1.4 Layer of Protection
1.4 Layer of Protection
4 Layer of Protection
DR. AA
EMERGENCY RESPONSE
CONTAINMENT
RELIEF
SIS
ALARMS
BPCS
A
U
T
O
M
A
T
I
O
N
RELIEF SYSTEM
SAFETY INTERLOCK
SYSTEM
ALARM SYSTEM
BASIC PROCESS
CONTROL SYSTEM
Four
independent
protection
layers (IPL)
PROCESS
Control Strategy
Feedback Control
Single-loop feedback
Overcoming disturbances
Cascade
Feed forward
Ratio
Constraints
Split-range, override/select control
Multivariable
multi-loop
Decoupling
Multivariable control
5
F1
F2
T1
T2
Sensor
System
Controller
T
F
TC
TT
Major components
- Sensor & Transmitter
- Cables
- Controller
- Actuator
6
Fin
Cascade Control
Lsp
Fin
Fout
LC
LT
Fout
LC
LT
FT
RSP
FC
Feedforward
To Steam
Users
To Steam Users
LC
FT
FF
LT
LT
Make-up
Water
Feedback-only must
absorb the variations in
steam usage by feedback
action only.
Make-up
Water
FT
To Steam
Users
FF
LC
LT
Make-up Water
FT
FC
Larger Valve
Smaller Valve
Total Flowrate
One with a small control valve and one with a large control
valve
At low flow rates, the large valve is closed and the small valve
provides accurate flow control.
At large flow rates, both valve are open.
10
pH
0.002
0.01
Override/Select Control
Override/Select control uses LS and HS action to
change which controller is applied to the
manipulated variable.
Override/Select control uses select action to
switch between manipulated variables using the
same control objective.
12
LS
TC
TT
RSP
FC
FT
Fuel
Flue
Gas
Process
Fluid
13
DPC
LS
AC
RSP
FC
FT
AT
Controller
output
Cold
feed
>
TY
Selects the
largest of all
inputs
>
TC
Measured value
to PID
controller
TY
T1
T2
15
Inferential control
Predictive control
Adaptive control
Multivariable control
16
- HIGH
- MEDIUM
- LOW
18
Example
The automation strategy is usually simple, for example,
If L123 < L123min; then, reduce fuel to zero
steam
PC
How do we
automate this SIS
when PC is adjusting
the valve?
LC
water
fuel
20
fc = fail closed
steam
15 psig
PC
LC
LS
water
fuel
fc
fc
SIS
100
Shown as box
in drawing with
details elsewhere
22
The SIF saves us from hazards, but can shutdown the plant
for false reasons, e.g., instrument failure.
T100
Better
performance,
more expensive
T100
T101
T102
1 out of 1
must indicate
failure
2 out of 3
must indicate
failure
False
shutdown
Failure on
demand
5 x 10-3
5 x 10-3
2.5 x 10-6
2.5 x 10-6
Same variable,
multiple sensors!
23
i/o
sensors
SIS system
i/o
i/o
sensors
SIS and Alarms
associated with SIS
24
Underpressure
Also, we must protect against unexpected vacuum!
25
26
Process
27
No external power
required
self acting
Rupture disk / burst
diaphragm must be
replaced after opening
Process
To effluent handling
28
29
Is it local or remotely
displayed? Why?
The display is local to
reduce cost, because
we do not have to
respond immediately
to a failed disk - the
situation is not
hazardous.
30
underpressure
32
F1
T
5
34
F1
35
The level is
unstable; it must
be controlled.
F1
36
Alarms
Where could
we use alarms
in the flash process?
F1
37
F1
LAH
LAL
Too much light key
could result in a
large economic
loss
AAH
38
F1
39
The drum can be isolated with the control valves; pressure relief is
required.
F1
40
41