You are on page 1of 4

MG6250 - Magellan 2-partition 64-zone

Wireless Console with GPRS/GSM


Whats New V1.5
Overview

Updated and new programming sections


Special EN 50131 defaults
System timers for EN 50131 compliancy
Setting EN 50131option defaults from the console

The following programming sections have been added to V1.5. They may not be included in any manuals, therefore use this document in conjunction with the
MG6250 Console Section Programming Guide. The newest additions in the following tables are depicted with a double-lined border.

Updated and New Programming Sections


Special Alarm Report Codes
Section

[1658]

Description

Data

Zone shutdown

Duress

Keypad lockout

Paramedical

Special Report Codes


Section

[1702]

Description

Data

Installer login

Installer logout

Delinquency

Fail to arm

Wireless Remote Trouble/Restore Report Codes


Section

[1741]

Description

Data

Wireless remote battery trouble

Wireless remote battery trouble restore

Future Use

Future Use

General Options
Section

[2002]

Page 1

Option

Description

OFF

ON

Disabled

Volume boost on entry/exit

Volume boost in speaker phone mode

Check-in supervision time

RF jamming supervision

Disabled

Daylight savings time

Disabled

Trouble latch

Disabled

Need code to view troubles/events

Disabled

Bell squawk when installer in

Disabled

Disabled
24 Hrs.

PARADOX.COM

Enabled

Enabled

80 minutes
Enabled

Enabled

Enabled

Enabled

Enabled

MG6250-EW02 09/2012

Dialer Options
Section

Option

[2009]

OFF

Description

ON

Enabled

Restrict arming when zone opens during exit delay*

Disabled

Ack trouble(s) before arming

Disabled

Enabled

Future use

Future use

Future use

Future use

Future use

Future use

* Stays open at the end of exit delay

System Timers
Section

[2020]
[2021]
[2022]
[2023]
[2024]
[2025]
[2026]
[2027]
[2028]
[2029]
[2030]
[2031]
[2032]
[2033]
[2034]
[2035]
[2036]
[2037]
[2038]
[2039]
[2040]
[2041]
[2042]
[2043]
[2044]
[2048]
[2049]

Description

Entry delay 1
Entry delay 2
Intellizone delay
Recent closing delay
Auto-zone shutdown counter
Remote lock delay
Delinquency delay
Power failure report delay
Pre-alarm delay (StayD)
Re-arm delay (StayD)
Entry delay audio selection
Exit delay audio selection
Number of rings
Answering machine override delay
TLM fail timer
Delay alarm transmission
Delay between dialling attempts
Lowest rate (primary communication)
Auto-test report
Auto-test report time
GSM network failure delay
GPRS bandwidth saver delay
EN 50131 fail to communicate timer
Keypad lockout
Keypad lockout duration
Trouble shutdown
Panic shutdown

Data (value from 000 to 255)

Default Setting

____/____/____ seconds
____/____/____ seconds
____/____/____ seconds (minimum 10 seconds)
____/____/____ seconds
____/____/____ times
____/____/____ seconds
____/____/____ days
____/____/____ minutes
____/____/____ seconds
____/____/____ seconds
____/____/____ (000 to 006*)
____/____/____ (000 to 006*)
____/____/____ rings
____/____/____ seconds
____/____/____ seconds
____/____/____ seconds
____/____/____ seconds (maximum 130 seconds)
____/____ (01=landline; 02 = GSM)
____/____/____ days
____/____:____/____
____/____/____ seconds
____/____/____ minutes
____/____/____ seconds
____/____/____ attempts
____/____/____ minutes
____/____/____ times
____/____/____ times

045 sec.
045 sec.
045 sec.
Disabled
005 times
020 sec.
Disabled
015 min.
015 sec.
005 sec.
005
002
008 rings
030 sec.
032 sec.
Disabled
020 sec.
Disabled
Disabled
Disabled
032 sec.
Disabled
0 sec.
0 attempts
Report only
0
0

* 000 = No tone; 001 = Beeping; 002 = Countdown; 003 = Tonality 1; 004 = Tonality 2; 005 = Tonality 3; 006 = Tonality 4

Special EN 50131 Defaults


General Options
Section

[2000]

Option

Description

OFF

ON

6 Digits

4 Digits

Audible trouble warning (except AC power failure)

Disabled

AC power failure warning

Disabled

Lock master code

Disabled

Enabled

4
5

Console tamper supervision

Access code length

2
3

Code necessary to bypass zones

Partition

Future use

MG6250-EW02 09/2012

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

PARADOX.COM

Enabled

Enabled

Page 2

Section

[2002]

Option

OFF

Description

ON

Enabled

Disabled

Volume boost on entry/exit

Volume boost in speaker phone mode

Check-in supervision time

RF jamming supervision

Daylight savings time

Trouble latch

Need code to view troubles/events

Bell squawk when installer in

Disabled
24 Hrs.

Disabled

Enabled
80 minutes
Enabled
Enabled

Disabled
Disabled

Enabled

Disabled

Enabled

Disabled

Enabled

Arming/Disarming Options
Section

[2003]

Option

OFF

Description

Bell squawk when arming/disarming with remote control

Stay arming switches to force stay arming

Sleep arming switches to force sleep arming

Full arming switches to force full arming

ON

Enabled

Disabled
Disabled

Enabled

Disabled
Disabled
Always

Report system disarming

One-touch stay arming

Disabled

One-touch sleep arming

Disabled

One-touch full arming

Disabled

Enabled
Enabled
After alarm
only
Enabled

Enabled

Enabled

Wireless Module Options


Section

Option

OFF

Description

Future use

Report zone restore

On bell cut-off

Tamper recognition options (console tamper follows this option)

3&4

[2004]

On zone closure

Disabled

OFF

OFF

Trouble only

OFF

ON

Disarmed: Trouble only


Armed: Follow zones alarm type

ON

OFF

Disarmed: Audible alarm


Armed: Follow zones alarm type

ON

ON

Disabled

Enabled

Generate tamper trouble if detected on bypassed zone


Wireless transmitter supervision option

6&7

ON

Disabled

OFF

OFF

Trouble only

OFF

ON

Disarmed: Trouble only


Armed: Follow zones alarm type

ON

OFF

Disarmed: Audible alarm


Armed: Follow zones alarm type

ON

ON

Disabled

Enabled

Generate supervision trouble if detected on bypassed zone

Dialer Options
Section

[2009]

Page 3

Option

OFF

Description

ON

Disabled

Enabled

Future use

Future use

Future use

Future use

Future use

Future use

Restrict Arming when zone opens during exit delay

Ack trouble(s) before arming

PARADOX.COM

Disabled

Enabled

MG6250-EW02 09/2012

System Timers
Section

[2020]
[2021]
[2022]
[2023]
[2024]
[2025]
[2026]
[2027]
[2028]
[2029]
[2030]
[2031]
[2032]
[2033]
[2034]
[2035]
[2036]
[2037]
[2038]
[2039]
[2040]
[2041]
[2042]
[2043]
[2044]
[2048]
[2049]

Description

Entry delay 1
Entry delay 2
Intellizone delay
Recent closing delay
Auto-zone shutdown counter
Remote lock delay
Delinquency delay
Power failure report delay
Pre-alarm delay (StayD)
Re-arm delay (StayD)
Entry delay audio selection
Exit delay audio selection
Number of rings
Answering machine override delay
TLM fail timer
Delay alarm transmission
Delay between dialling attempts
Lowest rate (primary communication)
Auto-test report
Auto-test report time
GSM network failure delay
GPRS bandwidth saver delay
EN 50131 Fail to communicate timer
Keypad lockout
Keypad lockout duration
Trouble shutdown
Panic shutdown

Data (value from 000 to 255)

Default Setting

____/____/____ seconds
____/____/____ seconds
____/____/____ seconds (minimum 10 seconds)
____/____/____ seconds
____/____/____ times
____/____/____ seconds
____/____/____ days
____/____/____ minutes
____/____/____ seconds
____/____/____ seconds
____/____/____ (000 to 006*)
____/____/____ (000 to 006*)
____/____/____ rings
____/____/____ seconds
____/____/____ seconds
____/____/____ seconds
____/____/____ seconds (maximum 130 seconds)
____/____ (01=landline; 02 = GSM)
____/____/____ days
____/____:____/____
____/____/____ seconds
____/____/____ minutes
____/____/____ seconds
____/____/____ attempts
____/____/____ minutes
____/____/____ times
____/____/____ times

045 sec.
045 sec.
045 sec.
Disabled
005 times
020 sec.
Disabled
015 min.
015 sec.
005 sec.
005
002
008 rings
030 sec.
032 sec.
Disabled
020 sec.
Disabled
Disabled
Disabled
032 sec.
Disabled
120 sec.
5 attempts
15 minutes
5 times
10 times

* 000 = No tone; 001 = Beeping; 002 = Countdown; 003 = Tonality 1; 004 = Tonality 2; 005 = Tonality 3; 006 = Tonality 4

System Timers for EN 50131 Compliancy


System timers for EN 50131 compliancy must respect the following criteria:
[2020] - [2021] Entry delay1: maximum value is 45 seconds
[2024] Auto-zone shutdown counter: value must be between 3 and 10 times
[2027] Power failure report delay: maximum value is 60 minutes
[2042] EN50131 FTC timer: maximum value is 120 seconds
[2043] Number of invalid codes before lockout value: must be between 3 and 10
[2044] Keypad lockout duration: minimum value is 2 minutes
[2048] Trouble shutdown: value must be between 3 and 10 times
[2049] Panic shutdown: value must be between 3 and 10 times
[2111] - [2121] Bell cut-off delay: must be between 90 seconds and 15 minutes

Setting EN 50131 Option Defaults from the Console


EN 50131 option defaults can be set from the console under advanced section [9003] or the installer menu.

08-System
08-SYSTEMSetup
SETUP
next
exit
ok
ok
next
exit

MG6250-EW02 09/2012

Enter a Code

11-EN50131
back

ok

PARADOX.COM

next

Set EN50131?
exit

ok

exit

Page 4