Capping Cylindrical Concrete Specimens with Sulfur or Capping Compound
ASTM Designation: ASTM C617
Purpose: To cap hardened Portland cement concrete cylinders and drilled concrete cores with sulfur mortar or other capping compounds to prepare the specimen for compressive strength testing Significance and Use: this procedure provides plane surfaces perpendicular to the specimen axis on the ends of concrete cylinders before performing the compression test. Equipment: 1. Alignment device consisting of a frame with guide bars and a cup. The size of the alignment device should match the specimen size. 2. Melting pot, used for melting sulfur mortars or capping compound, equipped with automatic temperature control. The melting pot should be used either outdoors or under an exhaust hood. Heating over an open flame is dangerous, because the mixture may ignite if overheated. Capping Procedure 1. Prepare the sulfur mortar or capping compound by heating to about 130 oC. Use a metal thermometer to check the temperature. Make sure to empty any old mortar and to use fresh mortar to avoid the loss of strength due to successive heating. The fresh sulfur mortar must be dry when it is placed in the pot, because dampness may cause foaming. 2. 4. Hold the concrete cylinder with two hands and push it against the guide bars of the capping device. Carefully lower the specimen until it rests in the cup. this step must be completed quickly before the sulfur or capping compound solidifies. The thickness of the cap should be about 3-mm (1/8 inch) and not more than 8mm (5/16 inch) in any part. 5. Before the cylinder is tested for compressive strength, the cap should be cured in order to have strength comparable to that of the concrete.