http://223.254.254.244/til/index.html
In the user name field, put your name and leave the Default path unchanged
Click start and wait for username/password prompt
Username: nodeb
Password: nodeblnx
Click OK and you will be logged in to the nodeB
In the I&C menu, chose Change I&C parameters, you will be taken to the parameters window:
First thing: make sure the Fallback to previous I&C data is set to DEACTIVATE and that the Serial Number
matches the serial number found on the chassis sticker
In the BACKHAUL tab, select Gigabit Ethernet:
In the Ethernet tab, enter the OAM VLAN ID as per the design sheet and select the appropriate MDA
port:
Check the CCM board to see which port is used to connect to the network. In this example, MDA port 1 is
used.
In the IP Parameters tab, enter the nodeBs OAM IP, the OMC IP, the OAM Sub-network mask and the
default gateway as per the design sheet and leave all other parameters at their default:
End of procedure