Site Name

Site Code

Al- Aswad

DY2859

Inspection Visit

1st ATP visit date

2nd ATP visit date

17-Mar-15

19-Apr-15

Al-Houider

DY2905

5/19/2015

3rd ATP visit date 4th ATP visit date

ATP
Power

Power comment (Task description No.) ATP BSS

1-Ubnormal sound in G2.


2-All metal Tray cable without stand and not
grounded .
3-Aviation light working abnormally.
4-surge arrestor need to directly connection
to the base bar.
5-Fuel tank need to cover lock.
28-Apr-15

7-May-15

Minor

Civil snags are Korek responsibility:


1-External tray need more fixations and
need to be grounded to bus bar.
2-Safety ladder cage need more fixation.
3-Sectors & MW support screws need to be
tightened(double net).
4- Tray must have a rubber glands to avoid
any sharp edge.
5-Tray cover need more fixation.

Minor

Major

Major

BSS comment (Task description No.)

1-External alarm cable bad quality type.


2-Roxtic must be replaced (without any silicon on it).
3-Check all feeders and jumpers (VSWR, DTF).
4-External alarm aviation light must be activated (always
not activated).

ATP TR

Minor

TR Comment (Task
description No.)

1-IF cable need more


systemization (Must be the
lack of any increases in the
cable near the MW).
2-TN most be grounded
(ground cable exist but not
connected to AMM2p).
3-MW need label 24 mm in
middle also need label on
IF cable.
4-Re systemize ICF Cable .
5- Alignment screw is
damaged & soldered most
be replaced.

ATP RF

Minor

Major

Major

RF Comment (Task description No.)

1-Feeder jumpers to antenna need more


isolation (most isolated with electrical
tape then water proof then with
electrical tape).
2-Need label on all outdoor jumpers,
feeders, three sectors.
3-Indoor jumpers need label especially
for RUS 1800.
4-Earth kit need to fix on bus bar in right
way.
5-Cell A 1800 jumpers too short inside
RBS cabinet.
6-Cell A DX1 jumper damage must be
replaced

Status of
visit

Minor

Major