Professional Documents
Culture Documents
Project Name
Tower Name
Case Name
ZONE
DESCRIPTION
TRAY NUMBER
% OF LOADING
LOADINGS
Vapor Rate
Vapor Density
Vapor Volume
Vapor Viscosity
Liquid Rate
Liquid Density
Liquid Volume
Surface Tension
Liquid Viscosity
Date : 11-Aug-2015
Page : 1
File : CAPITAL GAS-07-08-2015-4 stage Compressi
By :
Revision :
Tray 1
Section_1
100
Tray 2
Section_1
100
Tray 3
Section_1
100
Tray 4
Section_1
100
Tray 5
Section_1
100
kg/hr
kg/m3
m3/s
cP
kg/hr
kg/m3
m3/hr
mN/m
cP
12442
33.838
0.10
0.0098
6703
442.54
15.15
6.01
0.079
12322
33.439
0.10
0.0100
6583
451.09
14.59
6.04
0.082
12239
33.244
0.10
0.0102
6500
459.60
14.14
6.20
0.084
12248
33.225
0.10
0.0103
6509
464.36
14.02
6.27
0.087
12284
33.239
0.10
0.0103
6544
466.38
14.03
6.28
0.088
m
%
%
0.61
1.00
72
18
0.61
1.00
71
17
0.61
1.00
70
16
0.61
1.00
69
16
0.61
1.00
69
16
Downcomer Backup
Downcomer Exit Velocity
m liq
m/s
0.1
0.126
0.1
0.121
0.1
0.118
0.1
0.117
0.1
0.117
mm liq
mm liq
mm Hg
58.2
78.4
2.6
56.7
76.7
2.5
55.2
75.1
2.5
54.7
74.6
2.5
54.8
74.6
2.6
Cf Active Area
Weir Load
Weir Crest
m/s
m3/h/m
m liq
0.09
17.3
0.0
0.09
16.6
0.0
0.08
16.1
0.0
0.08
16.0
0.0
0.08
16.0
0.0
m
m2
m
%
0.950
0.71
0.006
9.91
m
m
m2
1
0.366
0.877
0.34
Tray Spacing
System Factor
Jet Flood
Downcomer Flood
Tower Diameter
Tower Area
Sieve Hole Diameter
Percent Hole Area
Downcomer Width
Downcomer Area
Weir Height
Downcomer Clearance
Active Area
Flow Path Length
|
|
|
m |
m2 |
m |
m |
|
m2
m
Side
TOP
|
|
0.29 |
0.19 |
0.05
0.04
Number of Passes
Flow Path Length
Weir Length
Active Area
|
BOTTOM |
|
0.29 |
0.19 |
|
|
|
Panel A
0.34
0.37
The Sieve Tray results in the KG-TOWER software are provided for general informational purposes only. When internal calculations are performed by Koch-Glitsch,
these internal rating pages may be the same or different from the present results. Please contact Koch-Glitschs Technical Assistance with any questions.
WARNING:
Certain Design issues exist with the current design. Please refer to the RESULTS printout for details.
The information contained herein is the confidential and proprietary property of Koch-Glitsch, LP and/or its affiliates ("Koch-Glitsch"). This information
and any derivatives thereof are the exclusive property of Koch-Glitsch. This information is believed to be accurate and reliable but is not to be construed
as implying any warranty or guarantee of performance. The KG-TOWER(R) Software that generated this report may not be used by or exported
or re-exported to any U.S. embargoed country (currently Cuba, Iran, Syria, Sudan, and North Korea), a national or resident of such countries, or anyone
on the U.S. Treasury Department's list of Specially Designated Nationals. You are solely responsible for compliance with U.S. economic and trade
sanctions. Refer to the License Agreement for additional information.