You are on page 1of 3

PROJECT :

CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Drilled Cast-in-place Pile Design Based on ACI 318-05


DESIGN CRITERIA
1.

ASSUME FIX HEAD CONDITION IF Ldh & Lhk COMPLY WITH THE TENSION DEVELOPMENT. OTHERWISE PINNED AT TOP.

2.

FROM PILE CAP BALANCED LOADS & REACTIONS, DETERMINE MAX SECTION FORCES OF SINGLE PILE, P u, Mu, & Vu.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc'

ksi

VERT. REBAR YIELD STRESS


PILE DIAMETER
PILE LENGTH

fy
D
L

=
=
=

60
24
35

ksi
in
ft

FACTORED AXIAL LOAD

Pu

100

FACTORED MOMENT LOAD

Mu

200

ft-k

Vu =
FACTORED SHEAR LOAD
PILE VERT. REINF.
8
#
SEISMIC DESIGN (ACI 21.10.4) ?
LATERAL REINF. OPTION (0=Spirals, 1=Ties)

20
7
Yes
1

LATERAL REINFORCEMENT

( Ldh =

11

Ties

#
4 @
6
in o.c.
(spacing 3.0 in o.c. at top end of 10.0 ft.)
(IBC/CBC 1810 & ACI 21.10.4)
in

Lhk =

&

14

in )

THE PILE DESIGN IS ADEQUATE.

ANALYSIS
CHECK PILE LIMITATIONS
fc ' =

ksi

D=

24

in

>
>

[Satisfactory]

(IBC 1810.1.1)

MAX( L / 30 , 12 in) [Satisfactory]

2.5

ksi

(IBC 1810.3.2)

CHECK FLEXURAL & AXIAL CAPACITY

where

F
=

=
Ag =

'
C

Ec

, E c 57


0.85 f C' 2 c c
fC
o
o

'
0.85 f C , for c o
s E s , for s y
fS
f y , for s y

Pmax =F [ 0.85 fc' (Ag - Ast) + fy Ast] =

2 0.85 f

'
C

, E s 29000ksi
,

for 0 c o

743.26 kips., (at max axial load, ACI 318-05, Sec. 10.3.6.2)

0.8 , ACI 318-05, Sec. 10.3.6.1 or 10.3.6.2


0.65 (ACI 318-05, Sec.9.3.2.2)
Ast =
452 in2.

>
4.80

in2.

Pu

[Satisfactory]

(cont'd)
1000

Pn (kips)

800
600

Pn (k)

400
200

743

AT MAXIMUM LOAD
AT 0 % TENSION

743
639

108
161

AT 25 % TENSION
AT 50 % TENSION
ATt = 0.002

527
432

198
215

288
282

222
224

AT BALANCED CONDITION
ATt = 0.005

0
0

50

100

150

200

250

-200

96

234

AT FLEXURE ONLY

174

AT TENSION ONLY

-259

-400

Mn (ft-k)
a = Cb1 =
=

10

in (at balanced strain condition, ACI 10.3.2)

0.7 + ( t - 0.002 ) (200 / 3), for Spiral

0.65 + ( t - 0.002 ) (250 / 3), for Ties


Cb = d

where

c / (c + s)

in

20.1 in, (ACI 7.7.1)

Mn = 0.9 n =

174

Mn =

ft-kips @ Pu =

234

12

0.656

(ACI 318-05, Fig. R9.3.2)

t=

0.002069

1 =

0.85

ft-kips @ Pn = 0, (ACI 318-05, Sec. 9.3.2) ,&

max

0.08 (ACI 318-05, Section 10.9)

min

0.005 (IBC, Section 1810.1.2.2)

provd

c=

0.003

( ACI 318-05, Sec. 10.2.7.3 )

t,max = 0.004, (ACI 318-05, Sec. 10.3.5)

>

100 kips

Mu

[Satisfactory]

0.011
[Satisfactory]

CHECK SHEAR CAPACITY

Vn = (Vs + Vc) =
=

where

kips, (ACI 318-05 Sec. 11.1.1)

>

Vu
[Satisfactory]
0.75 (ACI 318-05 Sec. 9.3.2.3)

A0 =

316 in2.

Vc =

2 (fc') A0 =

Vs =

MIN (d fy Av / s , 8 (fc')0.5A0) =

smax

smin

s =

86

Av =

0.5

34.6

0.40

fy =

in2.

10.5 (IBC 06 , Section 1810.1.2.2)

sprovd

1
s,provd =

<

requird 0.02 e d b f y
, 8d b , 6 in
L dh MAX
'
provided

fc

where

14
db

required / provided
e

=
=
=

in
[Satisfactory]

0.12 fc' / fyt = 0.006

ksi

kips, (ACI 318-05 Sec. 11.5.7.2 & 11.5.7.9)

0.008 [Satisfactory]

(ACI 318-05 Sec. 21.10.4.4 & 21.4.4.1)

DETERMINE FIX HEAD CONDITION

Lhk

60

kips, (ACI 318-05 Sec. 11.3.1, 11.3.1.3)


80.3

=
12 db
11
in
(ACI 318-05 12.5.2)

in, (ACI 318-05, Fig. R12.5)


0.875 in
=
1.0
1.0
0.7

0.8

Mn (ft-kips)

AT COMPRESSION ONLY

( A s,reqd / A s,provd , ACI 318, 12.2.5)

(1.2 for epoxy-coated, ACI 318-05 12.2.4)


(normal weight)
(#11 or smaller, cover > 2.5" & side >2.0",
ACI 318-05 12.5.3)

You might also like