523

10

65

40

70

10

M 8

13

20

FSA 8/8

60158

57

34

42

M 6

10

100

FSA 10/35 S

68524

10

90

40

95

35

M 8

13

20

FSA 8/30

60150

81

36

66

30

M 6

10

100

FSA 10/60 S

68525

10

115

40

120

60

M 8

13

20

FSA 8/55

60159

107

37

92

55

M 6

10

100

FSA 12/10 S

68526

12

75

50

81

10

M10

17

20

FSA 10/10

60160

10

63

38

48

10

M 8

13

50

FSA 12/25 S

68527

12

90

50

96

25

M10

17

20

FSA 10/35

60151

10

90

40

75

35

M 8

13

50

FSA 12/50 S

68528

12

115

50

121

50

M10

17

20

FSA-A2 Stainless Steel A2, with conical bolt and hexagon nut
do

td
Min.
drill-hole
depth for
through
fixing
mm

Type

Art. No.

Drill

mm

FSA 8/45 A2

60250

60

FSA 8/65 A2

60251

FSA 10/50 A2

60252

10

FSA 10/70 A2

60253

10

hv

da

SW

Min.
anchorage
depth
mm

Fixing
length
mm

Max.
fixing
thickness
mm

Thread

Width
across
nut

Qty.
per
pack

25

45

10

M 6

10

100

80

30

65

25

M 6

10

50

65

30

50

10

M 8

13

50

85

35

70

25

M 8

13

50

FSA 10/100 A2 60254

10

115

35

100

55

M 8

13

50

FSA 10/120 A2 60255

10

135

35

120

75

M 8

13

50

FSA 12/60 A2

60256

12

80

35

60

10

M10

17

25

FSA 12/80 A2

60257

12

100

40

80

25

M10

17

25

FSA 12/100 A2 60258

12

120

40

100

45

M10

17

20

FSA 12/120 A2 60259

12

140

40

120

65

M10

17

20

FSA 10/60

60152

10

115

40

100

60

M 8

13

50

FSA 12/12

60161

12

73

46

58

12

M10

17

25

FSA 12/20

60153

12

85

50

70

20

M10

17

25

FSA 12/50

60154

12

115

50

100

50

M10

17

20
20

FSA 12/75

60162

12

140

50

125

75

M10

17

FSA 16/12

60163

16

84

52

64

12

M12

19

20

FSA 16/50

60155

16

128

58

108

50

M12

19

10

FSA 16/80

60164

16

162

62

142

80

M12

19

10

FSA 20/20

60165

20

107

62

82

20

M16

24

10

FSA 20/50

60166

20

139

64

114

50

M16

24

FSA 20/95

60167

20

183

63

158

95

M16

24

Installation examples

Mean ultimate loads and recommended loads for single


anchors of fischer Sleeve anchor FSA with large axial
spacing and edge distance
Non-cracked concrete
Anchor size

FSA 8/..
M6

Effective anchorage depth


heff
[mm]
35
Drill hole depth
ho 
[mm]
50
Drill hole diameter
do
[mm]
8
Mean ultimate loads Nu,m and Vu,m [kN]
Tensile
0
Nu,m
[kN]
gvz
12.0
Shear
90
Vu,m
[kN]
gvz
13.2*
Recommended loads Nrec and Vrec [kN]
Tensile
0
Nrec
[kN]
gvz
2.8
Shear
90
Vrec
[kN]
gvz
5.1
Recommended bending moment Mrec [Nm]
Mrec
[Nm]
gvz
5.2
Component dimensions, minimum axial spacings and edge distances
1)
Min. axial spacing
smin
[mm]
70
Min. edge distance1)
cmin
[mm]
50
Min. structural comp. thickness
hmin
[mm]
70
Required torque
Tinst
[Nm]
10

FSA 10/..
M8

FSA 12..
M 10

40
55
10

50
65
12

14.7
18.7

21.5
26.1

3.7
6.2

4.5
8.7

12.9

25.7

80
60
80
25

100
60
100
40

* steel failure
1) For min. axial spacing and min. edge distance the above described loads have to be reduced!
(See Technical Handbook or design software CC-Compufix)
All load values apply for: concrete compressive strength fc,200 = 30 N/mm2
no edge or spacing influences.
Recommended loads:
material safety factors M and safety factor for load L = 1.4 are included.
Material safety factor M depends on type of anchor.

For detailed design method please contact fischer technical service department.

39

HIGH PERFORMANCE STEEL ANCHORS

fischer Hollow-ceiling anchor FHY


Specially for fixings in hollow-ceiling slabs.

Suitability

Suitable for: Hollow-ceiling slabs of prestressed


concrete, concrete B55.

Hollow-ceiling anchor FHY

Material: zinc plated steel and A4 stainless steel

For fixing of: All types of anchoring, e.g. cross beams, pipes
and ventilation ducts, suspended ceilings, safety engineering,
cable trays.
1

Description
The fischer Hollow-ceiling anchor FHY has been developed
specially for fastenings in hollow-ceiling slabs of prestressed
concrete. It is designed for use with standard bolts or
threaded rods with metric threads from M6 to M10.
The Hollow-ceiling anchor FHY is installed flush with the
concrete surface. When the bolt or the nut is tightened a
tapered element is pulled into the sleeve, which presses this
outwards. In this way, the FHY presses against the sides of
the hole, creating a friction fit. If the anchor encounters a
cavity during installation, the expansion of the sleeve forms a
Y shape. The holding power is now the result of a
combination of expansion pressure and form-fit.
The fischer Hollow-ceiling anchor FHY offers considerable
scope in the location of attachment points. Unlike other
competing products, it does not have to be located at the
centre of the cavity axis, which is often very difficult to
define. Instead, it can be located down to a minimum
distance of 50 mm from the prestressing steel.

Installation advice
do

How to determine the length of the screw ls:

tfix

hef

(= length of the screw


(+ additional thickness of nut and washer with
threaded rods)

ls

length of the fischer Hollow-ceiling anchor FHY


(+ thickness of the building component da

Approvals
Z-21.1-1711

Approval is valid for


zinc plated steel.

Installation diagram

40

Fire resistance
classification

F 120

Tinst

HIGH PERFORMANCE STEEL ANCHORS

fischer Hollow-ceiling anchor FHY


Technical data

Installation examples

FHY zinc plated steel


do

Type

Art. No.

h1*
Min.
drillhole
depth
mm

Drill

mm

hef 1)
Min.
anchorage
depth
mm

l
Fixing
length
mm

Screw-in
depth
min. max.*
mm
mm

Thread

Qty.
per.
pack

FHY M 6

30138

10

50

30

37

M 6

37

45

50

FHY M 8

30146

12

60

35

43

M 8

43

55

25

FHY M 10

30148

16

65

40

52

M 10

52

60

20

hef 1)
Min.
anchorage
depth
mm

Thread

Screw-in
depth
min. max.*
mm
mm

FHY A4 stainless steel (Material: 1.4401)


do

Type

Art. No.

h1*
Min.
drillhole
depth
mm

Drill

mm

Fixing
length
mm

Qty.
per.
pack

FHY M 6 A4

30139

10

50

30

37

M 6

37

45

50

FHY M 8 A4

30147

12

60

35

43

M 8

43

55

25

FHY M 10 A4

30151

16

65

40

52

M 10

52

60

20

* in solid materials

Recommended loads1) fixing parameters and component dimensions for tension, shear and diagonal load at any angle in hollow-slab floors of prestressed
concrete of strength class B55 or C50/60. When dimensioning, observe
the approval Z-21.1-1711 in its entirety.
Fixing type
Web thickness

FHY M 6
du mm 25
< 30
h1 mm
mm

Drill hole depth


Drill hole diameter
Single fixing
Perm. F 2) with
c ccr1.2
Perm. F 2) with
c = cmin1.2
Axial spacing2)
ccr1.2
Min. edge distance2)
cmin1.2
Axial spacing
scr1.2
Pairs of fixings3)
Perm. F with
c ccr1.2
Perm. F with
c = cmin
Min. axial spacing
smin1.2
Edge distance
ccr1.2
Min. edge distance
cmin1.2 =
Safe working bending moment
Grade 4.6
Grade 5.8
Grade 5.8
Length of hexagon-head
min ls
screw5)
Length of threaded bolt
min lB
Installation torque
TInst
Through-hole in the component
df
to be attached

kN 0.7
kN 0.35
mm
mm
mm

FHY M 8

30 40 25
< 40
< 30
50
10
0.9
0.8

2.0
1.8

FHY M 10

30 40 30 40
< 40
< 40
60
65
12
16

0.7 0.9
0.35 0.8
150
100
300

2.0
1.8

1.2
1.0

3.0
2.7

kN 0.7 1.4 2.6 0.7 1.4 2.6


kN 0.35 1.25 2.35 0.35 1.25 2.35
mm 70
80 100 70
80 100
mm
150
mm
100

2.0
1.8
80

4.8
4.3
100

Nm
Nm
Nm
mm

4.44)
7.04)
39 + tfix

6.4
10.74)
17.14)
45 + tfix

12.8
21.44)
34.24)
54 + tfix

mm
Nm

62 + tfix
10

68 + tfix
10

77 + tfix
20

mm

12

1)

The anchorage of the Cavity Fixing FHY is permissible only in hollow-slab ceilings of prestressed concrete,
the width of whose cavities is not more than 4.2 times the web width. The fixing may also be used as
multiple fastening for anchoring lightweight ceiling coverings and underceilings to DIN 18168 on
hollow-slab ceilings of prestressed concrete, and for statically similar anchorages up to 1.0 kN/m2.
When external loads are suspended from the prestressed-concrete hollow-slab ceilings, the shearing loadbearing capacity must be reduced. For fastening lightweight ceiling coverings and underceilings,
to DIN 18168, this reduction is not necessary.
2) For edge distances c
min < cccr the permissible loads may be determined by linear interpolation.
3) The permissible load applies for a pair of fixings. The permissible load for the most highly stressed fixing must
not exceed the values stated for the single fixing.
For pairs of fixings with min axial distances of smin1.2 < s1.2 < scr1.2 the permissible load may be interpolated
linearly. The linear value at s1.2 = scr1.2 for the pair of fixings with tensile load applied, may be assumed to be
twice the permissible load for the single fixing.
4) Only threaded rods marked in accordance with the approval may be used.
5) With hexagon bolts with shaft to DIN EN 24014, the shaft length must be t .
fix

41

HIGH PERFORMANCE STEEL ANCHORS

fischer Wallbolt GM
The economical heavy-duty anchor

Suitability

GM S wallbolt - shield only

Suitable for:

GM H wallbolt - hook bolt type

Concrete B15 and natural stone with dense


structure.

GM P wallbolt - projecting bolt type

GM L wallbolt - loose bolt type

GM E wallbolt - eye bolt type

For fixing of:


Installation rails, ventilation ducts, pipework, suspended
ceilings, metal profiles, shelf feet. Also suitable for temporary
fastenings such as wall shuttering

Description

The segmented malleable iron expansion shield is


assembled ready for use with bolts or threaded rods of the
appropriate diameter.

 Function - torque controlled friction locking expansion.


 Four piece malleable shield for even load spread.
 Unique metal spring clip for retaining the segments and
the wedge.

 Traditional fixing method with wide user acceptance.


4

 Zinc plated and passivated for corrosion protection.


For the best results with the GM anchor remember to:
 Choose the most suitable accessory.
 Choose the right sized anchor in relation to load type.
 Check load bearing capacity values in the table.
 Make sure the drilled hole is dust free.

Installation diagram

42

HIGH PERFORMANCE STEEL ANCHORS

fischer Wallbolt GM
Technical data

Technical data

GM L zinc plated and passivated

GM S zinc plated and passivated

do

td

hv

Art. No.

Drill

mm

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

GM 6/10 L

58001

12

60

47

GM 6/25 L

58002

12

60

47

GM 6/40 L

58003

12

60

47

GM 8/10 L

58004

15

70

50

Type

Bolt

mm

Fixing
Thickness
mm
min max

Torque
Nm

Qty.
per
box

0 10

10

50

0 25

10

50

0 40

10

50

0 10

25

50

GM 8/25 L

58005

15

70

50

0 25

25

50

GM 8/40 L

58006

15

70

50

0 40

25

50

GM 10/10 L

58007

18

80

60

10

0 10

40

50

GM 10/25 L

58008

18

80

60

10

0 25

40

50

GM 10/50 L

58009

18

80

60

10

0 50

40

50

GM 10/75 L

58010

18

80

60

10

25 75

40

25

GM 12/10 L

58011

22

100

75

12

0 10

75

25

GM 12/25 L

58012

22

100

75

12

0 25

75

25

GM 12/50 L

58013

22

100

75

12

0 50

75

25

GM 12/75 L

58014

22

100

75

12

25 75

75

25

GM 16/15 L

58015

29

130

102

16

0 15

180

10

GM 16/30 L

58016

29

130

102

16

0 30

180

10

GM 16/60 L

58017

29

130

102

16

25 60

180

10

GM 20/60 L

58018

36

170

135

20

20 60

345

10

GM 20/100 L

58019

36

170

135

20

60 100

345

10

GM 24/100 L

58021

42

210

165

24

20 100

345

10

GM 24/150 L

58022

42

210

165

24

60 150

345

10

Type

Art. No.

do

td

hv

Drill

mm

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

Bolt

mm

Qty.
per
box

Torque
Nm

GM 6 S

58060

12

60

47

10

50

GM 8 S

58061

15

70

50

25

50

GM 10 S

58062

18

80

60

10

40

25

GM 12 S

58063

22

100

75

12

75

20

GM 16 S

58064

29

130

102

16

180

10

GM 20 S

58065

36

170

135

20

345

GM 24 S

58066

42

210

165

24

345

Bolt

mm

Eye

mm

GM E zinc plated and passivated


do

td

hv

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

Type

Art. No.

Drill

mm

Torque
Nm

Qty.
per
box

GM 6 E

58050

12

60

47

GM 8 E

58051

15

70

50

10.5

10

50

11

25

GM 10 E

58052

18

80

60

50

10

12.5

40

25

GM 12 E

58053

22

100

GM 16 E

58054

29

130

75

12

15.5

75

15

102

16

25

180

10

Bolt

mm

Hook
mm

Torque
Nm

Qty.
per
box

50

GM P zinc plated and passivated


do

td

hv

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

GM H zinc plated and passivated


Bolt

mm

Fixing
Thickness
mm
min max

do

td

hv

Torque
Nm

Qty.
per
box

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

Type

Art. No.

Drill

mm

GM 6/10 P

58030

12

60

47

0 10

10

50

GM 6/25 P

58031

12

60

47

0 25

10

50

Type

Art. No.

Drill

mm

GM 6/60 P

58032

12

60

47

0 60

10

50

GM 6 H

58055

12

60

47

7.5

10

GM 8/10 P

58033

15

70

50

0 10

25

50

GM 8 H

58056

14

70

50

10.5

25

50

GM 8/25 P

58034

15

70

50

0 25

25

50

GM 10 H

58057

16

80

60

10

13

40

25

GM 8/60 P

58035

15

70

50

0 60

25

50

GM 12 H

58058

20

100

75

12

15.5

75

15

GM 10/15 P

58036

18

80

60

10

0 15

40

50

GM 16 H

58059

29

130

102

16

21.5

100

10

GM 10/30 P

58037

18

80

60

10

0 30

40

25

GM 10/60 P

58038

18

80

60

10

0 60

40

25

GM 12/15 P

58039

22

100

75

12

0 15

75

20

GM 12/35 P

58040

22

100

75

12

0 35

75

20

GM 12/75 P

58041

22

100

75

12

0 75

75

20

GM 16/15 P

58042

29

130

102

16

0 15

180

10

GM 16/35 P

58043

29

130

102

16

0 35

180

10

Anchor type
Bolts cl. 8.8

Recommended loads [kN]


Loads in concrete cl.fc = 25 Nm/mm2 - kN
GM 6
4.00

GM 8
4.65

GM 10
5.90

GM 12
8.40

GM 16
13.40

GM 20
20.65

GM 16/75 P

58044

29

130

102

16

0 75

180

10

Eyebolt

3.20

4.65

5.90

8.40

13.40

GM 20/15 P

58045

36

170

135

20

0 15

345

Hook

0.90

1.30

1.90

3.30

2.90

GM 20/30 P

58046

36

170

135

20

0 30

345

GM 20/100 P

58047

36

170

135

20

0 100

345

GM 24/75 P

58048

42

210

165

24

0 30

345

GM 24/120 P

58049

42

210

165

24

0 100

345

Critical edge distance and critical spacing [mm]


Crit. axial spacing a
140
170
Crit. edge distance ar
40
105
Min. axial sp.a min.
80
80
Min. edge dist.armin.
50
50
Min. struct. thickness t
100
100

200
120
100
65
100

250
150
125
80
125

315
200
170
105
175

400
260
230
140
230

43

HIGH PERFORMANCE STEEL ANCHORS

fischer Wallbolt FWB


The economical heavy-duty anchor

Suitability

FWB S wallbolt - shield only

Suitable for:
Concrete B15 and natural stone with dense
structure.

FWB L wallbolt - loose bolt type

FWB P wallbolt - projecting bolt type

For fixing of:


Installation rails, ventilation ducts, pipework, suspended
ceilings, metal profiles, shelf feet. Also suitable for temporary
fixings such as wall shuttering

FWB H wallbolt - hook bolt type

FWB E wallbolt - eye bolt type

Description

The segmented steel expander shield is assembled ready


for use with bolts or threaded rods of the appropriate
diameter.
 Function - torque controlled friction locking expansion.

 Three piece shield for even load spread.


 Traditional fixing method with wide user acceptance.

 Zinc plated and passivated for corrosive protection.


The versatile heavy-duty fixing !

Installation instructions
Determination of the screw length l s:
length of the fischer Heavy-duty anchor FWB +
thickness of the building component da
= length of the screw
(in the case of threaded bolts additionally include
+ thickness of washer and nut)

Installation diagram

44

HIGH PERFORMANCE STEEL ANCHORS

fischer Wallbolt FWB


Technical data

Technical data

FWB L zinc plated and passivated

Type

Art. No.

FWB S zinc plated and passivated

do

td

hv

Drill

mm

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

Bolt

mm

Fixing
Thickness
mm
min max

Torque
Nm

Qty.
per
box

58050

12

50

45

FWB 8 S

58051

14

55

50

FWB 10 S

58052

16

65

60

FWB 12 S

58053

20

85

75

12

75

25

FWB 16 S

58054

25

130

115

16

180

10

FWB 20 S

58055

32

150

130

20

345

10

50

45

0 10

10

50

12

50

45

0 25

10

50

FWB 6/40 L

58158

12

50

45

0 40

10

50

FWB 8/10 L

58159

14

55

50

0 10

25

50

FWB 8/25 L

58160

14

55

50

0 25

25

50

FWB 8/40 L

58161

14

55

50

0 40

25

50

FWB 10/10 L

58162

16

65

60

10

0 10

40

50

FWB 10/25 L

58163

16

65

60

10

0 25

40

50

FWB 10/50 L

58164

16

65

60

10

0 50

40

50

FWB 10/75 L

58165

16

65

60

10

25 75

40

25

FWB 12/10 L

58166

20

85

75

12

0 10

75

25

FWB 12/25 L

58167

20

85

75

12

0 25

75

25

FWB 12/40 L

58168

20

85

75

12

0 50

75

25

FWB 12/60 L

58169

20

85

75

12

25 75

75

25

FWB 16/15 L

58170

25

130

115

16

0 15

180

10

FWB 16/30 L

58171

25

130

115

16

0 30

180

10

Type

FWB 16/60 L

58172

25

130

115

16

25 60

180

10

FWB 20/60 L

58173

32

150

130

20

20 60

345

10

FWB 20/100 L 58174

32

150

130

20

60 100

345

10

Type

Art. No.

Drill

mm

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

Min.
anchorage
depth
mm

FWB 6 S

12

58157

hv

Min.
drill-hole
depth
mm

Art. No.

58156

td

hv

Type

FWB 6/10 L

do

td

Drill

mm

FWB 6/25 L

FWB P zinc plated and passivated

do

Bolt

mm

Torque
Nm

Qty.
per
box

10

50

25

50

10

40

50

FWB E zinc plated and passivated


do

td

hv

Art. No.

Drill

mm

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

FWB 6 E

58193

12

50

FWB 8 E

58194

14

55

FWB 10 E

58195

16

65

FWB 12 E

58196

20

85

75

12

17

75

25

FWB 16 E

58197

25

130

115

16

23

180

10

Bolt

mm

Hook
mm

Torque
Nm

Qty.
per
box

Bolt

mm

Eye

mm

Torque
Nm

Qty.
per
box

45

10

10

50

50

12

25

50

60

10

14

40

25

FWB H zinc plated and passivated

Bolt

mm

Fixing
Thickness
mm
min max

Torque
Nm

Qty.
per
box

FWB 6/10 P

58175

12

50

45

0 10

10

50

FWB 6/25 P

58176

12

50

45

0 25

10

50

FWB 6/60 P

58177

12

50

45

0 60

10

50

FWB 8/10 P

58178

14

55

50

0 10

25

50

FWB 8/25 P

58179

14

55

50

0 25

25

50

FWB 8/60 P

58180

14

55

50

0 60

25

25

FWB 10/15 P

58181

16

65

60

10

0 15

40

50

FWB 10/30 P

58182

16

65

60

10

0 30

40

25

FWB 10/60 P

58183

16

65

60

10

0 60

40

25

FWB 12/15 P

58184

20

85

75

12

0 15

75

25

FWB 12/35 P

58185

20

85

75

12

0 35

75

25

FWB 12/75 P

58186

20

85

75

12

0 75

75

25

FWB 16/15 P

58187

25

130

115

16

0 15

180

10

FWB 16/35 P

58188

25

130

115

16

0 35

180

10

FWB 16/75 P

58189

25

130

115

16

0 75

180

10

FWB 20/15 P

58190

32

150

130

20

0 15

345

10

FWB 20/30 P

58191

32

150

130

20

0 30

345

10

FWB 20/100 P 58192

32

150

130

20

0 100

345

10

Type

Art. No.

do

td

hv

Drill

mm

Min.
drill-hole
depth
mm

Min.
anchorage
depth
mm

FWB 6 H

58198

12

50

45

10

50

FWB 8 H

58199

14

55

50

10

25

50

FWB 10 H

58200

16

65

60

10

12

40

25

FWB 12 H

58201

20

85

75

12

16

75

25

Recommended loads [kN]


For information relating to loads please contact the fischer technical
department. 01491 827920

45

HIGH PERFORMANCE STEEL ANCHORS

fischer Hammerset anchor EA


The simple hammerset anchor with internal thread.

Suitability

Hammerset anchor EA

Suitable for: Concrete B15

Material: zinc plated and passivated steel, A4 stainless steel.

For fixing of:


Flat steel, profiled steel, pipelines, suspended ceilings,
ventilation pipes, sprinkler systems, threaded rods, assembly
support, gratings, facades, diamond drilling devices (EA-D),
etc.

Description

Installation advice

The fischer Hammerset anchor EA is a compact internally


threaded fixing for attachment assembly, made of zinc
plated steel for metric threads M 6 to M 20. The sizes M 6 to
M 16 are also available in stainless steel. It is universally
easy to use and offers the following:

 It is essential to adhere to the drill-hole depth and drill


diameter.
 The cone must only be driven with the setting tool EAWH
(narrow-end) into the anchor sleeve.
 The cone must be driven into the anchor sleeve until the
tool collar lies on the anchor body.

 Economical fixing
 Shallow drill-hole depth
 displacement controlled impact expansion

The screw length must be carefully determined:

 favourable ratio of thread/drill-hole diameter


The fischer Hammerset anchor EA forms a flush seal with
the concrete surface and permits replacement of the mounted item without influencing the expansion force. The setting
method of tapping in and price/performance ratio have
made the EA anchor a standard metal fixing most acoustics
installers, heating, ventilation and sanitary equipment
installers, metal constructors and fitters

min. screw-in depth


+ thickness of the building component
= screw length
(with threaded bolt, include thickness of washer and nut)
If the screw is too long:
No tighteneing of the fixing is possible, since screw reaches
end of thread.
If the screw is too short:
Thread load-bearing capacity too low.

Approvals
Z-21.1-1619

da

t = hv
Approved for the tension
zone, light suspended
ceilings and ceiling
covers.

MD
do

Recognised for
use with fixed water
sprinkler systems
from M8.

e
ls

Dossier NPO.021

From thread M10

Installation diagram

46

EA M 8 x 40
M 10, M 12

Fire resistance
classification

F 120

= da + e

HIGH PERFORMANCE STEEL ANCHORS

fischer Hammerset anchor EA


Technical data

Installation examples

EA zinc plated and passivated steel


not suitable for diamond drilling devices and diamond saws
do

Type

Art. No.

Drill 
mm

t
Min.
drill-hole
depth
mm

EA M 61)
EA M 8
EA M 8 x 40
EA M 10
EA M 12
EA M 16
EA M 20

60811
60812
60821
60813
60814
60816
60818

8
10
10
12
15
20
25

25
30
40
40
50
65
80

hv
Min.
anchorage
depth
mm

Fixing
lenght
mm

Thread

Screw-in depth
min.
max.
mm
mm

Quantity
per pack

25
30
40
40
50
65
80

25
30
40
40
50
65
80

M 6
M 8
M 8
M 10
M 12
M 16
M 20

6
8
8
10
12
16
20

100
100
50
50
25
20
10

12
13
20
17
22
27
34

EA A4 stainless steel (material: 1.4401),


not suitable for diamond drilling devices and diamond saws
EA M 6 A41)
EA M 8 A41)
EA M 10 A4
EA M 12 A4
EA M 16 A4

60825
60826
60827
60828
60829

8
10
12
15
20

25
30
40
50
65

25
30
40
50
65

25
30
40
50
65

M 6
M 8
M 10
M 12
M 16

6
8
10
12
16

12
13
17
22
27

100
100
50
25
20

1) only part of the approval for light suspended ceilings . . .

Hammerset tools
EAW H 6
EAW H 8
EAW H 8 x 40
EAW H 10
EAW H 12
EAW H 16
EAW H 20

60836
60837
60846
60838
60839
60841
60843

Fits EA M 6
Fits EA M 8
Fits EA M 8 x 40
Fits EA M 10
Fits EA M 12
Fits EA M 16
Fits EA M 20

1
1
1
1
1
1
1

Mean ultimate loads and recommended loads for single anchors of fischer Hammerset anchor EA with large axial
spacing and edge distance
Cracked concrete1)

Non-cracked concrete
Anchor size
Effective anchorage depth
Drill hole depth
Drill hole diameter
Mean ultimate loads Nu,m and Vu,m [kN]
Tensile
0

heff
h1 =
do

[mm]
[mm]
[mm]

Nu,m

Shear

Vu,m

[kN]
[kN]
[kN]
[kN]

90

Recommended loads Nrec and Vrec [kN]


Tensile
0

Nrec

gvz
A4
gvz
A4

M6

M8

M8 x 40

M10

M12

M16

M20

M6

M8

M8 x 40

M10

M12

25
27
8

30
33
10

40
43
10

40
44
12

50
54
15

65
71
20

80
86
25

25
27
8

30
33
10

40
43
10

40
44
12

50
54
15

10.1*
12.0
6.0*
8.1*

14.0
14.0
10.2*
9.8*

16.3

10.2*

18.6
18.6
11.7*
12.4*

32.0
32.0
21.2*
22.5*

40.0
40.0
31.4*
36.8*

66.0

50.3*

6.5
6.5
10.2
8.8

9.5
9.5
12.4
14.4

13.0

20.0

0.5
0.5

0.5
0.5

0.8
0.8

0.8
0.8

0.8
0.8

28.1
42.1

71.4
107

139

140
150
150
35

170
220
200
60

200
240
240
120

400
100
100
2

400
100
100
3

400
100
100
3

400
200
100
6

400
200
100
15

[kN]
gvz
2.3
3.0
4.0
4.5
[kN]
A4
2.3
3.0

4.5
Shear
90
Vrec
[kN]
gvz
2.9
4.8
4.8
5.6
[kN]
A4
3.2
3.9

4.8
Recommended bending moment Mrec [Nm], values apply to screws with a strength classification 5.6 and A4-70 respectively
Mrec
[Nm]
gvz
3.3
8.0
8.0
16.0
[Nm]
A4
4.9
12.1
12.1
24.1
Component dimensions, minimum axial spacings and edge distances
Min. axial spacing2)
smin
[mm]
70
80
100
100
Min. edge distance2)
cmin
[mm]
80
90
120
120
Min. structural component thickness
hmin
[mm]
100
100
120
120
Required torque
Tinst
[Nm]
4
8
8
15

* steel failure, values apply to screws with a strength classification 5.6 and A4-70 respectively.
1) For the fixing of lightweight suspended ceiling constructions only.
2) For min. axial spacing and min. edge distance the above described loads have to be reduced! (See Technical Handbook or design software CC-Compufix)
All load values apply for: concrete compressive strength fc,200 = 30 N/mm2
no edge or spacing influences.
Recommended loads:
material safety factors M and safety factor for load L = 1.4 are included. Material safety factor M depends on type of anchor.

The conditions of application differ from those given in the German approval.
For further detailed information about German approval please contact fischer technical service department.

47

HIGH PERFORMANCE STEEL ANCHORS

HIGH PERFORMANCE STEEL ANCHORS

fischer Drop-in Anchor


with Rim. FDA-R

fischer Ceiling anchor


FDN

Drop-in anchor with rim

Ceiling anchor

Suitability

Suitability

Suitable for:
Concrete B15 and dense natural stone plus hollow core
slabs

Suitable for:
Concrete B15 and dense natural stone

For fixing of:


ideal for fastening with bolts or threaded rods for plumbing,
air-conditioning, heating and ventilation installations.
Available in zinc plated.

For fixing of:


ideal for fastening suspended ceiling wires or brackets.

Description
A ceiling anchor for rapid installation, with high retaining
power. The wedge shaped segments move over each other
during insertion, wedging the nail in the hole.

Description
A drop-in anchor with rim so that the anchor always remains
flush with the surface of the substrate. The drill hole can
now be overdepth without effecting the anchor

Technical data

Technical data
do

td
Min.

Drill 
mm

depth for
through fixing
mm

Fixing
length
mm

do

drill-hole

.
Fixing
length
mm

Type

Art. No.

Drill 
mm

25

100

FDN 6/35

78644

40

35.0

100

30

100

FDN 6/65

78645

40

35.0

100

Art. No.

FDA-R 6x25

62366

27

FDA-R 8x30

62378

10

32

FDA-R 10x30

62379

12

33

30

100

Mean ultimate loads in kN.


Use 80% of EA loads, see page 47.

A rim for the accurate


setting of the anchor
flush to the surface, not
dependant on hole depth.

48

Quantity
per pack

Type

Installation diagram

td
Min.
drill-hole
depth for
through fixing
mm

Quantity
per pack

Mean ultimate loads in kN.


An appropriate safety coefficient must be allowed on these
breaking values (see page 16).
Anchoring base

FDN

Concrete B 25

0.5

HIGH PERFORMANCE STEEL ANCHORS

fischer Nail Sleeve FNH


The fast and simple fastening made of dacromet-coated sprung steel.

Suitability

Suitable for:
Concrete B25, solid brick, pressure-resistant
natural stone, lightweight building materials.

Nail Sleeve FNH

For fixing of:


Board sub-structures, metal sheets and profiles, small items
in building interiors

Installation example

Description
The FNH nail sleeve is a fast and economical fastening made
of dacromet-coated sprung steel. Especially suitable for
small items in building interiors.
When pushed through the object being installed, the sleeve
expands over its entire length in the hole. Simple and timesaving. The object is held by its collar. No screws required.

do

Technical data
h ef
do

td
Min.
drill-hole
depth for
through
fixing
mm

tfix
td

hef

tfix

Effect.
anchorage
depth
mm

Fixing
length
mm

Max.
fixing
thickness
mm

Qty.
per
pack

Type

Art. no.

Drill 
mm

FNH 5/50

50192

30

20

50

30

100

FNH 6/30

19863

40

30

30

100

FNH 6/40

50638

50

30

40

10

100

FNH 6/50

77525

60

30

50

20

100

Fixing type

FNH 6/60

19864

70

30

60

30

100

Effective anchorage depth

FNH 6/80

19865

90

30

80

50

100

Drill hole depth

FNH 8/70

19866

80

40

70

30

100

Drill hole diameter

FNH 8/90

19867

100

40

90

50

50

Recommended loads for single anchors of


fischer Nail sleeve FNH in kN
Non-cracked concrete
FNH 5

FNH 6

FNH 8

hef

[mm]

20

30

40

h1 

[mm]

30

40

50

[mm]

Tensile B25

do
Nrec

[kN]

0.20

0.55

1.10

hmin

[mm]

50

60

70

FNH 8/110

19868

120

40

110

70

50

Min. component thickness

FNH 8/130

19869

140

40

130

90

50

FNH 8/150

19870

160

40

150

110

50

Recommended loads: material safety factors M and safety factor for load L = 1.4 are
included. Material safety factor M depends on type of anchor.

Installation diagram

49

HIGH PERFORMANCE STEEL ANCHORS

fischer Nail anchor FNA


For hammerset installation in concrete.

Suitability

Suitable for: Concrete B15.

For fixing of:


Laths, squared timber beams, battens, wood substructures,
metal profiles, chains, cables, punched tapes, wire hangers,
extension nuts with threaded rods, fire partitions, ventilation
pipes, suspended ceilings, C-rails, ceiling insulation on light
wood-wool boards, etc.

Description

FNA
FNA
FNA
FNA
FNA

with nail head


with M6 + M8 thread
with eye
with hook
for rail fixing

Material: zinc plated and passivated steel, A4 stainless steel and high
corrosion resistant steel 1.4529 - see page 52/53.
1

The fischer Nail Anchor can be installed swiftly and


smoothly, a real advantage for overhead work.
 Low drilling expenditure, only 6 mm diameter.

 Easy tap-in assembly, two hammer blows are sufficient.


 All building site requirements are available.
 Building inspectorate approval for more safety.

Advantages
FNA with nail head:
For battens and metal hangers. The nail head can be effortlessly sunk into timber with one blow. On metal parts, it
covers a large surface area, giving a clean finish. Longer
useful lengths bridge non-load-bearing layers.

Enables quick and easy installation of lightweight railing.


FNA with M 6 + M 8 thread:
For all demountable connections with metric thread. Connection of threaded hanger rods is possible by means of
extension couplers. Longer threaded portion enables bridging
of non-load bearing layers such as plaster or insulation.
FNA with eye:
For anchoring of hangers, punched tapes, cables or chains.
FNA with hook*:
For suspending chains, lamps, cable loops, rings or other
closed parts.
FNA for rail fixing:

Approvals
Z-21.1-606

Approved for the


tension zone, light
suspended ceilings
and ceiling covers.

Installation diagram

50

Stainless
steel
1.4529

see page 52-53

Fire resistance
classification

F 60/90/120

*Not an element of the building inspectorate approval.

HIGH PERFORMANCE STEEL ANCHORS

fischer Nail anchor FNA


Technical data

Installation examples
with nail head  15 mm
do

td
Min.
drill-hole
depth for
through
fixing mm

hv
Min.
anchorage
depth
mm

l
Fixing
length
mm

da
Max.
fixing
thickness
mm

SW

Type

Steel
gvz.
Art. No.

Steel
A4
Art. No.

Drill

mm

Width
across
Thread nut

Qty.
per
pack

FNA 6 x 30/ 5

50938

77802*

50

30

45

100

FNA 6 x 30/ 30

50940

77805*

75

30

71

30

50

FNA 6 x 30/ 50

50942

95

30

91

50

50

FNA 6 x 30/ 75

50941

115

30

111

75

50

FNA 6 x 30/100

50943

150

30

145

100

50

FNA 6 x 30/120

50944

170

30

165

120

50

FNA 6 x 40/ 5

50936

60

40

55

50

* not included in building inspectorate approval


with thread M 6 and M 8
FNA 6 x 30 M 6/5**50920

77806*

FNA 6 x 40 M 8/5**50951

50

30

52

M 6 10

100

55

40

55

M 8 13

50

* not included in building inspectorate approval ** max. installation torque = 4 Nm.

with eye  10 mm
FNA 6 x 30 OE

50922

45

30

64

50

30

64

50

40

55

with hook  10 mm
FNA 6 x 30 H*

50921

45

* not included in building inspectorate approval

for rail fixing


FNA 6 x 40 S*

50947

60

50

* not included in building inspectorate approval

Mean ultimate loads and recommended loads for single


anchors of fischer Nail anchor FNA with large axial
spacing and edge distance
Non-cracked concrete
Anchor size

Effective anchorage depth


Drill hole depth
Drill hole diameter
Mean ultimate loads Nu,m [kN]
Tensile2)
Shear2)
Recommended loads Nrec [kN]
Tensile2)

heff [mm]
ho  [mm]
do
[mm]
Nu,m
Nu,m
Vu,m
Vu,m

[kN]
[kN]
[kN]
[kN]

gvz
A4
gvz
A4

FNA
6x40
M 8/5

FNA
6x30
6x40

FNA
6x40
M 8/5

30
45
6

40
55
6

30
45
6

40
55
6

5.0*
5.6*
3.0
6.3

5.0*

9.8*

2.4

5.1

0.5
0.5
1.0
1.0

0.8

1.6

120
80
100
4

60
50
100
4

80
60
100
4

Nrec [kN]
gvz
2.1
Nrec [kN]
A4
2,1
Vrec [kN]
gvz
1.7
Vrec [kN]
A4
2.9
Component dimensions, minimum axial spacings and edge distances
Min. axial spacing3)
smin [mm]
100
Min. edge distance3)
cmin [mm]
60
Min. structural comp. thickness
hmin [mm]
100
Required torque
Tinst [Nm]
4
Shear2)

Cracked concrete1)

FNA
6x30
6x40

* steel failure decisive


1) For the fixing of lightweight suspended ceiling constructions only.
2) Loads are not valid for the anchor type FNA with hook.
3) For min. axial spacing and min. edge distance the above described loads have to be reduced!
(See Technical Handbook or design software CC-Compufix)
All load values apply for: concrete compressive strength fc,200 = 30 N/mm2
no edge or spacing influences.
Recommended loads:
material safety factors M and safety factor for load L = 1.4 are included.
Material safety factor M depends on type of anchor.

The condition of application differ from those given in the German


approval.
For detailed design method and design in accordance with German
approval please contact fischer technical service department.

51

HIGH PERFORMANCE STEEL ANCHORS

Anchors made of highly corrosion-resistant steel


Material 1.4529

Suitability

1
2

Suitable for:
Concrete B15.

3
4

For fixing of:


Ventilation systems, pipelines, cable trays in road tunnels,
installations and suspended ceilings in indoor swimming
pools, steel structures and other mountings in bridge areas
as well as in the chemical industry etc.

5
6
7

fischer
fischer
fischer
fischer
fischer
fischer
fischer

Zykon anchors FZA C


Zykon hammerset anchors FZEA C
Threaded rods RG M C
Threaded rods FIS G C
Highbond anchor FHB-A C
Nail anchor FNA C
Anchor Bolt FAZ - C

from version 5.0

Description

 In atmospheres with high chloride, sulphur-dioxide and


humidity contents, the risk of corrosion is high due to the
concentration of contaminants.

 For safe and durable fixing, fischer now offers steel


anchors which are able to withstand especially corrosive
environmental conditions.

 These new fastening elements are made of high-alloy


steel with material number 1.4529.

 In material approval Z-30.3-6, this highly corrosion-resistant


steel has the highest resistance classification of IV.

Advantages
 Fast and safe anchoring is now possible in areas which
were not previously included in the approval. The various
areas of application are regulated in the approval thereby
allowing maximum planning safety even in critical cases.
 With the FZA Zykon Anchor, the FZEA Zykon Hammerset
Anchor, the FHB Highbond Anchor and the FNA Nail
Anchor, fischer now offers fixing elements of material
1.4529 which are suitable for use in the tension zone.
 The right anchor for every fixing task. Whether as bolt,
push-through, interior-thread or synthetic-resin anchor,
fischer has the right fixing for your purpose.

Approvals
Z-21.1-958

FZA

FZEA

Z-21.3-1615

R + ETA option 8

Z-21.3-1707

Stainless
steel
1.4529

FHB

FAZ

52

FNA

 In long years of research, fischer has accumulated an


unequalled expertise in this field which we are happy to
pass on to our customers. Just contact our field
engineers.
 We manufacture job-specific products to your
requirements. This guarantees you maximum flexibility,
even with special dimensions.

HIGH PERFORMANCE STEEL ANCHORS

Anchors made of highly corrosion-resistant steel


Technical data

Technical data

Highbond anchor FHB-A C


Zykon anchor FZA C
Highly corrosion-resistant stainless steel (material: 1.4529)

Material 1.4529
See page 21 Tools.

Stainless
steel
1.4529

Effect.
anchorage
depth
mm

do

ho

Max.
fixing
thickness
mm
Thread

Width
across
nut

Qty.
per
pack

Type

Art. No.

Drill 
mm

da

SW

Drillhole
depth
mm

hef
Effect.
anchorage
depth
mm

Fixing
thickness
mm

Thread

Hexagon
nut

Required
resin

Qty.
per
set

Type

Art. No.

Drill 
mm

FHB-A 10 x 60/10 C

62401

12

65

60

10

10

17

10

FZA 10 x 40 M 6/10 C*

96214

10

40

10

M 6

10

25

FHB-A 10 x 60/60 C

62402

12

65

60

60

10

17

10

FZA 10 x 40 M 6/35 C

96361

10

40

35

M 6

10

25

FHB-A 12 x 80/10 C

62403

14

85

80

10

12

19

10

FZA 12 x 40 M 8/15 C

96215

12

40

15

M 8

13

25

FHB-A 12 x 80/60 C

62404

14

85

80

60

12

19

10

FZA 14 x 40 M 10/25 C

96228

14

40

25

M 10

17

25

FHB-A 12 x 100/25 C

62405

14

105

100

25

12

19

10

FZA 12 x 50 M 8/15 C*

96227

12

50

15

M 8

13

20

FHB-A 12 x 100/60 C

62406

14

105

100

60

12

19

10

FZA 12 x 50 M 8/50 C

96362

12

50

50

M 8

13

20

FHB-A 16 x 125/30 C

62408

18

130

125

30

16

24

10

FZA 14 x 60 M 10/25 C*

96216

14

60

25

M 10

17

10

FHB-A 16 x 125/60 C

62407

18

130

125

60

16

24

10

FZA 14 x 60 M 10/50 C

96358

14

60

50

M 10

17

10

FHB-A 20 x 170/50 C

62409

24

175

170

50

20

30

10

FZA 18 x 80 M 12/25 C*

96315

18

80

25

M 12

19

10

FHB-A 24 x 220/50 C

62418

28

225

220

50

24

36

FZA 18 x 80 M 12/55 C

96359

18

80

55

M 12

19

10
10

* For the correct resins FIS HB 345 S and FIS HB 150 C, see page 2.
Prices, delivery times and other dimensions available on request.

FZA 22 x 100 M 16/60 C

96364

22

100

60

M 16

24

FZA 22 x 125 M 16/60 C

96360

22

125

60

M 16

24

FZA 12 x 50 M 8 D/10 C

96319

12

40

10

M 8

13

25

FZA 12 x 60 M 8 D/10 C

96353

12

50

10

M 8

13

25

FZA 12 x 80 M 8 D/30 C

96354

12

50

30

M 8

13

25

FZA 14 x 80 M 10 D/20 C

96355

14

60

20

M 10

17

10

FZA 18 x 100 M 12 D/20 C

96356

18

80

20

M 12

19

10

FZA 18 x 130 M 12 D/50 C

96357

18

80

50

M 12

19

10

* Article available from stock.


Prices, delivery times and other dimensions available on request.
Hammerset anchor FZEA C

Material 1.4529
See page 25, Tools

Nail anchor FNA

With nail head  15 mm

with thread M 6 and M 8


do

Type

Art. No.

Drill 
mm

td
Min. drillhole depth
for through
fixing
mm

hv
Min.
anchorage
depth
mm

l
Fixing
length
mm

da
Max.
fixing
thickness
mm

SW

Thread

Width
across
nut

Qty.
per.
pack

FNA 6 x 30/5 C*

77807

50

30

45

FNA 6 x 30/30 C*

77808

75

30

71

30

100
50

FNA 6 x 30 M 6/5 C* 77809

50

30

52

M6

10

100

* Approval pending

Drill 
mm

Anchorage
depth
mm

Internal
thread

Screw-in
depth mm
min.
max.

Qty.
per
pack

Type

Art. No.

FZEA 10 x 40 M 8 C*

96236

10

40

M 8

11

17

100

FZEA 12 x 40 M 10 C*

96237

12

40

M 10

13

19

100

FZEA 14 x 40 M 12 C*

96238

14

40

M 12

15

21

50

Installation examples

* Article available from stock.


Prices, delivery times and other dimensions available on request.
Resin anchor threaded rod RG M C

Material 1.4529

Stainless
steel
1.4529

Available with glass capsule RM or injection resin FIS V, both with ETA
approval - see page 13

Type

Art. No.

Drill 
mm

Min.
drillhole
depth
mm

Min.
anchorage
depth
mm

Max.
fixing
thickness
mm

Fits resin
capsule

SW
(Width
across)
hexagon
nut

Qty.
per
pack

RG M 8 x 110 C*

96316

10

80

80

13

50270

13

10

RG M 10 x 130 C*

96217

12

90

90

20

50271

17

10

RG M 12 x 160 C*

96218

14

110

110

25

50272

19

10

RG M 16 x 190 C*

96219

18

125

125

35

50273

24

10

* Article available from stock.


Prices, delivery times and other dimensions available on request.

fischer Anchor bolt FAZ

Information on this product range and sizes was not available at time of printing. For further
details please contact fischer customer services 01491 827900

53