Monitoring Relays
Monitoring Relays
MODELS
D1 VCR1, D1 VCR2
VCT D2, VCF D2, D2 VCT1, D1 VCT1,
S2 VMR 4, S2 VMR 5,
D2 EFR1, F3 EFR 1, OCS D1,
S2 CMR2, S2 CMR3, S2 CMR4,
OFS D1, S2 FMR1,
RPT D2, RPF D2, CBCT, CT
FEATURES
PROTECTIONS / FUNCTIONS
Under/Over Voltage,
Under/Over Current
Under/Over Frequency
Reverse Power
Earth Fault/Ground Fault
Earth leakage
Ordering Instructions
Product Family Name
Model Name
System Supply Voltage
& frequency
Aux. Supply/Control
supply voltage
Current input (1A or 5A)
17
D1 VCR2
1 Phase Voltage
Monitoring Relay
VCT D2
1 Phase Voltage
Monitoring Relay
VCF D2
Voltage Monitoring
Relay, 3-3W
Voltage Monitoring
Relay, 3-4W
System Supply
2 CO
2 CO
2 CO
76 x 30.5 x 117.5
68 mm centre to centre / 35 mm rail
mounting
76 x 30.5 x 117.5
68 mm centre to centre / 35 mm rail
mounting
76 x 56.5 x 117.5
67 x 46
/ 35 mm rail
mounting
76 x 56.5 x 117.5
67 x 46
/ 35 mm rail
mounting
Over Voltage
OV SET
OV RESET
OV SET
3 Ph
OV RESET
1 Ph N
UV RESET
UV RESET
UV SET
UV SET
TD 2 to 5sec.
13
14
TD
Reset
DLY=
180 Sec.
15
Reset
DLY=
180 Sec.
13
14
16
17
13
15
16
18
TD
T on
2
P.ON
DLY= 180 Sec.
13
TD
1 to 10sec.
TRIP DLY
2 to 5Sec.
1 to 10sec.
L
O
A
D
N
OFF
L
O
A
D
L
N
OFF
ON
ON
L
O
A
D
R
Y
B
D1 VCR1
1
OFF
N/V
N/V
L
O
A
D
Y
B
N
OFF
D1 VCR2
1
N/V
D1 VCR1
7
13
14
15
ON
1 2 3 4 5 6
1 2 3 4 5 6
VCT D2
VCF D2
A/M
LINK
A/M
LINK
7 8 9 10 11 12
7 8 9 10 11 12
13 14 15
13 14 151617 18
13 14 151617 18
N/V
ON
D2 VCT1
Voltage Monitoring
Relay, 3-3W
S2 VMR4
Voltage Monitoring
Relay
Voltage Monitoring
Relay, 3-4W
US
S2 VMR5
Voltage Monitoring
Relay, 3-3W
US
US
285-425V AC (Variable)
165-225V AC (Variable)
75-115V AC (Variable)
165-245V AC (Variable)
95-135V AC (Variable)
45-65V AC (Variable)
Ph Ph Sensing:
For 380-440V AC
For 220-240V AC
For 100-120V AC
Ph N Sensing:
For 380-440V AC
For 220-240V AC
For 100-120V AC
400-520V AC (Variable)
230-290V AC (Variable)
105-145V AC (Variable)
230-310V AC (Variable)
130-170V AC (Variable)
60-80V AC (Variable)
230-310V AC (Variable)
130-170V AC (Variable)
60-80V AC (Variable)
76 X 56.5 X 117.5
67 x 46
/ 35 mm rail mounting
90 X 35 X 60
35 mm Rail Mounting
90 X 35 X 60
35 mm Rail Mounting
OV SET
OV SET
OV SET
OV SET
OV RESET
OV RESET
OV RESET
OV RESET
3 Ph
3 Ph N
3 Ph
3 Ph N
UV RESET
UV SET
13
13
UV SET
TD
14
13
14
16
17
15
13
15
16
18
L
O
A
D
TD
1 to 10sec.
T on
L
O
A
D
N
UV SET
TD
1 to 10sec.
TD
1 to 10sec.
UV RESET
UV RESET
UV RESET
TD
3.5 sec.
10
11
10
12
T on
1 to 10sec.
R
Y
B
UV SET
TD
1 to 10sec.
TD
L
O
A
D
10
11
10
12
TD
T on
1 to 10sec.
R
Y
B
N
L
O
A
D
3 or 4 Wire
selection link
OFF
DOL STARTER
D2 VCT1
19
S2 CMR2
Supply Voltage
System
Auxiliary
Ext. Input
Output contact
US
110-120/220-240/380-440 V AC 20%,
12 V DC/24/30 V DC10%
1 Amp / 5 Amp (Secondary) CT or 250/500 mA
1 CO
EF Trip Setting
Under Current
N.A.
76 x 30.5 x 117.5
68mm centre to centre / 35mm rail Mounting
90 X 35 X 60
35 mm Rail Mounting
Trip setting
Over Current
Power On Delay
Trip Time Delay
Resetting
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
Aux. Supply
Aux. Supply
OC SetPoint
OC SetPoint
OC Reset
OC Reset
UC Reset
UC SetPoint
Current Input
Current Input
T ON
2 to 5 sec.
Application
D2 EFR1, S2 CMR3, S2 CMR4
can be used for breaker tripping
T ON
1 to 10 sec.
Td 1 to 10 sec.
13
14
10
11
13
15
9 10
12
L
O
A
D
L
N
BUSBAR
TRIP COIL
BATTERY
TRIP COIL
N/V
C.B.
1 2
DOL STARTER
OCS D1
ON OFF
RELAY CONTACTS
C.T.
RELAY COIL
AUX.
SUPPLY
7
FAULT
A
CIRCUIT TO BE
PROTECTED
13 14 15
Interlocking circuit is required for shunt trip coil as shunt coil require pulse
only for tripping, incase of contineous power shunt coil burns.
20
AUTO
RESET
Td 1 to 10 sec.
L
O
A
D
F3 EFR1
New
S2 CMR3
S2 CMR4
US
US
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
0.1-1.0 / 1-10 Sec. (Adjustable)
Manual / Remote (Selectable)
550gms.
N.A.
N.A.
N.A.
N.A.
0.1-1.0 / 1-10 Sec. (Adjustable)
Manual / Remote (Selectable)
550gms.
1 -10 Sec.(Adjustable)
0.1 - 1 Sec.(Adjustable)
Manual
140 gms
1 -10 Sec.(Adjustable)
0.1 Sec to 1 Sec.(Adjustable)
Manual
140 gms
76 x 56.5 x 117.5
67 x 46
/ 35 mm rail Mounting
96 x 96 X 80 mm
92 X 92
90 X 35 X 60
35 mm Rail Mounting
90 X 35 X 60
35 mm Rail Mounting
1CO / (2CO)
In
Td
13
14
16
17
13
15
16
18
Td
EXTERNAL
5 Amp. CT.
EXTERNAL
5 Amp. CT.
CBCT ( ZCT)
R
Y
B
N/V
L
O
A
D
L
O
A
D
R
Y
B
L
O
A
D
OFF
N/V
OFF ON
1 2 3 4 5 6
AUX.
SUPPLY
D2 EFR1
13 14 15 16 17 18
*Use either
3 x 5A Ext. CTs
or 3 x 1A Ext. CTs
or 1 x 5A (or 1A) CBCT
*Use either
3 x 5A Ext. CTs
or 3 x 1A Ext. CTs
or 1 x 5A (or 1A) CBCT
S2 CMR 4
7 8 9 10 11 12
21
ON
S2 FMR1
Supply Voltage
System
Auxiliary
Ext. Input
Output contact
Trip setting
Under Frequency
Over Frequency
Reverse Power
Power On Delay
Trip Time Delay
Resetting
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
US
1 CO + 1 CO / 2 CO
N.A.
50 Hz - 70 Hz
40 Hz - 60 Hz (Variable)
50 Hz - 70 Hz (Variable)
1 - 10 Sec.(Adjustable) 1 Sec.
1 - 10 Sec.(Adjustable) 1 Sec.
Auto / Manual
130 gms
76 x 30.5 x 117.5
68 centre to centre / 35 mm Rail Mounting
90 X 35 X 60
35 mm Rail Mounting
Aux. Supply
Aux. Supply
OF SetPoint
OF SetPoint
OF Reset
OF Reset
UF Reset
UF SetPoint
Freq. Input
Freq. Input
T ON
2 to 5 sec.
T ON
1 to 10 sec.
Td 1 to 10 sec.
13
14
8 10
11
13
15
9 10
12
AUTO
RESET
Td
1 to 10 sec.
L
O
A
D
L
N
OFF
L
O
A
D
ON
OFF
N/V
DOL STARTER
N/V
DOL STARTER
OFS D1
13
14
15
22
ON
RPF D2
2% - 20% (adjustable)
1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable.)
Auto / Manual
460 gms.
2% - 20% (adjustable)
1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable)
Auto / Manual
460 gms.
76 x 56.5 x 117.5
67 x 46
/ 35 mm Rail Mounting
76 x 56.5 x 117.5
67 x 46
/ 35 mm Rail Mounting
POWER
SOURCE
POWER
SOURCE
ASYN.
MOTOR
ASYN.
MOTOR
RPT D2 / RPF D2
3 Ph
Supply
RPT D2 / RPF D2
Forward Power
Reverse Power
Recovery
Level
Current Tripping
Level
13
14 16
17
13
15 16
18
Td 1 to 10 sec.
T ON
1 to 10 sec.
ASYN.
MOTOR
LOAD
L
O
A
D
RPF D2
A/M
LINK
23