Professional Documents
Culture Documents
Project no.:
Made by:
1011
DGT
Date:
May 27, 2015
Page no.:
KN
KN/m
MPa
MPa
mm
mm
mm
pcs
mm
pcs
mm
Beam
CALCULATION:
v = V / (bv d)
v = 300.0x10 / (250 x 600) = 2.000MPa
(Eq. 3)
(Table 3.8)
(Table 3.7)
As = 3(20/4) = 942.5mm
vc = [0.79/gm] [100As/bv d]^ [400/d]^ [fcu/25]^
vc = [0.79/1.25] [(100x942.48)/(250x600)]^ [400/600]^ [35.0/25]^
vc = 0.606MPa
Asv = 2(12/4) = 226.2mm
v - vc = 2.000 - 0.606 = 1.394 > 0.400 , use 1.394
s = Asv(fyv/s) / [bv(v - vc)]
s = 226.19(250/1.15) / (250.0 x 1.394) = 141mm < (smin = 0.75d = 450mm)
Provide 2 legs T12 @ 125mm provide for distance of 1000mm then
nominal links 2 legs T12 @ 450mm