Professional Documents
Culture Documents
Security Level
NodeB Service IP
RNC IP
2. LST OMCH
2015-06-19
Page1, Total8
Document Title
Security Level
NodeB OAM IP
3. LST VLANMAP
2015-06-19
Page2, Total8
Document Title
Security Level
NodeB Gateway IP
4. PING
a.
2015-06-19
Service IP
Huawei Proprietary - Restricted Distribution
Page3, Total8
Document Title
Security Level
NodeB Service IP
NodeB Gateway IP
ii. RNC
2015-06-19
Page4, Total8
Document Title
Security Level
RNC IP
NodeB Service IP
b. M2000 (OAM)
2015-06-19
Page5, Total8
Document Title
Security Level
NodeB OAM IP
M2000 IP = 10.164.20.3
2015-06-19
Page6, Total8
Document Title
Security Level
2015-06-19
Reply --> Please check the Ethernet cable from WMPT to transmission device. Try change to a fabricated cable and make sure its blinking
Page7, Total8
Document Title
Security Level
normally.
b. RTO --> Please contact transmission engineer.
From: Fanlei
Sent: Tuesday, November 20, 2012 7:15 PM
To: Elvyra Sari; so chai woei; Chenlimin (Clm); Chenjunqiang
Cc: Wandra Mardyendri; Lvjing (William); Wangxianghua; Bernardus K; Fang Di Jiang; Fuguoqiang; Reynaldo Adriano; Rian Ramdhan (B); Zaki Mujahid
Subject: IP transmission trouble shoot, ////: 3G KPI Performance Report_Huawei 19 November 2012
Dear Vyra,
For the SCTP link Fault or congestion, 99% is transmission part problem.
There are 2 way to prove it is transmission problem, please read the guideline first
1: check the history alarm occur times/hour, do the ping test in the same times,
2: Active IPPM function, then we can collect IP transmission quality from the OSS statistic
(please just active for the problem site only, and deactivate after trouble shooting complete)
To Pak Socaiwei ,
Need you help together with us to trouble shoot the IP transmission tomorrow,
After we familiar with the work flow/method, we check this issue directly .
Thanks.
2015-06-19
Page8, Total8