You are on page 1of 1

REV #

TEST/ALARM DISABLE RETURN


+12

IC5

C48

ECO #415

10/31/91

ECO #437 CHANGED R90 FROM 75.0K TO 66.5K, C50=.22uF ADDED


IN SERIES TO ELIMINATE TURBO DC OFFSET

8A

8/31/93

ECO #781

NO CHANGES ON THIS SHEET

ECO #939

ADDED R98A

8B

4/21/94

10

10/18/96

NO CHG THIS SHT


ALARMOSC

24.9K,1%,1/4W
2

12

+12
4
R75

1
2

1M,5%,1/4W

J1

J1

R106
R107

1 Q24
2N2907

20K,5%,1/4W

1
Q25
2N2907

2
10

20K,5%,1/4W
R140

R105

47K,5%,1/4W

Q27
2N2222
1

R103

J14

OC AC FAIL

Q32
2N2222

J14

CC AC FAIL

J14

DB-9 GROUND

J14

DB-9 GROUND

J14

UPS SHUTDOWN

J14

RS-232 AC FAIL

Q33
2N2222
1

R104

R141

J14

3
2

20K,5%,1/4W

Q28
2N2222

R101

20-OHM,5%,1/4W

47K,5%,1/4W

R139

680K,5%,1/4W

12UNFILT
R143

IC10

11

+12

200K,5%,1/4W
1

R113

CC LOW BATTERY

5
12UNFILT

200K,5%,1/4W

14

COMP

721-0003

7
+12

INVDISBL

IC10
14

C41
0.01UF,100V,5%

D39

R137

2
D17
1N4148

C16

1M,5%,1/4W

47K,5%,1/4W

+12

721-0003

30.1K,1%,1/4W

1N4148

12

Q12
2N22221

IC10

14

IC3

1M,5%,1/4W

1.0UF,50V

R135

R46

+12

14

6.8M,5%,1/4W

IC6
14
C VCC
10
OUT
IN GND
7

R72
1

26.1K,1%,1/4W

R47

13

C44

100K,5%,1/4W

12

R134

2M,5%,1/4W

R138

0.22UF,50V,5%

R73

CLAMP

Q29
2N2907

Q9
2N2907

R115

3
1

14

D31
1N4148

1N4148

1
2
350-4001 D30

10

IC10

13

215K,1%,1/4W

+5

NO CHANGES ON THIS SHEET

+12

D18

+12

D46

2
1N4148

IC10

14

+12
R108

1N4148

D15
R74

IC4

D22
1N4148

IC2

+12

14

200K,5%,1/4W

R114
1

20K,5%,1/4W

C702

14

9/6/91

+12

0.01UF,50V,20%,CER

IC10

R133

7
C15
.1uF,50V,5%,POLY

+12

2K,5%,1/4W

+12

#412 AND ECO #413


WAS 5.62K, IS NOW 10K TO REDUCE TURBO DC OFFSET.
WAS 69.8K, IS NOW 75.0K FOR BETTER TURBO NULL.
WAS 1M, IS NOW 200K TO DESENSITIZE TURBO.

V+

R131
1

V-

30.1K,1%,1/4W

1
2

ALARMOSC

ECO
R93
R90
R97

+12

8/30/91

11

R130

5.62K,1%,1/4W

1
Q11
2N2907

R71

R129

C25

R69

22UF,16V

CHANGE R64
TO 24.9K
ON 400

SW1

33.2K,1%,1/4W

R64

2.26K,1%,1/4W

6.81K,1%,1/4W

10.0K,1%,1/4W

R68
ACFAIL

33.2K,1%,1/4W

+5

R70

12UNFILT

10.0K,1%,1/4W

C26
2

470K,5%,1/4W

24.9K,1%,1/4W

12

0.01UF,100V,5%
LOW BAT WARNING
OPEN = 2 MIN
CLOSED = 5 MIN

12UNFILT

14

1N4148

SHUTDOWN

5,6

+12
6

+12

ECO #391 AND ECO #394


R138 WAS 33K IS NOW 24.9K, C44 WAS .1uF IS NOW .22uF
TO MAKE CURRENT LIMIT WORK WITH STABLE +12.

BZ1

REVISION

7/17/91

R45

100K,5%,1/4W

390-0004

IC3

D35

14

1
1

1N4148

+12
D20

.1uF,50V,5%,POLY

ACFAIL

DATE

0.01UF,50V,20%,CER

1N4148

4.7K,5%,1/4W

C29

8
SW1

10

C14

IC5

0.01UF,100V,5%

SWITCH CLOSED =
BEEPER DELAY

R128

14

R44

J2

+12

ALARM DISABLE J2

100K,5%,1/4W

NOTES:
1) ALL DIODES 1N4148

R102
1K,5%,1/4W

ACFAIL

D32

1N4148

C42
2

R109
1

R111
1

100K,5%,1/4W

20K,5%,1/4W

100K,5%,1/4W

2
1
22UF,16V

R110

2
C43

D34

3
Q23
2N2222

1N4148
1N4148

SHUTDOWN

22UF,16V

D33

1
Q26
2N2907
3

DELETE ON 200VA/280VA

AMERICAN POWER CONVERSION


DESCRIPTION

SHEET

SB207 CIRCUIT BOARD SCHEMATIC


PRODUCT

MINI 250/400 BACK-UPS


DATE

3/18/91

2 OF 3

APCC PART #

BY

0S-207
SCALE

ESM

DWG

REV

640-0207F

12

You might also like