This document provides technical specifications for a 20 kVA UPS (uninterruptible power supply) system. It lists details like the input and output voltages and frequencies, battery type and autonomy time, front panel display and controls, environmental specifications, and certifications. The UPS is available in single or three-phase configurations from 1 kVA up to 300 kVA, and can maintain an output of +/- 1% voltage stability and +/- 0.1% frequency stability.
This document provides technical specifications for a 20 kVA UPS (uninterruptible power supply) system. It lists details like the input and output voltages and frequencies, battery type and autonomy time, front panel display and controls, environmental specifications, and certifications. The UPS is available in single or three-phase configurations from 1 kVA up to 300 kVA, and can maintain an output of +/- 1% voltage stability and +/- 0.1% frequency stability.
This document provides technical specifications for a 20 kVA UPS (uninterruptible power supply) system. It lists details like the input and output voltages and frequencies, battery type and autonomy time, front panel display and controls, environmental specifications, and certifications. The UPS is available in single or three-phase configurations from 1 kVA up to 300 kVA, and can maintain an output of +/- 1% voltage stability and +/- 0.1% frequency stability.
MODELS Power (kVA) INPUT Nominal Voltage Emergency voltage Voltage tolerance Frequency OUTPUT Nominal Voltage Static stability Dynamic stability Frequency Waveform Power factor Overload capability Efficiency at 100% load BATTERIES Type Autonomy Time (full load) BY-PASS Input Voltage USER INTERFACE Front panel Output instruments Protection Alarm Remote indication ENVIRONMENTAL Noise Operating temperature Relative humidity Protection rating Colour MTBF ( batteries exc.) MTBT Standards Quality
Three-phase / Single phase
From 1 kVA to 300 kVA From 115 to 690 VAC From 115 to 690 VAC +/- 10% 50/60 Hz +/-10% From 220 to 690 VAC +/- 1% +/- 5% 50 or 60 Hz +/- 0,1% Sinusoidal (maximum distortion 3%THD) > 0,9 125% for 120; 150% for 30 0,90 Lead, flooded and VRLA AGM / GEL; NiCd, From 5 minutes to 24 hours - on request From 220 VAC to 690 VAC Graphical mimic with LEDs Voltmeter, ammeter, frequencymeter Overload, short circuit, overtemperature, out of voltage protection, battery on discharge protection Power failure, overload, over-temperature A volt-free changeover contact for common fault alarm < 55 dB (A) 1mt -5C / +45C < 95% non condensing From IP 20 to IP 55 on request RAL 7035 or 7032 or 9010 on request 50.000 hours 1 hour IEC EN 62040-1 62040-2 62040-3 ISO 9001:2000