You are on page 1of 2

Request for Quotation

Internal Element (Cartridge/Demister)


I.

General Requirement
Cartridge shall able to remove solid particle from the gas stream with efficiency of
99.9 % on 10 micron and larger at flow between 5% and 100 % of design capacity.
The cartridge shall also have element of glass fiber bonded by a phenolic resin or
equivalent filtration material all supported by a suitable stainless steel cage to reduce
water content.
The design of the cartridge shall be such that only the element itself shall require
replacement when blocked. The pressure drop in cartridge for clean condition shall
not exceed 0.1 bar.

II.

Process Data
a. Design Capacity
b. Operating Capacity
c. Operating Pressure
d. Design Pressure
e. Gas Composition

: 330 m3/hr
: 300 m3/hr
: 5-8 bar
: 12 bar
:

Compone
nt
H2S
CO2
N2
C1
C2
C3
i-C4
n-C4
i-C5
n-C5
C6+

Specific Gravity Gas


Gas Compressibiliy Factor
Water Content

III.

Design and Specification

Mole %
0
5.07-7.93
1.19-9.79
77.2479.91
2.56-5.53
1.7-4.37
0.39-0.79
0.42-0.99
0.19-0.27
0.13-0.23
0.25-0.7

: 0.7119-0.7525
: 0.9967-0.9975
: 40 lbs/MMSCF

Sketch of Cartridge Installation is shown in picture bellow. Vendor may


suggest different methods for Cartridge installation as long as internal
cartridge is removable through access opening (manhole/handhole).
Design estimation of pressure vessel internal diameter is 12 with demister
thickness is 3.

IV.

Requirement
Vendor Shall supply detail drawing, datasheet material, and graph of filtration
performance that shows pressure drop, efficiency and particle size.