@ weseronezane
LP Any Engineering
SPECIFICATION FOR BEDD
DEMONSTRATION H2 PSA oar isaue: ont 12 201
Job No. : A11226 Page : 40 of 47
5.1.5.2.
5.1.5.3.
5.1.5.4.
normally
d) Screw compressors, conforming to API Standard 619 (latest edition), can be
specified in special cases where found to have an operating, economic or
maintenance advantage over other choict's. Screw compressors shall not be
spared but specifications shall be given for a spare rotor. Driver selection shall
be as for centrifugal compressors.
COMPRESSOR CONTROLS
Compressor control (interlocks and shutdown) shall be PLC based and located
incontrol room. PLC make shall be standardized for entire unit
Only start-up operation is carried out from local panel and normal control from
central control room.
COMPRESSOR SEALS
Dry gas seals are preferred.
irectional and inter-changeability in Drive-end and driven
end to be considered
Unit designers shall address issues such «as common or individual compressor
suction and interchange KODs, common or individual compressor
inter-stage coolers and surge control etc. as part of unit operability and cost
saving factors.
5.2, PIPING
Engineering Design Basis shall define the detailed design requirements for