130 ANCHOR BOLT TECHNICAL DATA THE ANCHOR BOLT PLAYS AN IMPORTANT PART AS PRIMARY ELEMENT IN THE MACHINE - ‘TO - FOUNDATION CONNECTION. THE FUNCTION OF THE BOLT IS TO TRANSFER LOAD FROM THE, MACHINE TOOL BASE TO THE FOUNDATION. TO. DO THIS ,THE ANCHOR BOLT MUST BE FIRMLY ANCHORED INTO THE CONCRETE FOUNDATION, AND CAPABLE OF SUSTAINING SIGNIFICANT TENSION LOADINGS IN THE UPWARD DIRECTION. SINCE CONCRETE ISNOTCAPABLE OF WITH- STANDING TENSILE LOADINGS, THE ANCHOR, BOLT MUST RESOLVE THE TENSILE LOAD AP- PLIED TOITINTO COMPRESSION LOADING IN THE FOUNDATION. THE JAKEBOLT TRANSFERS THE TENSILE LOAD IN THE UPWARD DIRECTION ON THE FOUN- DATION THROUGH THE BEARING PLATE. INTHE VECTOR BOLT , THE WEDGE SHAPE DESIGN ON THE BOTTOM OF THE BOLT ACCOM- PLISHES THE SAME FUNCTION WITH EITHER THE JAKEBOLT OR VECTOR BOLT, THE MEANS THROUGH WHICH CONCRETE FAILURE OCCURS INVOLVES THE SHEARING- OUT CONE SHAPED SECTION. SEE FIGURES 1 & 2. IT CAN BE PROVEN MATHEMATICALLY THAT, ‘THEMOST IMPORTANT FACTOR IN CALCULATING LOAD ON AN ANCHOR BOLT IS THE DEPTH OF THE EMBEDMENT ONCE. THE DEPTH OF INBEDMENT IS KNOWN , IT IS POSSIBLE TO CALCULATE THE MAXIMUM LOAD WHICH MAY BE APPLIED TO AN ANCHOR BOLT. INPRACTICE,ITISMORE DESIRABLETO HAVE, ‘THE ANCHOR BOLT FAIL BEFORE THE CONICAL, SECTION IS PULLED FROM THE CONCRETE. IN THE CASE OF THE JAKEBOLT, THIS FACILITATES, ‘THE REPLACEMENT OF THE STUD WITH A MINI- MUM OF PROBLEMS. WITH THE VECTOR BOLT, THE FOUNDATION DAMAGE WILL BE LIMITED SO THAT ‘THEBOLTCANSIMPLY BE CORED OUT AND ANEW, ONE GROUTED IN ITS PLACE. INORDERTO ASSURE THAT THE BOLT FAILS, FIRST , IT IS NORMAL TO DESIGN THE ANCHOR IMBEDMENT DEPTH USING A FACTOR OF 2 ON ‘THE ALLOWABLE SHEAR-STRESS APPLIED TO THE SURFACE OF THE CONE. KNOWING THE CROSS, SECTIONAL AREA OF THE BOLT AND THE ULTI- MATE TENSILE STRENGTH OF THE MATERIAL FROM WHICH IT IS MADE, IT IS POSSIBLE TO CAL- CULATE THE LOAD AT WHICH THE BOLT WILL FAIL, HIGHER TENSILE VECTOR BOLTS REQUIRE DEEPER EMBEDMENTS TO DEVELOP FULL HOLDING POWER BEFORE CONCRETE FAILURE. ‘THE USE OF REINFORCING STEEL IN ANY FOUN- DATION , INCREASES THE FACTOR OF SAFETY AGAINST THE SHEAR CONE TYPE FAILURE AND IS HIGHLY RECOMMENDED. ALSO, THE PLACEMENT OF THE ANCHOR BOLT ‘SHOULD BE FAR ENOUGH AWAY FROM ANY WALLS. TO PERMIT AFULL SHEAR CONE TO DEVELOP .FAIL- URE TO DO THIS CAN RESULT IN SERIOUS REDUC- TION OF THE ANCHOR BOLTS' HOLDING POWER. A GOOD GUIDE IS TO HAVE THE ANCHOR BOLT NO CLOSER TO THE EDGE THAN 1-1/2 TIMES THE EN- BEDMENT DEPTH. IN THE CASE OF THE VECTOR BOLT ,THE USE OF GROUT TENDS TO INCREASE THE FACTOR OF SAFETY., SINCE GROUT IS A VERY HIGH STRENGTH MATERIAL COMPARED TO CONCRETE.THE GROUT SERVES THE FUNCTION OF SPREADING THE HIGH UNIT LOADS SEEN NEAR THE ANCHOR BOLT FLUTES OVER A MUCH LARGER AREA. FIGURE 2 : VECTOR BOLT SHEAR CONE hw ANCHOR BOLT TECHNICAL DATA HEAVY DUTY JAKEBOLTS : MATERIAL 90,000 PSI EI MENT FAILURE LOAD FOR - JAKEBOLTS [ROMINAL [FAILURE LOAD [CALCULATED [RECOMMENDED [size Les. hana DEPTH unum DEPTH Te 13,500 4.0" a5” e cociaemeee eemeen soon 12" 130,000 * = JAKEBOLTS - 90,000 PSI TENSILE VECTOR BOLTS : MATERIAL 78,000 PSI EMBEDMENT AND FAILURE LOAD FOR” NOMINAL [FAILURE LOAD [eALCULATED [RECOMMENDED hau DEPTH unum DEPTH 4.0" 5.0” ees ee 108,000 Sea] TiS te ** = VECTOR BOLTS - 78,000 PSI TENSILE 131 ANCHORS 1 S —~ ee LY Vector Anchor Bolts The Heavy Duty Jakebolt is designed to be cast in place during foundation construction. / UNISORB CAPSULE ANCHOR SYSTEM PRODUCT CODES VECTOR BOLTS DESCRIPTION PRODUCT CODE EMi2 126 450030 EMi2 2x8. 450050 EMI6 5/8X6 480140 Ewe sexe ‘aso120 EMi6 5/810 480130 Mie 50x12 ‘30160 EMi6 5/6 X14 480150 EMa0 9/48. ‘450210 EMa0 3/4 X10 ‘480220 EMa0 3/412 450230 EMa0 34x14 450240 EMa0 3/416 450250 EM20 3/418 450280 Mas 15/16 x12 450810 M24 15/16 X14 450420 Mas 15/1616 50440 M24 18/16X 18 «450430 EMa0 1-316 12 450510 M30 13/1614 450530 Eso 13/1618 450520 EMo0 1-311624 450540 EMO6 1-7/16X16 ‘450870 EMS6 1-7/16X26 450680 HEAVY DUTY JAKE BOLTS. DESCRIPTION PRODUCT CODE, 2x6 “420400 sexe 421400 58 x 12 421500 axe ‘422400 34x12 422500 78x6 ‘433400 71x12 423500 1x6 424400 1x12 424500 axe 426400 t1ax2 428500 1472x6 ‘az7400 ae K12 427500 194xe 428400 19012 428500 2x6 420400 2x12 429500 122 CAPSULE ANCHOR SYSTEM DESCRIPTION. PRODUCT CODE CAPSULES - ( Sold in full pkgs only ) 38 10PKG 21038 Giz 10PKG s21012 css 10PKG 21058 ess 10pKG 21034 78 10PKG 521078 e100 10/eKG #21100 C116 5PKG sania PRODUCT CODES [STUD ASSEMBLIES - (Longer stude 3:38 X5-118 s12x612 S8X7518 Soa Ko 78x 10-1/4 100x412, S-114X15 1523038 23012 520088 ‘520004 520078 ‘$3100 Penn DRIVE UNITS - (Straight Shank Type p38 baz ss oe 78 BHi00. pata INTERNALLY THREADED INSERTS. 378 Ld. x32 aR hd aya" 5/8" 1.0. x5" 9/4" LO. x 6-5/8" (Use with complete system) ‘525038, ‘s2s012 525058, ‘s2s078 525100 ‘seria 523114 123 VECTOR ANCHOR BOLTS Vector Anchor Bolts are designed to generate - exceptional holding power. Made of high quality forged steel, vector bolts have a series of angular facets which resolve vertical stress forces into a cone shaped pressure pattern. This unique design greatly increases the contract area between the bolt and grout. The wedge shaped design on the bottom of the bolt transfers the tensile load of the stud into a lateral compressional load in the foundation assuring maximum pull outstrength. ‘The tensile strength of the standard grade bolt is a minimum of 78,000 PSI. Higher strength bolts are available. ‘Vector Anchor Bolts are available in 10 | diameter sizes with lengths from 3" to 40". S FOR VECTOR BOLTS: EXCEPTIONAL HOLDING POWER 124 VECTOR ANCHOR BOLTS 7 (ecu — =F ae 6 MAXIMUM TENSILE STRENGTH . | t ~ —commeretal Grado — he rb ‘ Heavy Duty Grade r ~ Le | 100,000 psi. Tye Mig ASIC DIMENSIONS STANDARD LENGTH L* —m— mm 10 25 20 55 17 180 200 250 300 [ae fa [a [aw fowl fo | o | ao | ae =m — mm 12 w 24 70 19 1S 100 125 150 180 200 230 ae fw [ewig [ae (ele [ase [zl en [er —M— mm 16 40 32 90 24 100 150 200 250 300 360, 400, *© TR HOU aaa neocon e e —M— mm 20 50 40 | 100 30 150, 200 250 300 360 400 460 20 ‘inch e = . ~ a * oe om oe a tod BE, [oe [a [aw Pe [al] or [oe [a0] a2 | te | 0° | a —M— mm 22 | 55] 44 | 115 | 32 || 180 200 | 250 | 300 | 360 | 400 TBR [oe [aw [ave [owe [asl] oe [oe Pao [ze | ve | aoe eM— mm 24 60, 48 | 135 | 36 (250 300 360 400 600 Tapeh [owe | ane| ane [ene [rae] aor | a2 | tee] ae] te] aor | ae | —Em— mm cu 5 60 | 150 | 46 320 400 460 500 600 720 800 —EM— mm 36 90 | 72 180 | 55 400 500 600 720 800 920 FB [ane | ue | ane | z [22r |] aee*| 20 | zat] 20° | aor | a0 —M— mm 42 | 105| 85 | 260 | 65 || 500 | 600 | 720 | 800 | 920 | 1000 TBS [awe [awe | ane frou| 26°| aor | 2a [zee | aor | ao | aoe —M— mm 48 | 120 | 98 260 | 75 720 800 920 1000 aa ‘inch | 7 ae BE, [vm [aur | our [row | 20° |] 20” | oer | ase | aor + Standard Stock Sizes 125 1258, VECTOR BOLT SELECTION & GROUT USE DETAIL, VECTOR BOLT SELECTION & GROUT USE PH12 I6 = H200 M2430 E436

You might also like