0% found this document useful (0 votes)
184 views6 pages

Jetty Area

The document contains a bill of materials listing various items needed for lightning protection installation. It includes 14 line items with descriptions of the items, units of measurement, and quantities needed for projects with specifications of 3000-6000 meters of copper cable and 100-500 meters from the air terminal to structure. The total quantities of items including a 10% spare range from 1097.9405 to 1207.73455.

Uploaded by

shrieers
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
184 views6 pages

Jetty Area

The document contains a bill of materials listing various items needed for lightning protection installation. It includes 14 line items with descriptions of the items, units of measurement, and quantities needed for projects with specifications of 3000-6000 meters of copper cable and 100-500 meters from the air terminal to structure. The total quantities of items including a 10% spare range from 1097.9405 to 1207.73455.

Uploaded by

shrieers
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

S.

No

Description

Unit

1/2" , 16mm Thread Copper Air Terminal Rod of Length


500mm

Nos.

MS Plate (80 X 80 X 6) for Air Terminal Fixing at Hand RailL ofF


Gang Way and Service Platform

Nos.

Cable Lug for 50 mm2 Cable

Nos.

FRP Tube Clamping Bracket Comprising of 2 'U' Bolts, Nuts &


Washers

Nos.

Mast Cap C/W With Lock Nut & Washer for Air Terminal Fixing

Nos.

Dual Adaptor C/W With Nut & Washer for Down Conductor
Fixing

Nos.

MS Plate (100 X 100 X 6) for Steel Column.

Nos.

2" DIA MS Pipe.

Nos.

2" DIA Isolated Mast (FRP Tube)

Nos.

10

Lighting Pole Flat Rectangular Mounting Bracket of Length 8"

Nos.

11

Lighting Pole Round Mounting Bracket

Nos.

12

Stainless Steel Thru-Hole Adaptor Block

Nos.

13

Bolt, Hexagonal Head, M20 Threads, Length 150MM

Nos.

14

50mm2 Copper Cable

Mts.

50MM2 COPPER CABLE LENGTH(DOWN CONDUCTOR)


from Air terminal to
structure
3700
100
10700
1000

3000
100
10700
5500

5000
100
1000

5000

6000
100
1000

6000
100
1000

186

140

214

202

175

181

rom Air terminal to


structure
500
5500

raised
4300

1000

1000
5500

1000
1900
1000

2200

horizontal
length - 1
25332
17500
10800
36500

30500
14500
14800
32600

52530
33315
29000

horizontal
length - 2
extra length
28434
3000
300
17500
3000

23900
14000
23800

23140

total
65266
23400
42000
38500
169.166

3000
3000
3000
3000

39700
47000
42500
64900
194.1

3000
3000
3000

84670
38315
34000

7650

10760

3000

26410
183.395

1000
3500
1000

45560
46200
24000

22000

3000
3000
3000

77560
52800
29000
159.36

1000
3500
1000

64700
9259
32700

3000
3000
3000

74700
52434
37700
164.834

36575

Total +
Total

10%

Round of

Total
21

23.1

25

21

23.1

25

21

23.1

25

22

24.2

25

21

23.1

25

21

23.1

25

9.9

10

9.9

10

12

13.2

15

2.2

2.2

2.2

6.6

10

1097.9405

1207.73455

550

10% spare
186

214

202

175

181

You might also like