Alarm Suhu Tinggi BC550

Tag : Alarm Alarm Suhu Tinggi Sensor

High Temperature Alarm Circuit


The circuit is small regulator of temperature, us warns for the increase of temperature. The
control of temperature becomes from the thermistor TH1, that is negative factor. His resistance is
altered between in the 10K in temperature 25 C and roughly in the 1K in their 94 C. The
trimmer TR1 regulates the precise temperature in which the Q1-2, connected as darlington,
conduct, making him relay K1 close also the buzzer BZ, sound. The alarm is activated when the
temperature becomes bigger than predetermining. The thermistor it should he is placed far from
the remainder circuit, in order that this is not in danger from the temperature. The supply of
circuit becomes from battery 9V, but if he is placed in constant place, then we can him supply
with one power supply . In the contacts of relay we can connect what load we want, as a lamb,
other circuit k.a. Also can is added a LED, if we want to have also optical clue of excitation. The
regulation becomes sinking him thermistor TH1, in water which we know the temperature of (the
contacts should are well insulate so that do not have short-circuit) and regulating him trimmer,
until excited the circuit. The cable that we connect the circuit with the TH1, should be plate