For heavy-duty applications,

contactors designed to switch


up to 2750 amps

Protection
and intelligence
combined

The LT6-P electronic multifunction protection relay is ideally


suited to high performance applications. It provides protection
for your motors in virtually any application or operating condition.

It enables automatic control of different methods of starting:

CV1 Contactors

For loads up to 950 amps inductive, 1000 amps resistive


Voltage up to 660 VAC or 440 VDC
Frequency up to 200 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

All the functionalities are programmable with parameters entered


locally or using a PC software.

It integrates into all the most complex automation systems


through its communication functions on UNITELWAY,
JBUS, MODBUS protocols.

Thermal Overload Relays from 6 to 2750 A

Manual Starter and Protector


The TELEMECANIQUE GV2 and GV3 devices incorporate a manual
disconnect, overload relay and instantaneous magnetic trip mechanism
in one compact device. They can be used as standalone manual
starters or to protect each branch circuit of a group motor installation.

in hard ambient conditions: high temperature, dust, humidity


with severe duty: fast operating cycles, use of DC injection braking.

cross-line (reversing or non-reversing)


star/delta
2-speed

Contactors and

Request document
8539CT9201R6/97

The LT3-S thermistor relay provides complementary protection


by direct measurement of the temperature of motors equipped
with PTC thermistor probes, for operation:

INTEGRAL Self-Protected Starters


TELEMECANIQUE INTEGRAL self-protected starters combine
circuit breaker, contactor and dual function overload relay for
coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated
protection. INTEGRAL starters can reduce panel space requirements
by 40 to 60%. 18A, 32A and 63A models are available.

Protect your motor


from damaging
over-temperatures

Request document
252OCT9501R6/97

Enclosed IEC Starters


D-Line starters and INTEGRAL self-protected starters are available
in metal NEMA Type 1 and 12 enclosures. These enclosed devices
utilize INSTAKIT components for the addition of cover mounted
pilot devices. INSTAKIT components are pre-wired control operator
kits that use a universal connector for quick, easy installation.
Request following documents
9502HO9401R0996 - INSTAKIT pre-wired starter access
9502HO9402R0996 - D-Line non-combination starters
9502HO9403R0996 - INTEGRAL starters
8502CT0101 - IEC SMCE contactors and starters
8502BR0102-TeSys-The New D-LINE

D-Line, K-Line and F-Line contactors and overload relays are the
largest selling motor starting and protection devices in the world. They
offer starting for motors up to 800 hp at 480 AC volts and switching
of resistive loads up to 1350 amps. They are UL-listed, CSA-certified
and CE-marked for use in North America and around the world.

CV3 Contactors

For loads up to 1800 amps inductive, 2750 amps resistive


Voltage up to 1000 VAC or 1500 VDC
Frequency up to 400 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

Visit the Square D web site


at www.SquareD.com

Order Number 8502BR0101


Printed in U.S.A.

2001 Schneider Electric


All Rights Reserved

Schneider Electric Brands

Get more with the worlds Power & Control specialist.

Front mounted
additional blocks

Coil Suffixes

Low Consumption

DC

DC

Hz

50/60

50*

60*

24 V
48 V
72 V
110 V
120 V
208 V
220 V
230 V
240 V
250 V
380 V
400 V
415 V
440 V

B7
E7
F7
G7
M7
P7
U7
Q7
V7
N7
R7

B5
E5
F5
M5
P5
U5
Q5
V5
N5
R5

B6 BD
E6 ED
SD
F6 FD
G6
L6
M6 MD
U6
UD
Q6
R6 RD*

1
2

4
3
2
1
-

LA1-KN20
LA1-KN11
LA1-KN02

1
2
3
4

LA1-KN40
LA1-KN31
LA1-KN22
LA1-KN13
LA1-KN04

2
1
-

1
2

NO NC NC NO

NO NC

LAD-N20
LAD-N11
LAD-N02

4
3
2
1
-

1
2
3
4

LAD-N40
LAD-N31
LAD-N22
LAD-N13
LAD-N04

NO

LAD-C22

LA1-DX20

2
2

2
1

1
2
1

40/400

FW
FW
MW
MW
MW

1
2

F
M
P
U
Q
V
N
R

QW
QW
QW
QW

Contactors

220/230
380/400
415 V
500 V
660/690
1000 V
200 V
230 V
460/480
575 V

V
V

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP

AC
DC
Low Consumption DC (< 2.4 W)
A1
A2

6
20
10
1.5
2.2
2.2
3
3
1.5
3
3
LC1-K06
LP1-K06
LP4-K06   3
10
01

Part number suffixes to specify power pole/


auxiliary contact configuration

01

004

008

0.11

Standard overload relays

0.16

LR2-K0301
0.36

0.54

1.2

9
25
10
2.2
4
4
5.5
5.5
2
5
7.5
LC1-D09
LC1-D09
LC1-D09  

12
25
10
3
5.5
5.5
7.5
7.5
3
7.5
10
LC1-D12
LC1-D02
LC1-D02

18
32
8
4
7.5
9
10
10
5
10
15
LC1-D18
LC1-D18
LC1-D18



25
40
6
5.5
1111
11
15
15
7.5
15
20
LC1-D25
LC1-D25
LC1-D25



32
50
6
7.5
15
15
18.5
18.5
10
20
30



40
60
3
11
18.5
22
22
30
10
30
30

50
80
3
15
22
25
30
33
15
40
40

65
80
3
18.5
30
37
37
37
20
50
50

80
125
2
22
37
45
55
45
30
60
60

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

10
01

3.7

10

LR2-K0320

0.25

LRD-02

0.4

0.63

LRD-03

LRD-04

LRD-05

1.6

LRD-06

2.5

LRD-07

25

LR2-K0307

30

10

LRD-10

12

18

LRD-08

LRD-14

23

LRD-21

48

65

LRD-3355

LRD-3359

LRD-3353

LRD-3357

23

11.5

40

LRD-3322

3.7

14

0.16

LRD-01

LR2-K0304

LR2-K0308

LR2-K0314

0.1
1.2

2.6

5.5

LR2-K0312
Class 10

0.8

1.8

17

0.36

LR2-K0301

LR2-K0305

LR2-K0307

Direct mounting on the contactor

0.23

LR2-K0302

LR2-K0304

Multifunction overload relays

10
01

12
20
10
3
5.5
5.5
4
4
3
7.5
10
LC1-K12
LC1-K12
LP4-K12   3

004
008

10

00

9
20
10
2.2
4
4
4
4
3
5
5
LC1-K09
LP1-K09
LP4-K09   3

32

37

55

32

LRD-32

50

70

80

104

LRD-3361

LRD-3365

LR2-K0312

12

LRD-12

18

LR2-K0321

5.5

LRD-16
8

LRD-22
13

0.2 A

17

LRD-35
25

30

LRD-3363

5A

LT6-P0M005FM

63

38

25 A

LT6-P0M025FM

(1) Except LC1-D115, LC1-D150


(2) Only LCI, LPI
(3) For LP4-D
For more information refer to publication 8502CT0101

80

Max. inductive current AC3


Max. resistive current AC1
Max. wire size

11

LA1-DY20

- 30s

NC

LAD-S2

NO

NO

0.1 - 3s
LAD-T0
1 - 30s LAD-T2
10 - 180s LAD-T4

NC

0.1 - 3s
LAD-R0
1 - 30s LAD-R2
10 - 180s LAD-R4

LAD-8N11(1)
LAD-8N20(1)
LAD-8N02(1)

*Except K

Maximum 3 phase
horsepower
ratings

NO

400

Maximum 3 phase
power ratings per
IEC 947-4

LA1-DZ40
LA1-DZ31

NC

NO NC

AC/DC AC

BL
EL
SL

NO

NO NO NC

115
250
250 MCM
30
55
59
75
80
75
40
75
100

150
250
250 MCM
40
75
80
90
100
90
50
100
125

LC1-D115

LC1-D150  7

LC1-D115

LC1-D150

60

100

LR9-D5367
LR9-D5369
90

150

AC

2
1
-

NO NC

115
175

30
55
59
75
80
65
30
40
75
100

150
200
3/
40
7755
80
90
100
65
40
50
100
125

LC1-F115

185
200
3/
55
9900
100
110
110
100
50
60
125
150

LC1-F150

30

LC1-F185

225
200
300 MCM
63
110
110
129
129
100
60
75
150
150

265
285
300 MCM
75
132
140
160
160
147
60
75
150
200

330
360
300 MCM
100
160
180
200
220
160
75
100
200
250

400
420
600 MCM
110
200
220
257
280
185
100
125
250
300

LC1-F225

LC1-F265

LC1-F330

LC1-F400

132

50

LR9-F5357

500
700
2 x 600 MCM
147
250
280
355
335
335
150
200
400
500
LC1-F500

630
1000
3 x 600 MCM
200
335
375
400
450
450
250
300
600
800

800
1000
3 x 600 MCM
250
450
450
450
475
450
450
800
900

LC1-F630

LC1-F800

220

LR9-F5371
200

LR9-F5363
48

80

60

330

LR9-F7375

100

LR9-F7379

LR9-F5367

300

500

LR9-F5369

LR9-F7381

90

LT6-P0M005FM + LTC-CT001

150

1A
5A

380

630

630

780
1350
4 x 750 MCM

450
900
900
LC1-F780

NO NC

NO NC

NO NC

Built-in auxiliary contacts

750
1000
800
1250
2 x 80mm x 5mm55552 x 80mm x 5mm5555
220
280
400
500
425
590
500
600
560
670
530
530
LC1BL3

22

LC1BM3

22

1500
2000
3 x 100mm x 5mm5555
425
750
800
750
750
670
LC1BP3

22

1800
2750
4 x 100mm x 5mm5555
500
900
900
900
900
750
LC1BR3

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP
AC
DC

22

1A + LR2D1305
5A + LR2D1310
2750 A

2750 A

Front mounted
additional blocks

Coil Suffixes

Low Consumption

DC

DC

Hz

50/60

50*

60*

24 V
48 V
72 V
110 V
120 V
208 V
220 V
230 V
240 V
250 V
380 V
400 V
415 V
440 V

B7
E7
F7
G7
M7
P7
U7
Q7
V7
N7
R7

B5
E5
F5
M5
P5
U5
Q5
V5
N5
R5

B6 BD
E6 ED
SD
F6 FD
G6
L6
M6 MD
U6
UD
Q6
R6 RD*

1
2

4
3
2
1
-

LA1-KN20
LA1-KN11
LA1-KN02

1
2
3
4

LA1-KN40
LA1-KN31
LA1-KN22
LA1-KN13
LA1-KN04

2
1
-

1
2

NO NC NC NO

NO NC

LAD-N20
LAD-N11
LAD-N02

4
3
2
1
-

1
2
3
4

LAD-N40
LAD-N31
LAD-N22
LAD-N13
LAD-N04

NO

LAD-C22

LA1-DX20

2
2

2
1

1
2
1

40/400

FW
FW
MW
MW
MW

1
2

F
M
P
U
Q
V
N
R

QW
QW
QW
QW

Contactors

220/230
380/400
415 V
500 V
660/690
1000 V
200 V
230 V
460/480
575 V

V
V

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP

AC
DC
Low Consumption DC (< 2.4 W)
A1
A2

6
20
10
1.5
2.2
2.2
3
3
1.5
3
3
LC1-K06
LP1-K06
LP4-K06   3
10
01

Part number suffixes to specify power pole/


auxiliary contact configuration

01

004

008

0.11

Standard overload relays

0.16

LR2-K0301
0.36

0.54

1.2

9
25
10
2.2
4
4
5.5
5.5
2
5
7.5
LC1-D09
LC1-D09
LC1-D09  

12
25
10
3
5.5
5.5
7.5
7.5
3
7.5
10
LC1-D12
LC1-D02
LC1-D02

18
32
8
4
7.5
9
10
10
5
10
15
LC1-D18
LC1-D18
LC1-D18



25
40
6
5.5
1111
11
15
15
7.5
15
20
LC1-D25
LC1-D25
LC1-D25



32
50
6
7.5
15
15
18.5
18.5
10
20
30



40
60
3
11
18.5
22
22
30
10
30
30

50
80
3
15
22
25
30
33
15
40
40

65
80
3
18.5
30
37
37
37
20
50
50

80
125
2
22
37
45
55
45
30
60
60

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

10
01

3.7

10

LR2-K0320

0.25

LRD-02

0.4

0.63

LRD-03

LRD-04

LRD-05

1.6

LRD-06

2.5

LRD-07

25

LR2-K0307

30

10

LRD-10

12

18

LRD-08

LRD-14

23

LRD-21

48

65

LRD-3355

LRD-3359

LRD-3353

LRD-3357

23

11.5

40

LRD-3322

3.7

14

0.16

LRD-01

LR2-K0304

LR2-K0308

LR2-K0314

0.1
1.2

2.6

5.5

LR2-K0312
Class 10

0.8

1.8

17

0.36

LR2-K0301

LR2-K0305

LR2-K0307

Direct mounting on the contactor

0.23

LR2-K0302

LR2-K0304

Multifunction overload relays

10
01

12
20
10
3
5.5
5.5
4
4
3
7.5
10
LC1-K12
LC1-K12
LP4-K12   3

004
008

10

00

9
20
10
2.2
4
4
4
4
3
5
5
LC1-K09
LP1-K09
LP4-K09   3

32

37

55

32

LRD-32

50

70

80

104

LRD-3361

LRD-3365

LR2-K0312

12

LRD-12

18

LR2-K0321

5.5

LRD-16
8

LRD-22
13

0.2 A

17

LRD-35
25

30

LRD-3363

5A

LT6-P0M005FM

63

38

25 A

LT6-P0M025FM

(1) Except LC1-D115, LC1-D150


(2) Only LCI, LPI
(3) For LP4-D
For more information refer to publication 8502CT0101

80

Max. inductive current AC3


Max. resistive current AC1
Max. wire size

11

LA1-DY20

- 30s

NC

LAD-S2

NO

NO

0.1 - 3s
LAD-T0
1 - 30s LAD-T2
10 - 180s LAD-T4

NC

0.1 - 3s
LAD-R0
1 - 30s LAD-R2
10 - 180s LAD-R4

LAD-8N11(1)
LAD-8N20(1)
LAD-8N02(1)

*Except K

Maximum 3 phase
horsepower
ratings

NO

400

Maximum 3 phase
power ratings per
IEC 947-4

LA1-DZ40
LA1-DZ31

NC

NO NC

AC/DC AC

BL
EL
SL

NO

NO NO NC

115
250
250 MCM
30
55
59
75
80
75
40
75
100

150
250
250 MCM
40
75
80
90
100
90
50
100
125

LC1-D115

LC1-D150  7

LC1-D115

LC1-D150

60

100

LR9-D5367
LR9-D5369
90

150

AC

2
1
-

NO NC

115
175

30
55
59
75
80
65
30
40
75
100

150
200
3/
40
7755
80
90
100
65
40
50
100
125

LC1-F115

185
200
3/
55
9900
100
110
110
100
50
60
125
150

LC1-F150

30

LC1-F185

225
200
300 MCM
63
110
110
129
129
100
60
75
150
150

265
285
300 MCM
75
132
140
160
160
147
60
75
150
200

330
360
300 MCM
100
160
180
200
220
160
75
100
200
250

400
420
600 MCM
110
200
220
257
280
185
100
125
250
300

LC1-F225

LC1-F265

LC1-F330

LC1-F400

132

50

LR9-F5357

500
700
2 x 600 MCM
147
250
280
355
335
335
150
200
400
500
LC1-F500

630
1000
3 x 600 MCM
200
335
375
400
450
450
250
300
600
800

800
1000
3 x 600 MCM
250
450
450
450
475
450
450
800
900

LC1-F630

LC1-F800

220

LR9-F5371
200

LR9-F5363
48

80

60

330

LR9-F7375

100

LR9-F7379

LR9-F5367

300

500

LR9-F5369

LR9-F7381

90

LT6-P0M005FM + LTC-CT001

150

1A
5A

380

630

630

780
1350
4 x 750 MCM

450
900
900
LC1-F780

NO NC

NO NC

NO NC

Built-in auxiliary contacts

750
1000
800
1250
2 x 80mm x 5mm55552 x 80mm x 5mm5555
220
280
400
500
425
590
500
600
560
670
530
530
LC1BL3

22

LC1BM3

22

1500
2000
3 x 100mm x 5mm5555
425
750
800
750
750
670
LC1BP3

22

1800
2750
4 x 100mm x 5mm5555
500
900
900
900
900
750
LC1BR3

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP
AC
DC

22

1A + LR2D1305
5A + LR2D1310
2750 A

2750 A

Front mounted
additional blocks

Coil Suffixes

Low Consumption

DC

DC

Hz

50/60

50*

60*

24 V
48 V
72 V
110 V
120 V
208 V
220 V
230 V
240 V
250 V
380 V
400 V
415 V
440 V

B7
E7
F7
G7
M7
P7
U7
Q7
V7
N7
R7

B5
E5
F5
M5
P5
U5
Q5
V5
N5
R5

B6 BD
E6 ED
SD
F6 FD
G6
L6
M6 MD
U6
UD
Q6
R6 RD*

1
2

4
3
2
1
-

LA1-KN20
LA1-KN11
LA1-KN02

1
2
3
4

LA1-KN40
LA1-KN31
LA1-KN22
LA1-KN13
LA1-KN04

2
1
-

1
2

NO NC NC NO

NO NC

LAD-N20
LAD-N11
LAD-N02

4
3
2
1
-

1
2
3
4

LAD-N40
LAD-N31
LAD-N22
LAD-N13
LAD-N04

NO

LAD-C22

LA1-DX20

2
2

2
1

1
2
1

40/400

FW
FW
MW
MW
MW

1
2

F
M
P
U
Q
V
N
R

QW
QW
QW
QW

Contactors

220/230
380/400
415 V
500 V
660/690
1000 V
200 V
230 V
460/480
575 V

V
V

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP

AC
DC
Low Consumption DC (< 2.4 W)
A1
A2

6
20
10
1.5
2.2
2.2
3
3
1.5
3
3
LC1-K06
LP1-K06
LP4-K06   3
10
01

Part number suffixes to specify power pole/


auxiliary contact configuration

01

004

008

0.11

Standard overload relays

0.16

LR2-K0301
0.36

0.54

1.2

9
25
10
2.2
4
4
5.5
5.5
2
5
7.5
LC1-D09
LC1-D09
LC1-D09  

12
25
10
3
5.5
5.5
7.5
7.5
3
7.5
10
LC1-D12
LC1-D02
LC1-D02

18
32
8
4
7.5
9
10
10
5
10
15
LC1-D18
LC1-D18
LC1-D18



25
40
6
5.5
1111
11
15
15
7.5
15
20
LC1-D25
LC1-D25
LC1-D25



32
50
6
7.5
15
15
18.5
18.5
10
20
30



40
60
3
11
18.5
22
22
30
10
30
30

50
80
3
15
22
25
30
33
15
40
40

65
80
3
18.5
30
37
37
37
20
50
50

80
125
2
22
37
45
55
45
30
60
60

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

10
01

3.7

10

LR2-K0320

0.25

LRD-02

0.4

0.63

LRD-03

LRD-04

LRD-05

1.6

LRD-06

2.5

LRD-07

25

LR2-K0307

30

10

LRD-10

12

18

LRD-08

LRD-14

23

LRD-21

48

65

LRD-3355

LRD-3359

LRD-3353

LRD-3357

23

11.5

40

LRD-3322

3.7

14

0.16

LRD-01

LR2-K0304

LR2-K0308

LR2-K0314

0.1
1.2

2.6

5.5

LR2-K0312
Class 10

0.8

1.8

17

0.36

LR2-K0301

LR2-K0305

LR2-K0307

Direct mounting on the contactor

0.23

LR2-K0302

LR2-K0304

Multifunction overload relays

10
01

12
20
10
3
5.5
5.5
4
4
3
7.5
10
LC1-K12
LC1-K12
LP4-K12   3

004
008

10

00

9
20
10
2.2
4
4
4
4
3
5
5
LC1-K09
LP1-K09
LP4-K09   3

32

37

55

32

LRD-32

50

70

80

104

LRD-3361

LRD-3365

LR2-K0312

12

LRD-12

18

LR2-K0321

5.5

LRD-16
8

LRD-22
13

0.2 A

17

LRD-35
25

30

LRD-3363

5A

LT6-P0M005FM

63

38

25 A

LT6-P0M025FM

(1) Except LC1-D115, LC1-D150


(2) Only LCI, LPI
(3) For LP4-D
For more information refer to publication 8502CT0101

80

Max. inductive current AC3


Max. resistive current AC1
Max. wire size

11

LA1-DY20

- 30s

NC

LAD-S2

NO

NO

0.1 - 3s
LAD-T0
1 - 30s LAD-T2
10 - 180s LAD-T4

NC

0.1 - 3s
LAD-R0
1 - 30s LAD-R2
10 - 180s LAD-R4

LAD-8N11(1)
LAD-8N20(1)
LAD-8N02(1)

*Except K

Maximum 3 phase
horsepower
ratings

NO

400

Maximum 3 phase
power ratings per
IEC 947-4

LA1-DZ40
LA1-DZ31

NC

NO NC

AC/DC AC

BL
EL
SL

NO

NO NO NC

115
250
250 MCM
30
55
59
75
80
75
40
75
100

150
250
250 MCM
40
75
80
90
100
90
50
100
125

LC1-D115

LC1-D150  7

LC1-D115

LC1-D150

60

100

LR9-D5367
LR9-D5369
90

150

AC

2
1
-

NO NC

115
175

30
55
59
75
80
65
30
40
75
100

150
200
3/
40
7755
80
90
100
65
40
50
100
125

LC1-F115

185
200
3/
55
9900
100
110
110
100
50
60
125
150

LC1-F150

30

LC1-F185

225
200
300 MCM
63
110
110
129
129
100
60
75
150
150

265
285
300 MCM
75
132
140
160
160
147
60
75
150
200

330
360
300 MCM
100
160
180
200
220
160
75
100
200
250

400
420
600 MCM
110
200
220
257
280
185
100
125
250
300

LC1-F225

LC1-F265

LC1-F330

LC1-F400

132

50

LR9-F5357

500
700
2 x 600 MCM
147
250
280
355
335
335
150
200
400
500
LC1-F500

630
1000
3 x 600 MCM
200
335
375
400
450
450
250
300
600
800

800
1000
3 x 600 MCM
250
450
450
450
475
450
450
800
900

LC1-F630

LC1-F800

220

LR9-F5371
200

LR9-F5363
48

80

60

330

LR9-F7375

100

LR9-F7379

LR9-F5367

300

500

LR9-F5369

LR9-F7381

90

LT6-P0M005FM + LTC-CT001

150

1A
5A

380

630

630

780
1350
4 x 750 MCM

450
900
900
LC1-F780

NO NC

NO NC

NO NC

Built-in auxiliary contacts

750
1000
800
1250
2 x 80mm x 5mm55552 x 80mm x 5mm5555
220
280
400
500
425
590
500
600
560
670
530
530
LC1BL3

22

LC1BM3

22

1500
2000
3 x 100mm x 5mm5555
425
750
800
750
750
670
LC1BP3

22

1800
2750
4 x 100mm x 5mm5555
500
900
900
900
900
750
LC1BR3

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP
AC
DC

22

1A + LR2D1305
5A + LR2D1310
2750 A

2750 A

Front mounted
additional blocks

Coil Suffixes

Low Consumption

DC

DC

Hz

50/60

50*

60*

24 V
48 V
72 V
110 V
120 V
208 V
220 V
230 V
240 V
250 V
380 V
400 V
415 V
440 V

B7
E7
F7
G7
M7
P7
U7
Q7
V7
N7
R7

B5
E5
F5
M5
P5
U5
Q5
V5
N5
R5

B6 BD
E6 ED
SD
F6 FD
G6
L6
M6 MD
U6
UD
Q6
R6 RD*

1
2

4
3
2
1
-

LA1-KN20
LA1-KN11
LA1-KN02

1
2
3
4

LA1-KN40
LA1-KN31
LA1-KN22
LA1-KN13
LA1-KN04

2
1
-

1
2

NO NC NC NO

NO NC

LAD-N20
LAD-N11
LAD-N02

4
3
2
1
-

1
2
3
4

LAD-N40
LAD-N31
LAD-N22
LAD-N13
LAD-N04

NO

LAD-C22

LA1-DX20

2
2

2
1

1
2
1

40/400

FW
FW
MW
MW
MW

1
2

F
M
P
U
Q
V
N
R

QW
QW
QW
QW

Contactors

220/230
380/400
415 V
500 V
660/690
1000 V
200 V
230 V
460/480
575 V

V
V

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP

AC
DC
Low Consumption DC (< 2.4 W)
A1
A2

6
20
10
1.5
2.2
2.2
3
3
1.5
3
3
LC1-K06
LP1-K06
LP4-K06   3
10
01

Part number suffixes to specify power pole/


auxiliary contact configuration

01

004

008

0.11

Standard overload relays

0.16

LR2-K0301
0.36

0.54

1.2

9
25
10
2.2
4
4
5.5
5.5
2
5
7.5
LC1-D09
LC1-D09
LC1-D09  

12
25
10
3
5.5
5.5
7.5
7.5
3
7.5
10
LC1-D12
LC1-D02
LC1-D02

18
32
8
4
7.5
9
10
10
5
10
15
LC1-D18
LC1-D18
LC1-D18



25
40
6
5.5
1111
11
15
15
7.5
15
20
LC1-D25
LC1-D25
LC1-D25



32
50
6
7.5
15
15
18.5
18.5
10
20
30



40
60
3
11
18.5
22
22
30
10
30
30

50
80
3
15
22
25
30
33
15
40
40

65
80
3
18.5
30
37
37
37
20
50
50

80
125
2
22
37
45
55
45
30
60
60

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

10
01

3.7

10

LR2-K0320

0.25

LRD-02

0.4

0.63

LRD-03

LRD-04

LRD-05

1.6

LRD-06

2.5

LRD-07

25

LR2-K0307

30

10

LRD-10

12

18

LRD-08

LRD-14

23

LRD-21

48

65

LRD-3355

LRD-3359

LRD-3353

LRD-3357

23

11.5

40

LRD-3322

3.7

14

0.16

LRD-01

LR2-K0304

LR2-K0308

LR2-K0314

0.1
1.2

2.6

5.5

LR2-K0312
Class 10

0.8

1.8

17

0.36

LR2-K0301

LR2-K0305

LR2-K0307

Direct mounting on the contactor

0.23

LR2-K0302

LR2-K0304

Multifunction overload relays

10
01

12
20
10
3
5.5
5.5
4
4
3
7.5
10
LC1-K12
LC1-K12
LP4-K12   3

004
008

10

00

9
20
10
2.2
4
4
4
4
3
5
5
LC1-K09
LP1-K09
LP4-K09   3

32

37

55

32

LRD-32

50

70

80

104

LRD-3361

LRD-3365

LR2-K0312

12

LRD-12

18

LR2-K0321

5.5

LRD-16
8

LRD-22
13

0.2 A

17

LRD-35
25

30

LRD-3363

5A

LT6-P0M005FM

63

38

25 A

LT6-P0M025FM

(1) Except LC1-D115, LC1-D150


(2) Only LCI, LPI
(3) For LP4-D
For more information refer to publication 8502CT0101

80

Max. inductive current AC3


Max. resistive current AC1
Max. wire size

11

LA1-DY20

- 30s

NC

LAD-S2

NO

NO

0.1 - 3s
LAD-T0
1 - 30s LAD-T2
10 - 180s LAD-T4

NC

0.1 - 3s
LAD-R0
1 - 30s LAD-R2
10 - 180s LAD-R4

LAD-8N11(1)
LAD-8N20(1)
LAD-8N02(1)

*Except K

Maximum 3 phase
horsepower
ratings

NO

400

Maximum 3 phase
power ratings per
IEC 947-4

LA1-DZ40
LA1-DZ31

NC

NO NC

AC/DC AC

BL
EL
SL

NO

NO NO NC

115
250
250 MCM
30
55
59
75
80
75
40
75
100

150
250
250 MCM
40
75
80
90
100
90
50
100
125

LC1-D115

LC1-D150  7

LC1-D115

LC1-D150

60

100

LR9-D5367
LR9-D5369
90

150

AC

2
1
-

NO NC

115
175

30
55
59
75
80
65
30
40
75
100

150
200
3/
40
7755
80
90
100
65
40
50
100
125

LC1-F115

185
200
3/
55
9900
100
110
110
100
50
60
125
150

LC1-F150

30

LC1-F185

225
200
300 MCM
63
110
110
129
129
100
60
75
150
150

265
285
300 MCM
75
132
140
160
160
147
60
75
150
200

330
360
300 MCM
100
160
180
200
220
160
75
100
200
250

400
420
600 MCM
110
200
220
257
280
185
100
125
250
300

LC1-F225

LC1-F265

LC1-F330

LC1-F400

132

50

LR9-F5357

500
700
2 x 600 MCM
147
250
280
355
335
335
150
200
400
500
LC1-F500

630
1000
3 x 600 MCM
200
335
375
400
450
450
250
300
600
800

800
1000
3 x 600 MCM
250
450
450
450
475
450
450
800
900

LC1-F630

LC1-F800

220

LR9-F5371
200

LR9-F5363
48

80

60

330

LR9-F7375

100

LR9-F7379

LR9-F5367

300

500

LR9-F5369

LR9-F7381

90

LT6-P0M005FM + LTC-CT001

150

1A
5A

380

630

630

780
1350
4 x 750 MCM

450
900
900
LC1-F780

NO NC

NO NC

NO NC

Built-in auxiliary contacts

750
1000
800
1250
2 x 80mm x 5mm55552 x 80mm x 5mm5555
220
280
400
500
425
590
500
600
560
670
530
530
LC1BL3

22

LC1BM3

22

1500
2000
3 x 100mm x 5mm5555
425
750
800
750
750
670
LC1BP3

22

1800
2750
4 x 100mm x 5mm5555
500
900
900
900
900
750
LC1BR3

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP
AC
DC

22

1A + LR2D1305
5A + LR2D1310
2750 A

2750 A

Front mounted
additional blocks

Coil Suffixes

Low Consumption

DC

DC

Hz

50/60

50*

60*

24 V
48 V
72 V
110 V
120 V
208 V
220 V
230 V
240 V
250 V
380 V
400 V
415 V
440 V

B7
E7
F7
G7
M7
P7
U7
Q7
V7
N7
R7

B5
E5
F5
M5
P5
U5
Q5
V5
N5
R5

B6 BD
E6 ED
SD
F6 FD
G6
L6
M6 MD
U6
UD
Q6
R6 RD*

1
2

4
3
2
1
-

LA1-KN20
LA1-KN11
LA1-KN02

1
2
3
4

LA1-KN40
LA1-KN31
LA1-KN22
LA1-KN13
LA1-KN04

2
1
-

1
2

NO NC NC NO

NO NC

LAD-N20
LAD-N11
LAD-N02

4
3
2
1
-

1
2
3
4

LAD-N40
LAD-N31
LAD-N22
LAD-N13
LAD-N04

NO

LAD-C22

LA1-DX20

2
2

2
1

1
2
1

40/400

FW
FW
MW
MW
MW

1
2

F
M
P
U
Q
V
N
R

QW
QW
QW
QW

Contactors

220/230
380/400
415 V
500 V
660/690
1000 V
200 V
230 V
460/480
575 V

V
V

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP

AC
DC
Low Consumption DC (< 2.4 W)
A1
A2

6
20
10
1.5
2.2
2.2
3
3
1.5
3
3
LC1-K06
LP1-K06
LP4-K06   3
10
01

Part number suffixes to specify power pole/


auxiliary contact configuration

01

004

008

0.11

Standard overload relays

0.16

LR2-K0301
0.36

0.54

1.2

9
25
10
2.2
4
4
5.5
5.5
2
5
7.5
LC1-D09
LC1-D09
LC1-D09  

12
25
10
3
5.5
5.5
7.5
7.5
3
7.5
10
LC1-D12
LC1-D02
LC1-D02

18
32
8
4
7.5
9
10
10
5
10
15
LC1-D18
LC1-D18
LC1-D18



25
40
6
5.5
1111
11
15
15
7.5
15
20
LC1-D25
LC1-D25
LC1-D25



32
50
6
7.5
15
15
18.5
18.5
10
20
30



40
60
3
11
18.5
22
22
30
10
30
30

50
80
3
15
22
25
30
33
15
40
40

65
80
3
18.5
30
37
37
37
20
50
50

80
125
2
22
37
45
55
45
30
60
60

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

10
01

3.7

10

LR2-K0320

0.25

LRD-02

0.4

0.63

LRD-03

LRD-04

LRD-05

1.6

LRD-06

2.5

LRD-07

25

LR2-K0307

30

10

LRD-10

12

18

LRD-08

LRD-14

23

LRD-21

48

65

LRD-3355

LRD-3359

LRD-3353

LRD-3357

23

11.5

40

LRD-3322

3.7

14

0.16

LRD-01

LR2-K0304

LR2-K0308

LR2-K0314

0.1
1.2

2.6

5.5

LR2-K0312
Class 10

0.8

1.8

17

0.36

LR2-K0301

LR2-K0305

LR2-K0307

Direct mounting on the contactor

0.23

LR2-K0302

LR2-K0304

Multifunction overload relays

10
01

12
20
10
3
5.5
5.5
4
4
3
7.5
10
LC1-K12
LC1-K12
LP4-K12   3

004
008

10

00

9
20
10
2.2
4
4
4
4
3
5
5
LC1-K09
LP1-K09
LP4-K09   3

32

37

55

32

LRD-32

50

70

80

104

LRD-3361

LRD-3365

LR2-K0312

12

LRD-12

18

LR2-K0321

5.5

LRD-16
8

LRD-22
13

0.2 A

17

LRD-35
25

30

LRD-3363

5A

LT6-P0M005FM

63

38

25 A

LT6-P0M025FM

(1) Except LC1-D115, LC1-D150


(2) Only LCI, LPI
(3) For LP4-D
For more information refer to publication 8502CT0101

80

Max. inductive current AC3


Max. resistive current AC1
Max. wire size

11

LA1-DY20

- 30s

NC

LAD-S2

NO

NO

0.1 - 3s
LAD-T0
1 - 30s LAD-T2
10 - 180s LAD-T4

NC

0.1 - 3s
LAD-R0
1 - 30s LAD-R2
10 - 180s LAD-R4

LAD-8N11(1)
LAD-8N20(1)
LAD-8N02(1)

*Except K

Maximum 3 phase
horsepower
ratings

NO

400

Maximum 3 phase
power ratings per
IEC 947-4

LA1-DZ40
LA1-DZ31

NC

NO NC

AC/DC AC

BL
EL
SL

NO

NO NO NC

115
250
250 MCM
30
55
59
75
80
75
40
75
100

150
250
250 MCM
40
75
80
90
100
90
50
100
125

LC1-D115

LC1-D150  7

LC1-D115

LC1-D150

60

100

LR9-D5367
LR9-D5369
90

150

AC

2
1
-

NO NC

115
175

30
55
59
75
80
65
30
40
75
100

150
200
3/
40
7755
80
90
100
65
40
50
100
125

LC1-F115

185
200
3/
55
9900
100
110
110
100
50
60
125
150

LC1-F150

30

LC1-F185

225
200
300 MCM
63
110
110
129
129
100
60
75
150
150

265
285
300 MCM
75
132
140
160
160
147
60
75
150
200

330
360
300 MCM
100
160
180
200
220
160
75
100
200
250

400
420
600 MCM
110
200
220
257
280
185
100
125
250
300

LC1-F225

LC1-F265

LC1-F330

LC1-F400

132

50

LR9-F5357

500
700
2 x 600 MCM
147
250
280
355
335
335
150
200
400
500
LC1-F500

630
1000
3 x 600 MCM
200
335
375
400
450
450
250
300
600
800

800
1000
3 x 600 MCM
250
450
450
450
475
450
450
800
900

LC1-F630

LC1-F800

220

LR9-F5371
200

LR9-F5363
48

80

60

330

LR9-F7375

100

LR9-F7379

LR9-F5367

300

500

LR9-F5369

LR9-F7381

90

LT6-P0M005FM + LTC-CT001

150

1A
5A

380

630

630

780
1350
4 x 750 MCM

450
900
900
LC1-F780

NO NC

NO NC

NO NC

Built-in auxiliary contacts

750
1000
800
1250
2 x 80mm x 5mm55552 x 80mm x 5mm5555
220
280
400
500
425
590
500
600
560
670
530
530
LC1BL3

22

LC1BM3

22

1500
2000
3 x 100mm x 5mm5555
425
750
800
750
750
670
LC1BP3

22

1800
2750
4 x 100mm x 5mm5555
500
900
900
900
900
750
LC1BR3

A
A
AWG
kW
kW
kW
kW
kW
kW
HP
HP
HP
HP
AC
DC

22

1A + LR2D1305
5A + LR2D1310
2750 A

2750 A

For heavy-duty applications,


contactors designed to switch
up to 2750 amps

Protection
and intelligence
combined

The LT6-P electronic multifunction protection relay is ideally


suited to high performance applications. It provides protection
for your motors in virtually any application or operating condition.

It enables automatic control of different methods of starting:

CV1 Contactors

For loads up to 950 amps inductive, 1000 amps resistive


Voltage up to 660 VAC or 440 VDC
Frequency up to 200 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

All the functionalities are programmable with parameters entered


locally or using a PC software.

It integrates into all the most complex automation systems


through its communication functions on UNITELWAY,
JBUS, MODBUS protocols.

Thermal Overload Relays from 6 to 2750 A

Manual Starter and Protector


The TELEMECANIQUE GV2 and GV3 devices incorporate a manual
disconnect, overload relay and instantaneous magnetic trip mechanism
in one compact device. They can be used as standalone manual
starters or to protect each branch circuit of a group motor installation.

in hard ambient conditions: high temperature, dust, humidity


with severe duty: fast operating cycles, use of DC injection braking.

cross-line (reversing or non-reversing)


star/delta
2-speed

Contactors and

Request document
8539CT9201R6/97

The LT3-S thermistor relay provides complementary protection


by direct measurement of the temperature of motors equipped
with PTC thermistor probes, for operation:

INTEGRAL Self-Protected Starters


TELEMECANIQUE INTEGRAL self-protected starters combine
circuit breaker, contactor and dual function overload relay for
coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated
protection. INTEGRAL starters can reduce panel space requirements
by 40 to 60%. 18A, 32A and 63A models are available.

Protect your motor


from damaging
over-temperatures

Request document
252OCT9501R6/97

Enclosed IEC Starters


D-Line starters and INTEGRAL self-protected starters are available
in metal NEMA Type 1 and 12 enclosures. These enclosed devices
utilize INSTAKIT components for the addition of cover mounted
pilot devices. INSTAKIT components are pre-wired control operator
kits that use a universal connector for quick, easy installation.
Request following documents
9502HO9401R0996 - INSTAKIT pre-wired starter access
9502HO9402R0996 - D-Line non-combination starters
9502HO9403R0996 - INTEGRAL starters
8502CT0101 - IEC SMCE contactors and starters
8502BR0102-TeSys-The New D-LINE

D-Line, K-Line and F-Line contactors and overload relays are the
largest selling motor starting and protection devices in the world. They
offer starting for motors up to 800 hp at 480 AC volts and switching
of resistive loads up to 1350 amps. They are UL-listed, CSA-certified
and CE-marked for use in North America and around the world.

CV3 Contactors

For loads up to 1800 amps inductive, 2750 amps resistive


Voltage up to 1000 VAC or 1500 VDC
Frequency up to 400 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

Visit the Square D web site


at www.SquareD.com

Order Number 8502BR0101


Printed in U.S.A.

2001 Schneider Electric


All Rights Reserved

Schneider Electric Brands

Get more with the worlds Power & Control specialist.

For heavy-duty applications,


contactors designed to switch
up to 2750 amps

Protection
and intelligence
combined

The LT6-P electronic multifunction protection relay is ideally


suited to high performance applications. It provides protection
for your motors in virtually any application or operating condition.

It enables automatic control of different methods of starting:

CV1 Contactors

For loads up to 950 amps inductive, 1000 amps resistive


Voltage up to 660 VAC or 440 VDC
Frequency up to 200 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

All the functionalities are programmable with parameters entered


locally or using a PC software.

It integrates into all the most complex automation systems


through its communication functions on UNITELWAY,
JBUS, MODBUS protocols.

Thermal Overload Relays from 6 to 2750 A

Manual Starter and Protector


The TELEMECANIQUE GV2 and GV3 devices incorporate a manual
disconnect, overload relay and instantaneous magnetic trip mechanism
in one compact device. They can be used as standalone manual
starters or to protect each branch circuit of a group motor installation.

in hard ambient conditions: high temperature, dust, humidity


with severe duty: fast operating cycles, use of DC injection braking.

cross-line (reversing or non-reversing)


star/delta
2-speed

Contactors and

Request document
8539CT9201R6/97

The LT3-S thermistor relay provides complementary protection


by direct measurement of the temperature of motors equipped
with PTC thermistor probes, for operation:

INTEGRAL Self-Protected Starters


TELEMECANIQUE INTEGRAL self-protected starters combine
circuit breaker, contactor and dual function overload relay for
coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated
protection. INTEGRAL starters can reduce panel space requirements
by 40 to 60%. 18A, 32A and 63A models are available.

Protect your motor


from damaging
over-temperatures

Request document
252OCT9501R6/97

Enclosed IEC Starters


D-Line starters and INTEGRAL self-protected starters are available
in metal NEMA Type 1 and 12 enclosures. These enclosed devices
utilize INSTAKIT components for the addition of cover mounted
pilot devices. INSTAKIT components are pre-wired control operator
kits that use a universal connector for quick, easy installation.
Request following documents
9502HO9401R0996 - INSTAKIT pre-wired starter access
9502HO9402R0996 - D-Line non-combination starters
9502HO9403R0996 - INTEGRAL starters
8502CT0101 - IEC SMCE contactors and starters
8502BR0102-TeSys-The New D-LINE

D-Line, K-Line and F-Line contactors and overload relays are the
largest selling motor starting and protection devices in the world. They
offer starting for motors up to 800 hp at 480 AC volts and switching
of resistive loads up to 1350 amps. They are UL-listed, CSA-certified
and CE-marked for use in North America and around the world.

CV3 Contactors

For loads up to 1800 amps inductive, 2750 amps resistive


Voltage up to 1000 VAC or 1500 VDC
Frequency up to 400 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

Visit the Square D web site


at www.SquareD.com

Order Number 8502BR0101


Printed in U.S.A.

2001 Schneider Electric


All Rights Reserved

Schneider Electric Brands

Get more with the worlds Power & Control specialist.

For heavy-duty applications,


contactors designed to switch
up to 2750 amps

Protection
and intelligence
combined

The LT6-P electronic multifunction protection relay is ideally


suited to high performance applications. It provides protection
for your motors in virtually any application or operating condition.

It enables automatic control of different methods of starting:

CV1 Contactors

For loads up to 950 amps inductive, 1000 amps resistive


Voltage up to 660 VAC or 440 VDC
Frequency up to 200 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

All the functionalities are programmable with parameters entered


locally or using a PC software.

It integrates into all the most complex automation systems


through its communication functions on UNITELWAY,
JBUS, MODBUS protocols.

Thermal Overload Relays from 6 to 2750 A

Manual Starter and Protector


The TELEMECANIQUE GV2 and GV3 devices incorporate a manual
disconnect, overload relay and instantaneous magnetic trip mechanism
in one compact device. They can be used as standalone manual
starters or to protect each branch circuit of a group motor installation.

in hard ambient conditions: high temperature, dust, humidity


with severe duty: fast operating cycles, use of DC injection braking.

cross-line (reversing or non-reversing)


star/delta
2-speed

Contactors and

Request document
8539CT9201R6/97

The LT3-S thermistor relay provides complementary protection


by direct measurement of the temperature of motors equipped
with PTC thermistor probes, for operation:

INTEGRAL Self-Protected Starters


TELEMECANIQUE INTEGRAL self-protected starters combine
circuit breaker, contactor and dual function overload relay for
coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated
protection. INTEGRAL starters can reduce panel space requirements
by 40 to 60%. 18A, 32A and 63A models are available.

Protect your motor


from damaging
over-temperatures

Request document
252OCT9501R6/97

Enclosed IEC Starters


D-Line starters and INTEGRAL self-protected starters are available
in metal NEMA Type 1 and 12 enclosures. These enclosed devices
utilize INSTAKIT components for the addition of cover mounted
pilot devices. INSTAKIT components are pre-wired control operator
kits that use a universal connector for quick, easy installation.
Request following documents
9502HO9401R0996 - INSTAKIT pre-wired starter access
9502HO9402R0996 - D-Line non-combination starters
9502HO9403R0996 - INTEGRAL starters
8502CT0101 - IEC SMCE contactors and starters
8502BR0102-TeSys-The New D-LINE

D-Line, K-Line and F-Line contactors and overload relays are the
largest selling motor starting and protection devices in the world. They
offer starting for motors up to 800 hp at 480 AC volts and switching
of resistive loads up to 1350 amps. They are UL-listed, CSA-certified
and CE-marked for use in North America and around the world.

CV3 Contactors

For loads up to 1800 amps inductive, 2750 amps resistive


Voltage up to 1000 VAC or 1500 VDC
Frequency up to 400 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

Visit the Square D web site


at www.SquareD.com

Order Number 8502BR0101


Printed in U.S.A.

2001 Schneider Electric


All Rights Reserved

Schneider Electric Brands

Get more with the worlds Power & Control specialist.

For heavy-duty applications,


contactors designed to switch
up to 2750 amps

Protection
and intelligence
combined

The LT6-P electronic multifunction protection relay is ideally


suited to high performance applications. It provides protection
for your motors in virtually any application or operating condition.

It enables automatic control of different methods of starting:

CV1 Contactors

For loads up to 950 amps inductive, 1000 amps resistive


Voltage up to 660 VAC or 440 VDC
Frequency up to 200 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

All the functionalities are programmable with parameters entered


locally or using a PC software.

It integrates into all the most complex automation systems


through its communication functions on UNITELWAY,
JBUS, MODBUS protocols.

Thermal Overload Relays from 6 to 2750 A

Manual Starter and Protector


The TELEMECANIQUE GV2 and GV3 devices incorporate a manual
disconnect, overload relay and instantaneous magnetic trip mechanism
in one compact device. They can be used as standalone manual
starters or to protect each branch circuit of a group motor installation.

in hard ambient conditions: high temperature, dust, humidity


with severe duty: fast operating cycles, use of DC injection braking.

cross-line (reversing or non-reversing)


star/delta
2-speed

Contactors and

Request document
8539CT9201R6/97

The LT3-S thermistor relay provides complementary protection


by direct measurement of the temperature of motors equipped
with PTC thermistor probes, for operation:

INTEGRAL Self-Protected Starters


TELEMECANIQUE INTEGRAL self-protected starters combine
circuit breaker, contactor and dual function overload relay for
coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated
protection. INTEGRAL starters can reduce panel space requirements
by 40 to 60%. 18A, 32A and 63A models are available.

Protect your motor


from damaging
over-temperatures

Request document
252OCT9501R6/97

Enclosed IEC Starters


D-Line starters and INTEGRAL self-protected starters are available
in metal NEMA Type 1 and 12 enclosures. These enclosed devices
utilize INSTAKIT components for the addition of cover mounted
pilot devices. INSTAKIT components are pre-wired control operator
kits that use a universal connector for quick, easy installation.
Request following documents
9502HO9401R0996 - INSTAKIT pre-wired starter access
9502HO9402R0996 - D-Line non-combination starters
9502HO9403R0996 - INTEGRAL starters
8502CT0101 - IEC SMCE contactors and starters
8502BR0102-TeSys-The New D-LINE

D-Line, K-Line and F-Line contactors and overload relays are the
largest selling motor starting and protection devices in the world. They
offer starting for motors up to 800 hp at 480 AC volts and switching
of resistive loads up to 1350 amps. They are UL-listed, CSA-certified
and CE-marked for use in North America and around the world.

CV3 Contactors

For loads up to 1800 amps inductive, 2750 amps resistive


Voltage up to 1000 VAC or 1500 VDC
Frequency up to 400 Hz
Maximum of 5 NO or NC power poles
Maximum of 7 NO or NC auxiliary poles

Visit the Square D web site


at www.SquareD.com

Order Number 8502BR0101


Printed in U.S.A.

2001 Schneider Electric


All Rights Reserved

Schneider Electric Brands

Get more with the worlds Power & Control specialist.