You are on page 1of 1

SEDL Scheme for RO Reject Water

UPL Limited
Designed Capacity :25 KLD
Total MVR Power Required : 13.11 kW

RO REJECT WATER CONCENTRATION

NCGs Out
0.3 kg/h
1.20 m/h
45.5 kPa
79.0 C
79.0 C (Sat.)
2,641.4 kJ/kg

RO Reject Water
1,250.0 kg/h
1.25 m/h
1.25 t/h
35.0 C
1.20% TDM

1,150.0 kg/h
45.5 kPa
89.0 C
79.0 C (Sat.)
2,661.3 kJ/kg

40

30

20

Power Required:13.11 kW

Compressed Vapors
1,159.6 kg/h
4,104.27 m/h
1.16 t/h
45.5 kPa
79.0 C (Sat.)
2,641.4 kJ/kg

1,150.0 kg/h
38.6 kPa
75.0 C
75.0 C (Sat.)
2,634.6 kJ/kg

20-0

210-1

Vapors
1,150.0 kg/h
1.15 t/h
38.6 kPa
75.0 C
75.0 C (Sat.)
2,634.6 kJ/kg

HS: 100 m2
HTC: 1868 W/m2.K

210

1,159.6 kg/h
79.0 C

HS: 10 m2
HTC: 1266 W/m2.K
0

8
1

270

1,250.0 kg/h
35.0 C

300

100

1,250.0 kg/h
73.0 C

Reject
100.0 kg/h
0.10 m/h
0.10 t/h
75.0 C
15.00% TDM

8
9

320

Condensate Out
1,149.7 kg/h
10 m2
38.0 C
1266 W/m2.K

310
0

1,149.7 kg/h
79.0 C

240
9

250

UPL Limited

BALANCED

SPRAY ENGINEERING DEVICES LIMITED

Spray Engineering Devices Limited, India

Dinesh Saini

MVR Evaporator

9/30/2015 1:04:41 PM