Tanggal
06/08/201
4
07/08/201
4
08/08/201
4
09/08/201
4
10/08/201
4
Rata-rata
Syn Gas
Cooling Water
T. In
T. Out
T. In
T. Out
123,2
42
71329,6917
35,7
43,5
123,4
48
71329,0083
35,8
43,7
123,3
44
71329,02
35,9
43,9
123,4
48
71328,8806
36,1
44,3
123,2
43
71328,4909
36
44,1
123,3
45
71329,0183
35,9
43,9
Rate
Operas
i
96,34
619492,4
95,3
619492,7
94,39
619492,6
95,3
619492,8
94,91
619492,5
619492,6
95,248
Mengetahui,
Process Engineer
Teguh Widodo
Badge No. 11-2524
78
Spesifikasi Alat
Heat Exchanger 116-C Unit Sintesa Amonia
Ammonia Plant Pusri-II Palembang
Nama alat
Jenis alat
Type
: BFU
No.Tube
: 254
: 19 mm
Panjang tube
: 4264 mm
Ketebalan tube
: 2,1 mm
Pitch
: 25 mm
: 736 mm
Number of passes
Fluida
shell
: Two
tube
: Two
shell
: Cooling Water
Tube
: Syn Gas
Mengetahui,
Process Engineer
Teguh Widodo
Badge No. 11-2524
79
Kondisi Aktual
Heat Exchanger 116-C Unit Sintesa Amonia
Ammonia Plant Pusri-II Palembang
Keterangan
Shell Side
Tube Side
(Cooling Water)
(Syn Gas)
281.000
35525,65
79,02
123,3
64,62
45
viskositas (lb/fthr)
2,299
0,0284
1,3077
0,3491
0,09479
Parameter
Mengetahui,
Process Engineer
Teguh Widodo
Badge No. 11-2524
Kondisi Desain
Heat Exchanger 116-C Unit Sintesa Amonia
80
Tube Side
(Cooling Water)
(Syn Gas)
178.000
35525,65
59,4
296,406
84,6
114,354
viskositas (lb/fthr)
2,299
0,0284
1,3077
0,3491
0,09479
Parameter
Mengetahui,
Process Engineer
Teguh Widodo
Badge No. 11-2524
81