You are on page 1of 2

Multisim Convergence Assistant Summary Report

Convergence Assistant Summary Report


Outcome:
The simulation error was corrected successfully.
Changes Made:
-Shunt resistance from analog nodes to ground (RSHUNT) was changed to 10
0000000

Multisim Convergence Assistant Log


Step 1: Verifying Error Scenario
...completed.
Step 2: Setting parameter Integration Method (METHOD) to Gear
Simulating...
...completed. Simulation error still occurs.
Step 3: Setting parameter Initial Conditions to Set To Zero
Simulating...
...completed. Simulation error still occurs.
Step 4: Setting parameter Maximum Timestep (TMAX) to 1.0000e-004
Simulating...
...completed. Simulation error still occurs.
Step 5: Setting parameter Maximum Timestep (TMAX) to 1.0000e-003
Simulating...
...completed. Simulation error still occurs.
Step 6: Setting parameter Relative error tolerance (RELTOL) to 1.0000e-002
Simulating...
...completed. Simulation error still occurs.
Step 7: Setting parameter Shunt resistance from analog nodes to ground (RSHUNT)
to 1000000000
Simulating...
...completed. Simulation error still occurs.
Step 8: Setting parameter Shunt resistance from analog nodes to ground (RSHUNT)
to 100000000
Simulating...
...completed. Simulation error fixed.
Step 9: Attempting rollback of Initial Conditions to Automatically Determine
Simulating...
...Rollback successful.
Step 10: Attempting rollback of Maximum Timestep (TMAX) to 1.0000e-005
Simulating...
...Rollback successful.
Step 11: Attempting rollback of Relative error tolerance (RELTOL) to 1.0000e-003

Simulating...
...Rollback successful.
Step 12: Attempting rollback of Shunt resistance from analog nodes to ground (RS
HUNT) to 1.0000e+012
Simulating...
...Error recurred - rollback unsuccessful.
Step 13: Restoring value of Shunt resistance from analog nodes to ground (RSHUNT
) to 100000000
Step 14: Attempting rollback of Integration Method (METHOD) to Trapezoidal
Simulating...
...Rollback successful.
Convergence Assistant completed successfully.