You are on page 1of 2

Analoginput

EL3356

RunLED
Steadystate
Selfcalibration
ErrorDiff.

PowerLED
Measure
Selftest
ErrorRef.

+UD

+UREF

UD
Powercontact
+UV

UREF

Uv
Powercontact0V

+Uv

Shield

Shield

ThesupplyvoltageUVhas
tobesuppliedfroman
externalsource,max.12V,
e.g.EL9510.

Topview

Contactassembly

EL3356|1channelpreciseloadcellanalysis(resistor
bridge),16bit
TheanalogEL3356inputterminalenablesdirectconnectionofaresistorbridgeorloadcellina4or6wireconnectiontechnology.The
ratiobetweenthebridgevoltageUDandthesupplyvoltageUREFisdeterminedsimultaneouslyintheinputcircuitandthefinalloadvalueis
calculatedasaprocessvalueonthebasisofthesettingsintheterminal.Withautomaticselfcalibration(canbedeactivated)anddynamic
filterstheterminalwithmeasuringcyclesof10mscanbeusedforslowweighingswithhighprecision.
Technicaldata

EL3356|ES3356

Numberofinputs

2,for1resistorbridgeinfullbridge
technology

Powersupply

viatheEbus

Technology

resistorbridge,straingauge

Distributedclocks

MeasuringrangeUD

max.25+25mVratedvoltage

MeasuringrangeUREF

max.12+12Vratedvoltage

Internalresistance

>200k(UREF),>1M(UD)

Inputfilterlimitfrequency

10kHzlowpass(3dB)

Conversiontime

10250ms,configurable,max.
100samples/s

Conversionrate

1004samples/s(10250ms
conversiontime)

PowersupplyUV

upto12Vfrompowercontacts,
dependentonsensor

Resolution

16bit,32bitpresentation

Measuringerror

<0,01%forthecalculatedload
valueinrelationtothefinalload
valuewitha12Vfeedand24mV
bridgevoltage(hencenominal
straingaugecharacteristicvalueof
2mV/V),selfcalibrationactive,50
Hzfilteractive

Currentconsumptionpowercontacts

dependsonstraingaugesupply,
min.1mA

CurrentconsumptionEbus

typ.210mA

Supportednominalsensitivity

all,resolutionofparameter:0.01
V/V
recommended:0.54mV/V

Specialfeatures

selfcalibration,quadruple

averager,dynamicfilters
Weight

approx.60g

Operating/storagetemperature

0+55C/25+85C

Relativehumidity

95%,nocondensation

Vibration/shockresistance

conformstoEN6006826/EN
60068227

EMCimmunity/emission

conformstoEN6100062/EN
6100064

Protect.class/installationpos.

IP20/variable

Pluggablewiring

forallESxxxxterminals

Relatedproducts

EL33560010

1channelpreciseloadcellanalysis
(resistorbridge),24bit