Shearfix Punching Shear Reinforcement

Guidance for Completion of BS EN 1992 (EC2) Design Sheet


Design Software
Ancon Shearfix design software is available to download free from www.ancon.co.uk. The software will check your application for
punching shear requirement and provide details of any required Shearfix rails including a DXF file detailing the arrangement. The software
carries out designs to both BS EN 1992 (Eurocode 2) and BS 8110.
Ancon is pleased to offer a punching shear reinforcement design service. To ensure we receive all necessary design information Ancon requires
the design information for each column to be compiled together. Unfortunately we are unable to offer a Shearfix design service based upon
sets of separate drawings; the design sheet on the following page has been developed for the transfer of this information. Following receipt of
the design information for each application you would like us to consider, calculation sheets will be returned to you detailing the required
Shearfix rails.
Ancon can carry out designs to either BS 8110 or BS EN 1992 (Eurocode 2). A design information sheet is available for each code; please
complete the appropriate sheet.
Notes for BS EN 1992 (Eurocode 2) Designs
Loads
Please note, that whilst there is a column on the design sheet for moments, these cannot be used in all applications. For different column
types the following options are avaliable for specifying loads:

Column Type

Load Specification Options for EC2

Interior

Specify VEd with set factor of 1.15 or

Specify Veff

Edge

Specify VEd with set factor of 1.4

or

Specify Veff

n/a

Corner

Specify VEd with set factor of 1.5

or

Specify Veff

n/a

Specify Veff

n/a

Re-entrant Corner

n/a

or

Specify VEd and Moments

N
z

Mz

Reinforcement in direction z

Direction of Moments

My

y
z

z
y

Reinforcement in direction y

Rail Arrangements
Ancon provides solutions in either orthogonal or radial layouts, therefore please remember to indicate your preference on the design sheet. In the
absence of this information we will provide what we consider to be the best / most economical solution for each case which will inevitably mean a
mix of the two in the overall design.
Reinforcement
Please indicate the reinforcement diameter and spacing on the sheet. Where additional reinforcement is being used, please provide both sizes i.e.
for main reinforcement of 16mm @ 200mm spacings plus additional reinforcement of 20mm @ 200mm spacings, please write 16 + 20 @ 200.
Edge Distances
Edge distances are restricted to three times the effective depth where the effective depth is slab depth - top cover - ( T1 +2 T2 ).

Ancon Building Products, President Way, President Park, Sheffield S4 7UR, United Kingdom.
Tel: +44 (0) 114 275 5224, Fax: +44 (0) 276 8543
Email: info@ancon.co.uk Web: www.ancon.co.uk

Page 1 of____

Shearfix Punching Shear Reinforcement to BS EN 1992 (EC2) - Design Information


Please refer to the additional guidance sheet before completing this form.
Project name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Project address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

..................................................

Tel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Email . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Slab depth

Concrete cover top

. . . . . . . . . mm

Rail Layout (tick one)

Concrete cover bottom

. . . . . . . . . mm

Radial

. . . . . . . . . . . . . . . mm

Concrete strength C . . . . . . /. . . . . . . .

Best solution
per column

Note: Refer to supplementary sheet for information on moments and possible load combinations.

Orthogonal

OR
Your Column
Reference

Column
Type (A1, A2...)
(see below)

Column
Dimension
(mm)
yxz

Edge
Distance
(mm)
d*
c*

VEd (kN)
Ultimate Load
ULS

Moments**
kNm
Mz
My

Reinforcement
in direction
y
bar spacing

Veff (kN)
Effective Load
ULS

Reinforcement
in direction
z
bar spacing

Voids (mm)
(Please supply drawings
to clarify positions of voids)
Size
Position
vy
vz
y
z

* Maximum 3 x effective depth.


** Mz moments act in the columns y direction i.e. horizontally across the columns when orientated as shown below. Please refer to the guidance sheet for more information. If left blank, standard factors will be applied.

Column Type

z
y

A3
z

y
edge

d*

A4

d*
edge

d*

A6

A7

c*

A5

Void Position and Size


y

A8
c*

edge

c*

Faxback to +44 (0) 114 276 8543 or email: tech@ancon.co.uk