Professional Documents
Culture Documents
WHEN
THE
CHARGE
HOLDS
DATA
AND
INSTRUCTIONS FOR FURTHER MANIPULATION
ELECTRIC
LOCOMOTIVE
REFERS
POWERPLANT MOUNTED ON WHEELS
TO
RATION
RADIUS
OF
OF
NEAREST NEIGHBOR
1ATOM/CELL
NEAREST NEIGHBOR
4ATOM/CELL
NEAREST NEIGHBOR
2ATOM/CELL
FOR
FOR
FOR
SC
FCC
12
BCC
REYNOLDS
NUMBER
DIMENSIONLESS
NUMBER THAT IS USED TO DESCRIBED BY
VISCOSITY OF FLUID
ELECTRIC
ARC
FURNACE
HEAT
IS
GENERATED BY ELECTRICAL ARCS FROM THREE
ELECTRODES EXTENDING THE WALL DOWN INTO
ENERGY CHARGE SPACE IN FURNACE
MOST
COMMON
REINFORCEMENT FOR POLYMER COMPOSITES
RATE
OF
RETURN
MEASURE
OF
EFFECTIVENESS OF INVESTMENT OR CAPITAL
MAGNETIC
QUANTITY
WHAT
IS
THE
CHANGE
IN
THE
GRAVITATIONAL ATTRACTION BETWEEN AN
ORBITING OBJECT AND THE EARTH IF THE
DISTANCE BETWEEN THEM IS DOUBLED? =
ONE-FOURTH
MODULUS OF RIGIDITY OF A STEEL
MEMBER DEFINED AS THE UNIT SHEAR
STRESS
DVIDED
BY
THE
UNIT
SHEAR
DEFORMATION
THIN
HOMOGENOUS
METALLIC
PLANE
CONTAINING
A
HOLE
IS
HEATED
SUFFICIENTLY TO CAUSE EXPANSION IS
LINEAR, THE AREA OF THE HOLE WILL?
=INCREASE AT THE SAME RATE AS THE AREA OF
METAL INCREASES
IN A LONG COLUMN (SLENDERNESS RATIO
IS >160) WHICH OF THE FOLLOWING HAS
THE
GREATEST
INFLUENCE
ON
ITS
TENDENCY
TO
BUCKLE
UNDER
A
COMPRESSIVE LOAD. =THE LENGTH OF THE
COLUMN
THE AREA OF THE SHEAR DIAGRAM OF A
BEAM BETWEEN ANY TWO POINTS ON THE
BEAM IS EQUAL TO: - CHANGE IN MOMENT
BETWEEN TWO POINTS
POISSONS RATIO IS PRINCIPALLY USED IN:
STRESS-STRAIN
RELATIONSHIP
WHERE
STRESSES ARE APPLIED IN MORE THAN ONE
DIRECTION
THE STRESS IN AN ELASTIC MATERIAL IS: PROPORTIONAL TO THE DISPLACEMENT OF THE
MATERIAL ACTED UPON BY THE FORCE
BACK-UP RESERVE THE ABILITY TO RESPOND
TO A RE-DISPATCH PERFORMED SYSTEM
OPERATOR HAVING A TRADING INTERVAL ON
EITHER A REGULAR OR AD HOC BASIS
LUMINOUS FLUX - THE RATE OF PASSAGE OF
RADIANT ENERGY EVALUATED BY REFERENCE TO
THE LUMINOUS SENSATION PRODUCED
DURING
AN
ADIABATIC,
INTERNALLY
REVERSIBLE PROCESS, WHAT IS TRUE
ABOUT THE CHANGE IN ENTROPY? = IT IS
ALWAYS ZERO
METASTABLE STATE WHEN SYSTEM IS IN
EQUILIBRIUM
FIELD
INTENSITY
VECTOR
UNITY IN TWO
READING WILL BE
765kV
STATION
IS
-
L
C
- SURGE IMPEDANCE
WYE-WYE
POWER
TRANSFORMER ARE PROTECTED HAVING ____
CANDELA LUMINOUS INTENSITY OF A LAMP
EXPRESSED IN _____
0.7V BARRIER POTENTIAL FOR A SILICON
DIODE AT 25C
CARBON BRUSHES OF DC MACHINE ARE
USUALLY MADE OF ____
LOCAL
ACTION
IMPURITIES
IN
AN
ELECTROLYTE CAN CAUSE AN INTERNAL SHORT
CIRCUIT CALLED _____
3 MINIMUM NUMBER OF UNBALANCED WATT
METER
PERMEANCE
CONDUCTANCE
IS
ANALOGOUS
TO
AREA
L
C
ALTERNATING
CURRENT NATURE
CURRENT FLOWING IN ARMATURE OF
MACHINE
R<2
OF
COPPER
COATING
METAL
UNGROUNDED
WATER
PIPE
SUPPLEMENTED BY ADDITIONAL ELECTRODE
IS
THE CRITICAL POINT FOR A MIXTURE OCCURS WHEN VAPOR & LIQUID HAVE A FORM
THAT IS STABLE FOR A CRITICAL TEMPERATURE
AND CRITICAL PRESSURE, IT IS BOTH A LIQUID
AND A VAPOR WITH NO BOUNDARIES AND A
UNIFORM COMPOSITION (SINGLE FORM)
THAT
ARE
POLYMERS
WHICH
FAVOR
CRYSTALLIZATION
HOW
DOES
AN
ADIABATIC
PROCESS
COMPARE TO AN ISENTROPIC PROCESS?
HEAT TRANSFER = 0; ISENTROPIC = REVERSIBLE
WHICH
IS
NOT
A
CARNOT
CYCLE:
REVERSIBLE CONSTANT HEAT ADDITION
THAT
GROUNDED
CONDUCTOR
LARGER THAN 14mm, MARKING IT AS
TERMINATOR
25AMPERE
IS
NOT
A
STANDARD
CLASSIFICATION FOR BRANCH CIRCUIT
55A AMPACITY NOT BE LESS THAN THAT OF
SERVICE ENTRANCE CONDUCTORS WHERE
CONDUCTORS CARRY TOTAL LOAD SUPPLIED BY
SERVICE ENTRANCE CONDUCTOR
5% - TOTAL VOLTAGE DROP IN BOTH FEEDERS
0.50 COMPUTATIONS FUNCTION OF AMPERE
SHALL BE PERMITTED TO BE DROPPED
3000mm OPEN CONDUCTORS ON INSULATORS
SHALL BE COVERED WHEN THEY ARE WITHIN
____ OF THE BUILDING
AN
IDEAL
GAS
IS
COMPRESSED
ISOTHERMALLY, THE ENTHALPY CHANGE IS ZERO
HOLLOW EXPANDED ARE CONDUCTORS
USED ON HIGH VOLTAGE TRANSMISSION LINES,
WHEN IN ORDER TO REDUCE CORONA LOSS, IT
IS DESIRABLE TO INCREASE THE OUTSIDE
DIAMETER WITHOUT INCREASING THE AREA
BEYOND THAT NEEDED FOR MAXIMUM LIFE
ECONOMY
TRANSITION ELEMENTS ELEMENTS WHICH
GENERALLY EXHIBITS MULTIPLE OXIDATION
STATE
WEAK ELECTROLYTE A SUBSTANCE THAT
PARTLY IONIZED IN SOLUTION
CALCINATION HEATING OF AN ORE TO BRING
ABOUT ITS DECOMPOSITION OF VOLATILE
PRODUCT
EARTH GROUND
EXTENDING TO ___
FAULT
CURRENT
PATH
A POLYMER WITHOUT
WITHOUT BLENDING WITH
RATE
OF
RETURN
MEASURE
OF
EFFECTIVENESS OF INVESTMENT OF CAPITAL
A
HALOGEN
HAS
AN
ELECTRONIC
CONFIGURATION OF 1S2 2S2 2P6 3S2 3P5
THE
IMPURITY
ATOMS
IN
A
SEMICONDUCTOR REDUCES THE ENERGY
GAP
OF
AS
AS
A
THERMISTOR
HAS
A
NEGATIVE
TEMPERATURE COEFFICIENT OF RESISTANCE
MOST
3
4
kW MINIMUM
BRANCH CIRCUIT
FENCE - HIGH VOLTAGE EQUIPMENT SHALL BE
SEPARATED FROM ENERGIZED COMPONENT BY
MEANS OF ____
DEPARTMENT OF FINANCE BOARD OF
TRUSTEES OR BOARD MEMBERS OF TRANSCO
15MINUTES FAST START DEFINED AS THE
CAPABILITY OF GENERATING UNIT WITHIN ___
VOLTAGE DIP ANOTHER TERM OF VOLTAGE
SAG
SHEAR
STRESS
AND
ANGULAR
DEFORMATION RATE - ABSOLUTE VISCOSITY
OF FLUID VARIES WITH MEASURE AND DEFINED
AS A FUNCTION
STEEL HAS LOWER CARBON CONTENT
MAIN DIFFERENCES BETWEEN IRON AND STEEL
IS THAT ___
ANNEALING IS NOT
STRENGTHENING STEEL
THE
PROCESS
OF
JOINT
COMMISSION
CONGRESSIONAL
POWER
MAINFRAME
COMPUTERS
GENERAL
PURPOSE
COMPUTERS
USED
IN
LONG
CENTRALIZED APPLICATIONS WHICH RUNNING
SIMULTANEOUSLY
C-LANGUANGE
LANGUANGE
BRAKE
IN
UNDERGO
IN
OXIDATION-REDUCTION
SIMPLE
YET
POWERFUL
OXIDANT
REDOX
OR
FOR
AND
WATTMETER
UNBALANCE
DEFINED
AS
RMS
IS
NOT
TO
IS
WHEN
INCREASE
EQUIPMENT
ENCLOSURE
NUMBERS CONNECTED
MUST
SURGE
NUMBER
OF
TRANSFORMER
WELDING
RESISTANCE
BONDING
REAR
TRANSFORMER
CONNECTOR BE PLACED
3000VA
MINIMUM
GROUNDING LOAD
APPLIANCE
RATING
AND
OF
SECTION 33
REQUIRED
ARTICLE
IV
PERSONNEL
SUBSTATION ANY
SEPARATE
PLACE
TRANSMISSION
BUILDING, ROOM,
CONNECTED
OR
TO
SERIES MOTOR
STARTING TORQUE
SUITABLE
FOR
HIGH
FOR
THE
SERIES
RLC
CIRCUIT
AT
RESONANCE THE CURRENT AMPLITUDE IS
MAXIMUM
FOR
A
FIXED
VOLTAGE
AMPLITUDE AND POWER FACTOR IS ZERO
1.732VL IL P.F POWER IN A THREE PHASE
DELTA SYSTEM WITH BALANCED LOAD
1.732I - LINE CURRENT
CONNECTED SYSTEM
IN
DELTA
IN
TWO
WATTMETER
METHOD,
THE
READING OF THE WATTMETER WILL BE
IDENTICAL WHEN POWER FACTOR IS ZERO
LENGTH, CROSS-SECTIONAL AREA, NATURE
OF MATERIAL AFFECTS THE RESISTANCE OF
THE CONDUCTOR
FREQUENCY AND ARMATURE
AFFECTS THE SPEED OF AC MOTOR
POLE
MINIMUM
SIZE
UNDERGROUND SERVICE LATERAL CONDUCTOR
PLATE ELECTRODE SHALL BE INSTALLED OF
NOT LESS THAN 750mm BELOW THE
SURFACE OF THE SOIL
WHERE MULTIPLE ROD, PIPES OR PLATE
ELECTRODES ARE INSTALLED TO MEET
MAXIMUM
OF
25
RESISTANCE
TO
GROUND, THEY SHALL NOT BE LESS THAN
1800mm APART
80% - BRANCH CIRCUIT PERMISSIBLE LOAD
THE MAIN PURPOSE OF BONDING JUMPER
IS TO CONNECT EQUIPMENT GROUNDING
CONDUCTORS AND SERVICE DISCONNECT
IS
USE
OF