Professional Documents
Culture Documents
5'
5'
11 3/4"
5'
6'-10 1/4"
1'-3"
5 1/2"
1'-4 3/4"
3'-0 7/8"
1'-3"
7'
1'-3"
3'-11 1/8"
2"
1'-4 3/4"
1 3/4"
11"
2'-6"
Construction
1 Bar Shelf
Scale: 34" = 1'0"
Notes:
Build from 1x
Use 1x for trim
Glue and Screw
See TD/ATD with questions
Trim
2 Bar Shelf
Scale: 34" = 1'0"
Backing
3 Bar Shelf
Scale: 34" = 1'0"
Backing Notes:
Use luan for backing
Glue and staple
C
University of Alabama
42nd Street
Bar Shelf
DIR: Stacy Alley
DES: Andy Fitch
ATD: Brandon R Smith
00/00
SCALE: As Printed
A
SP1
SP1
Unit P4, P6
Scale: 1" = 1'0"
Notes:
Build 2: Label P4, P6
Standard Hollywood flat construction
Glue and screw
Build from 1x, face with Luan
See TD/ATD with questions
SP2
SP2
2
C
Unit P1, P9
Scale: 1" = 1'0"
Notes:
Build 2: Label P1, P9
Standard Hollywood flat construction
Glue and Screw
Build from 1x, face with Luan
See TD/ATD with questions
University of Alabama
42nd Street
False Proscenium
DIR: Stacy Alley
DES: Andy Fitch
ATD: Brandon R Smith
02/03
SCALE: As Printed
SP3
SP3
SP4
SP4
SP5
SP5
Unit P2, P8
Scale: 1" = 1'0"
Notes:
Build 2: Label P2, P8
Standard Hollywood flat construction
Glue and Screw
Build from 1x, face with Luan
See TD/ATD with questions
Unit P5
Scale: 1" = 1'0"
Notes:
Build 1: Label P5
Standard Hollywood flat construction
Glue and Screw
Build from 1x, face with Luan
See TD/ATD with questions
Unit P3, P7
Scale: 1" = 1'0"
Notes:
Build 2: Label P3, P7
Standard Hollywood flat construction
Glue and Screw
Build from 1x, face with Luan
See TD/ATD with questions
University of Alabama
42nd Street
False Proscenium
DIR: Stacy Alley
DES: Andy Fitch
ATD: Brandon R Smith
03/03
SCALE: As Printed
HP1
HP1
Molding Detail
Scale: 3" = 1'0"
Notes:
Face with Luan
See TD/ATD with questions
H1 Facing
Scale: 1" = 1'0"
H3 Facing
Scale: 1" = 1'0"
C
University of Alabama
42nd Street
Hotel Unit Flats
DIR: Stacy Alley
DES: Andy Fitch
ATD: Brandon R Smith
00/00
SCALE: As Printed
HP1
HP1
Notes:
1
8" thick plate steel
Use 81" bit for screw holes
Sink screws to be flush
See TD/ATD with questions
1
C
Hotel Flat H2
Scale: 1" = 1'0"
Notes:
See ATD for facing info
Build from 1x, Rip to 2 58"
See TD/ATD with questions
University of Alabama
42nd Street
Hotel Unit Flats
DIR: Stacy Alley
DES: Andy Fitch
ATD: Brandon R Smith
00/00
SCALE: As Printed
HP3
HP2
A
HP1
HP4
HP4
HP3
Hotel Flat H1
Scale: 1" = 1'0"
Notes:
See ATD for facing info
Build from 1x, Rip to 2 58"
See TD/ATD with questions
HP2
HP1
C
University of Alabama
42nd Street
Hotel Unit Flats
DIR: Stacy Alley
DES: Andy Fitch
ATD: Brandon R Smith
00/00
SCALE: As Printed
HP3
A
HP2
HP1
HP4
HP4
HP3
Hotel Flat H3
Scale: 1" = 1'0"
Notes:
See ATD for facing info
Build from 1x, Rip to 2 58"
See TD/ATD with questions
HP2
HP1
C
University of Alabama
42nd Street
Hotel Unit Flats
DIR: Stacy Alley
DES: Andy Fitch
ATD: Brandon R Smith
00/00
SCALE: As Printed
A
Notes:
BUILD 2
Standard Hollywood construction
Face with Luan
Glue and Staple
See TD/ATD with questions
Construction Overview
Scale: 1" = 1'0"
Notes:
Pull molding from storage
Door molding is 34" MDF
See TD/ATD with questions
C
University of Alabama
42nd Street
Hotel Unit Overview
Hotel Molding
Scale: 1" = 1'0"
00/00
SCALE: As Printed