Product Model: ZT-032

Foreword

Dear Customers:
Hello!
Thanks for purchasing our automatic vacuum laminating machine. Our company is a
screen maintenance equipment professional supplier who forms an integration of
research and development, production, sale, after sales service. Our main products are
as follows: Vacuum Laminating Machine, LCD Separator Machine, Autoclave, OCA Film
Laminating Machine, Pulse Hot Press Machine etc. equipment for screen maintenance
and IC Polisher maintenance equipment.

Please carefully read the product instruction before you use this machine. Please
abide by safety notes. Set technology parameter and operate this machine strictly
according to the specification. Please contact us for any question, we will do our best
to solve these questions for you! Please properly take care of every item instruction
and relative technology documents for reference any time!

The products specifications and technology parameters in this brochure are only for reference.
There wont be notice for any updates. This brochure is only for using guidance. All statements
and information in this brochure are not guaranteed. Final explanation right belongs to our company.

Contents

Part 1
Part 2
Part 3
Part 4
Part 5
Part 6
Part 7
Part 8
Part 9
Part 10
Part 11

Foreword------------------------------------------------------------------------1
Contents-------------------------------------------------------------------------2
Vacuum Laminating Machine Back Components Diagram----------3
Product Main Features-------------------------------------------------------4
Laminating Machine Operation Procedure------------------------------5
Vacuum Laminating Machine Installation Diagram-------------------6
Operation Interface Instruction--------------------------------------------7
Notes-----------------------------------------------------------------------------8
Faults and solutions-----------------------------------------------------------9
Attached Included Accessories List---------------------------------------10
After Sales Service-------------------------------------------------------------11

Vacuum Laminating Machine Back Components Diagram

Air pressure regulating valve

Vacuum cylinder regulating


valve (up, down)
Up and down press mold
regulating valve

Power triangle plug,


connect 220v/110v power

Air pipe connector, connect


air compressor
air pipe connector, connect
vacuum pump

Triangle plug,
connect vacuum pump
Machine Brand

Product Main Features

Model:
Weight
Wattage:
Volume:
Voltage:
Laminating speed:
Suitable screen size:
Materials:
Operation system:
Operation interface:

ZT-032
40KG (without vacuum pump)
1000w (with vacuum pump)
53*45*40cm
220v/110v
can be customized
below 10.5cun
Aluminum
PLC+ autonomous operation system
4.3cun

Laminating Machine Operation Procedure


ZT-032 Automatic Vacuum Laminating Machine Diagram
1.Power on, reset the machine to original situation.

Operation interface
Vacuum Gauge
Temperature
controller

Pressure Gauge
Precise pressure
regulating valve

2.Adjust each parameter correctly, including vacuum


gauge, temperature controller, precise pressure
regulating valve, operation interface etc..
3.Put the counter pointed screen on the machine
under mold tray. Put silicone pad on the tray.

Start
Eye protection
organic glass
Reset

4.Press the two green buttons at the same time to start.


The machine will automatically return to original
situation after laminating.
5. Take out the screen. It is done.

Vacuum Laminating Machine Installation Diagram

Vacuum Laminating Machine


Air pipe which connects
air compressor

Connect 220v/110v power


Air compressor
Vacuum pipe which connects
vacuum pump
Vacuum pump

Power patch board

Operation Interface Instruction


Note: Please use triangle socket and properly
connect ground wire for your safety and
machine safety

1.Manual operation: Exchange between manual model and


automatic model by touch.
2.Air cylinder proceeding: Under tray goes forward and backward
by touch.
3.Vaccum cylinder goes down: cylinder goes down (or up) by touch.
4.Break vacuum to open cylinder: Input air to vacuum cylinder to
open it.
5.Press mold goes down: Inside press board goes down.
6.Open vacuum: Vacuum pump works. Extract air in the vacuum
cylinder until it is vacuum situation.
7.Reset: Let the machine recover by touching reset button.
8.Down pressing time: Usually set 150-200ms (namely 15-20s).
9.Opening vacuum time: set 25ms (namely 2.5s).
10. Parameters setting: Inside parameters have been set in the
factory, and they usually do not need to be adjusted.

Notes
1.It is advised that try several time to make sure the machine functions
well before starting working in order to reduce unnecessary loss.
2.Set the operation interface parameters to reasonable value, usually
subject to the values set in factory. Please do not random set these
parameters and call our after sales engineer if any problem occurs.
3.Let operation interface be automatic situation when it is working
normally.
4.Connect all power and connectors according to the regulations. Refer to
7 page for detailed instruction.
5.Do not put your hand in any functioning part in case of injury.
6.Please do not open the back cover without the engineers guidance if
case of electric shock.
7.Please put the machine in dry and clean environment.

Faults and solutions


Fault

Diagram

Solution

Fault

Diagram

Solution

The vacuum
pump does not
work or keeps
working without
stop.

Open the
electricity box to
find the relay as
showed. Pull down
the relay by band
directly to
exchange. Notice
the model and
voltage of the relay.

The press
mold does
not press
down.

If the value in
vacuum gauge
can not reach
the one set, then
you can reduce
the pre-set
vacuum value.

The vacuum
cylinder does not
go down.

the back air


cylinder regulating
valve closed or the
airflow too small.
Then you should
re-regulate it.
(you can contact
our after sale
technician by
video.)

The machine
does not
work.
(Namely
Powered
normally, but
the
components
do not
function.)

Check the
precise
regulating valve
to see if it is
closed or has
been set to
minimum. Then
re-regulate it.

Attached Included Accessories List


Accessary

Quantity

Vacuum pump

Inside hexagon wrench

Air pipe connector

Using instruction

Standard power line

Silicone pad

After Sales Service


Notes about warranty:
1.The manufacturer should ensure the product quality according to the industrial regulations and ensure the
the machine can function normally.
2.The manufacturer offers the operation and technology training for free. And all problems occurring in the
process of installation and using will be carefully solved. The subsequent free technology inquiry and support
are included.
3.From the day when the delivery is confirmed, the free warranty term is 12 months if it is no human damage.
and it can be guaranteed all lifetime, mainly including inside electron component.
(Easily broken components outside are not included)
4.Customers should use and maintain the machine according to the manufacturer training to improve the
lifecycle. Customers should undertake the responsibility if the damage is caused by improper operation,
but we can offer the maintenance service with charge of relative electron component.