Professional Documents
Culture Documents
Cx600 x1 x2 M Series
Cx600 x1 x2 M Series
Product Brochure
Product Overview
X2-M16.
CX600-X1-M4
CX600-X2-M8
CX600-X2-M16
Key Features
2
Outdoor Solution
requirements.
2
CX600-X1/X2-M Series Metro Services Platform
Product Brochure
maintenance costs.
Deployment Scenario
3
providing intelligent solutions for different kinds of
Play services.
Internet
DSLAM/
FTTx
CX600
Triple Play
(Residential)
VPN(Business)
LSW/
E-FTTx
SingleMetro
Platform
BRAS
Firewall
GGSN
CX600
Converged
IP/MPLS
Backbone
Softswitch
Headend
CX600
Mobile
CSG
Access
RSG
MSC Server
RNC/BSC
Core
Services
4
CX600-X1/X2-M Series Metro Services Platform
Product Brochure
Product Specifications
The main specifications of the CX600-X1/X2-M series are summarized in the following table.
Description
Item
CX600-X1-M4
CX600-X2-M8
CX600-X2-M16
Capacity
Slots
Interface Types
10GE-WAN/LAN
GE/FE
OC-3c/STM-1c POS
Channelized STM-1
E1/CE1(75/ 120ohm)
Clock Transmission
L2 Ethernet
IEEE802.1q, IEEE802.1p, IEEE 802.3ad, IEEE 802.1ab, STP/RSTP/MSTP, DHCP, VLAN Switch, and
User Binding
Static routing, RIP, OSPF/OSPFv3, IS-IS/IS-ISv6, BGPv4/BGP4+, IPv6 over IPv4 Tunnel, IPv6CP, IPv6 ACL/
Telnet, 6PE&6vPE, IS-IS MT
L2/L3 VPN
LDP over TE, VPLS/H-VPLS, Policy Routing to VPN, L2 VPN/VLL with Martini, VLL/VPLS access L3 VPN
Instance, QinQ, MPLS/BGP L3 VPN, Inter-AS VPN
Multicast
IGMP v1/v2/v3, IGMP Snooping, IPv6 Multicast, Static Multicast Routing, PIM-SM/SSM, MBGP
QoS
WRED, H-QoS with 5 levels, VLL/PWE3 QoS, Access Network QoS Control
Network Reliability
BGP/BGP4+/ISIS/ISIS6/OSPF/OSPFv3/PIM/IGMP/LDP/RSVP-TE/L3VPN NSR
BGP/IGP/Multicast Fast Convergence, IP/LDP FRR, TE FRR, VPN FRR, VLL FRR
BFD for Static Routing, IS-IS, RSVP, LDP, TE, LSP, PW, OSPF, BGP, VRRP, PIM, Ethernet OAM(L2 LSA,
802.1ag and 802.3ah), Y.1731, PWE3 End to End Protection
Dimensions (WDH)
442mm220mm132mm(DC)
442mm220mm222mm(DC)
442mm220mm264mm(AC)
442mm220mm353mm(DC)
442mm220mm353mm(AC)
Weight
25KG(fully configured)
<350W
<550W
<650W
Environment
Work temperature:
CX600-X1-M4/CX600-X2-M8: -40C to +65C
CX600-X2-M16: 0C to +45C
Restriction on temperature variation rate: 30C/hour
Long time work humidity: 5% RH to 85% RH, non-condensing
Shot time work humidity: 0% RH to 95% RH, non-condensing
Long time work altitude: 3000 m
Other trademarks, product, service and company names mentioned are the property of their respective owners.
General Disclaimer
The information in this document may contain predictive statements including,
without limitation, statements regarding the future financial and operating results,
future product portfolio, new technology, etc. There are a number of factors
that could cause actual results and developments to differ materially from those
expressed or implied in the predictive statements. Therefore, such information
is provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice.
www.huawei.com